8-1-1: - DEFINITIONS
The following words, terms, and phrases, when used in this Chapter, shall have the meanings ascribed to them in this Section, unless otherwise expressly stated: AIR GAP (AG): A physical separation between the free-flowing discharge end of a potable water supply line and an open or non-pressure receiving vessel. An air gap must be at least twice the diameter of the supply pipe measured vertically above the overflow rim of the receiving vessel, and in no event less than 1 inch (2.54 cm), to serve as backflow protection. This method is required for backflow protection of sewage or reclaimed water. AUXILIARY WATER SUPPLY: Any source of water other than from the City public water system or the potable water system of a public utility regulated by the Arizona Corporation Commission, including but not limited to, water from a well, spring, river, stream, or canal. BACKFLOW: The reversal of flow in the public water system such that water or mixtures of water and other liquids, gases, or other substances are introduced into the public water system from any source other than the public water system. BACKFLOW PREVENTION ASSEMBLY: An assembly used to prevent backflow into a potable water system. The types of backflow prevention assemblies are: Double Check Valve Backflow Prevention Assembly (DCVA) Pressure Vacuum Breaker Backsiphonage Prevention Assembly (PVB) Reduced Pressure Principle Backflow Prevention Assembly (RPA) Spill-Resistant Pressure Vacuum Breaker Backsiphonage Prevention Assembly (SVB) BACKFLOW PROTECTION: A backflow prevention assembly, air gap, or any combination thereof acting in concert. BACKPRESSURE: Any elevation of pressure in a customer water system, above the supply pressure at the service connection/point of delivery, which might cause or contribute to backflow. Examples of conditions which may cause backflow include use of a pump, elevation of piping, steam pressure, or air pressure, etc. BACKSIPHONAGE: Backflow, which causes a sub-atmospheric pressure condition in a water system. CERTIFIED TESTER: A natural person with a current certification and approval to conduct testing on Backflow Prevention Assemblies by an entity engaged in the business of certifying backflow assembly testers and which is approved by the Water Resources Department. CITY: The City of Mesa, an Arizona Municipal Corporation and political subdivision, of the State of Arizona. COMPLIANCE DUE DATE: The seventh day after of installation of backflow protection or the seventh day after discovery of an installed backflow protection which has not been tested in conformance with this Chapter in the 12 months preceding such discovery. Thereafter, the 1-year anniversary of the most recent compliance due date. CONTAMINATION: Any impairment in the quality of potable water, by sewage, industrial fluids, waste liquids, compounds or other solids, gases, or fluids. CROSS-CONNECTION: Any direct or indirect connection in a customer water system through which it is possible to introduce any substance other than the intended potable water with which the system is supplied, including but not limited to industrial fluids, gas, auxiliary water and wastewater. Bypass arrangements, jumper connections, removable sections, swivel or change-over devices and other temporary or permanent devices through or because of which backflow can occur are cross-connections. A direct cross-connection is a cross-connection which is subject to both backsiphonage and backpressure. An indirect cross-connection is a cross-connection which is subject to backsiphonage only. CUSTOMER: The owner, tenant, trustee, mortgagee, receiver or occupier, whether person, corporation, firm, or municipality, of property which is connected to the public water system, including but not limited to, the person, persons or entity in whose name a City water service account is established and that is responsible for payment of the water rates, fees and charges. CUSTOMER WATER SYSTEM: A privately-owned potable water system, or any portion thereof, lying between the service connection and the point of use. This system includes all pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to convey, store or utilize the potable water. DEGREE OF HAZARD: The level of actual or potential risk (either a non-health hazard or health hazard) derived from the assessment of the substances which may come into a customer water system through a cross-connection, as set forth in Section 8-1-4. DEPARTMENT: The City Water Resources Department, or any successor identified by the City which is responsible for enforcing the requirements of this Chapter. DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY (DCVA): A backflow prevention assembly composed of two independently acting, approved check valves, including tightly closing resilient seated shutoff valves, attached at each end of the assembly and fitted with properly located resilient seated test cocks. This assembly is acceptable for use as protection against non-health hazards only. DUAL CHECK DEVICE: Two independent check valves with a vent to the atmosphere. This device is acceptable for use on a non-health hazard or low hazard applications only. These non-testable