Sec. 49-552. - PVC pipe and fittings in buildings containing two or more occupancies.

Occupancies shall be classified in accordance with the 2006 International Building Code. (a) In buildings containing Group R-1 and/or Group R-2 occupancies mixed with Group A-2, B, M, I-4 day care and/or S-2 parking garages, PVC may be used for soil, waste and vent piping in the Group R-1 and/or Group R-2 occupancies provided all the following conditions are met: (1) The R-1 and/or R-2 occupancy is of Type V construction as defined in the 2006 International Building Code section 602.5. (2) Is a maximum four levels in height. (3) The A-2, B, M, I-4 day care and/or S-2 parking garage is of Type I-A construction and is located beneath the R-1 and/or R-2 occupancy. (4) The A-2, B, M, I-4 day care and/or S-2 parking garages is separated from the R-1 or R-2 occupancy by a minimum three hour horizontal assembly. (5) The entire building is protected throughout with an approved automatic fire sprinkler system. (b) Cast iron pipe shall be installed throughout the occupancies located below the three-hour horizontal separation. The cast iron pipe shall extend a minimum of 12 inches above the three-hour horizontal assembly. (c) In buildings containing Group R-1 and/or Group R-2 occupancies mixed with Group U private garages, PVC may be used for soil, waste and vent piping throughout all occupancies provided all the following conditions are met: (1) The entire building is of Type V construction. (2) The building is a maximum four levels in height. (3) The Group U private garages are located on the lowest level. (4) The Group U private garages are exclusively for the parking of private motor vehicles for the occupants of the Group R-1 or R-2 occupancies. (5) The entire building is protected throughout with an approved automatic fire sprinkler system.

(Ord. No. 40524, § 1, 10-20-15)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.