devices can only be installed on ice makers and non-carbonated beverage dispensers. FIRE SPRINKLER SYSTEM: An integrated system of water piping for fire prevention and suppression, designed in accordance with applicable City Code provisions and standards, and connected to the public water system. HEALTH HAZARD: Contamination to a degree which creates an actual hazard to the public health that may cause illness or death if ingested. NON-HEALTH HAZARD: Pollution to a degree that may affect the color or odor of water but will not cause illness or death if ingested. NON-POTABLE WATER: Water that has not been treated for human consumption in compliance with federal, state and local requirements. NOTICE: A written instrument served by the City, as follows, with time commencing from date of mailing, serving, filing or recording as applicable: (1) By the use of ordinary mail to the last known address of the person to whom it is required to be given; (2) By personal service upon the person or his lawful representative; (3) By filing or recording with a clerk of the superior court or county recorder; or (4) By any means authorized by the Arizona Rules of Civil Procedure. PLUMBING HAZARD: An actual or potential plumbing cross-connection in a customer water system. A plumbing hazard may present either a Health or non-health hazard. POINT OF USE: The point within a customer water system where potable water is used. POINT OF USE PROTECTION: Any backflow prevention assembly or means designed to prevent backflow commensurate with the degree of hazard that is installed within a customer water system, typically located at the water supply line for equipment or appliances. POLLUTION: The presence of any foreign substance (organic, inorganic or biological) in water which tends to degrade its quality or impair its usefulness to a degree which does not create an actual hazard to the public health, but which does adversely and unreasonably affect such water for domestic use. POTABLE WATER: Water which meets the federal, state and local requirements for human consumption, including drinking, culinary, and other domestic purposes. PRESSURE VACUUM BREAKER ASSEMBLY (PVB): An assembly containing an independently operating internally loaded check valve and an independently operating loaded air inlet valve, located on the discharge side of the check valve, with properly located resilient seated test cocks and tightly closing resilient seated shutoff valves at each end of the assembly. This assembly may only be used to protect against a non-health hazard, or a health hazard under a backsiphonage condition. PUBLIC WATER SYSTEM: Means all plants, mains, laterals, pipes and other structures owned and/or maintained by the City, through which potable water is treated, supplied and distributed to the public, including wells and well structures, intakes, pumping stations, treatment plants, reservoirs, storage tanks and appurtenances. RECLAIMED WATER: Wastewater treated to the federal, state and local standards for reuse, but which has not been treated to the federal, state and local standards for potable water and human consumption. RECOGNIZED BACKFLOW PREVENTION ASSEMBLY TESTER: A certified tester meeting the requirements of the Department for the annual performance of backflow testing, as set forth in Section 8-1-12 of this Chapter. REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY (RPA): A backflow prevention assembly containing two independently acting approved check valves together with a hydraulically operating, mechanically independent pressure differential relief valve, located between the check valves and at the same time, below the first check valve. The unit shall include properly located resilient seated test cocks and tightly closing resilient seated shutoff valves at each end of the assembly. SERVICE CONNECTION/POINT OF DELIVERY: The downstream end of the water meter, where the city-owned parts of the public water system ends, and a customer water system begins. For unmetered services such as fire lines, the point of delivery is immediately downstream of the valve separating the city-owned parts of the public water system from the unmetered service connection. SERVICE PROTECTION: The backflow protection at the service connection, which protects the public water system from the degree of hazard presented by a customer water system. SINGLE CHECK VALVE: A mechanical device that is drip tight when the inlet pressure is at least one (1) psi (pounds per square inch) and the outlet pressure is zero. The closure element (clapper or poppet) must be internally spring loaded, to promote rapid and positive closure. SPILL RESISTANT PRESSURE VACUUM BREAKER BACKSIPHONAGE PREVENTION ASSEMBLY (SVB): A backflow prevention assembly containing an independently operating internally loaded check valve and independently operating loaded air inlet valve located on the discharge side of the check valve. This assembly cannot be used for backpressure applications. SYSTEM HAZARD: An actual or potential threat to the public water system, from pollution or contamination.
(Ord. No. 5909, § 2, 12-9-24)
Ask a question about Mesa law
Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.