Sec. 13-3009. - Standards for boarding a vacant building.

(a) Except as provided in subsection (c) of this section, if the owner is unable to secure a vacant building by normal means, the owner shall board the vacant building under the following specifications and requirements: (1) All unsecured doorways, windows, or other exterior openings must be covered by wooden structural panels. However, the glazed portion of an otherwise structurally sound door may be replaced or covered by a wooden panel. (2) Wooden structural panels may be installed on the exterior or interior of the opening. (3) The wooden structural panels installed on the exterior of a building must be flat, square, and level, and in a manner accepted as good workmanship. The administrator has the sole discretion to determine if the work was performed in an acceptable manner. (4) Required materials. The wooden structural panels must be used to cover doorways, windows, or other exterior openings. The wooden structural panels must be composed of CDX exterior grade plywood or oriented strand board ("OSB") with a minimum one-half (½) inch nominal (seven-sixteenths ( 7/16 ) inch actual) thickness. The administrator may approve the use of alternate materials. (5) Required fasteners and hardware. All metal fasteners and hardware must be made of stainless steel, galvanized steel, or cadmium plated steel. (6) Required coatings. All exterior materials used to board a vacant building must be painted with a minimum of two (2) coats of exterior grade latex paint that is black, white, the predominant color of the building, or a color approved by the administrator. (7) Approved methods for installing exterior wooden structural panels. a. Wooden structures with wood trim surrounding window and door openings. 1. If there is a sill that extends beyond the face of the building, the bottom of the wooden structural panels must be flush with the sill and the wooden structural panels must extend at least four (4) inches on the top and on each side of the opening. 2. If there is no sill or the sill does not extend beyond the face of the building, the wooden structural panels must and extend at least four (4) inches on the top, bottom, and on each side of the opening. 3. The wooden structural panels must be attached to the building and window by wood screws, lag bolts, or carriage bolts. A washer must be installed between the head of the screw or bolt and the wooden structural panel. If carriage bolts are used that extend into the interior of the building, washers must be used between the nut and the interior surface. 4. Wooden screws and lag bolts must be secured to the structural framing member surrounding the opening. 5. The structural wooden panels must be attached under the following table: Fastener Type | Fastener Spacing Panel span ≤ 4 foot | 4 foot < panel span ≤ 6 foot | ≤ 6 foot < panel span ≤ 8 foot 2½" #6 Wood screws | 16" | 12" | 9" 2½" #8 Wood screws | 16" | 16" | 12" 6. The fasteners must be installed at opposing ends of the wooden structural panels. b. Masonry structures or structures with brick facades with wood trim surrounding window and door openings: 1. If there is a sill that extends beyond the face of the building, the bottom of the wooden structural panels must be flush with the sill and the wooden structural panels must: A. Cover the window or door opening. B. Be flush with the sill. C. Either be set into or be flush with masonry wall or brick facade on the top and both sides of the opening. 2. If there is no sill or the sill does not extend beyond the face of the building, the wooden structural panels must be either set into or be flush with the masonry wall or brick facade on the top, bottom, and on each side of the window opening. 3. The wooden structural panels must be attached to the building by wood screws, lag bolts, or carriage bolts. A washer must be installed between the head of the screw or bolt and the wooden structural panel. If carriage bolts are used that extend into the interior of the building, washers must be used between the nut and the interior surface. 4. Wooden screws and lag bolts must be secured to the structural framing member surrounding the opening. 5. The structural wooden panels must be attached under the following table: Fastener Type | Fastener Spacing Panel span ≤ 4 foot | 4 foot < panel span ≤ 6 foot | ≤ 6 foot < panel span ≤ 8 foot 2½" #6 Wood screws | 16" | 12" | 9" 2½" #8 Wood screws | 16" | 16" | 12" 6. The fasteners must be installed at opposing ends of the wooden structural panels. c. Masonry structures or structures with brick facades with metal trim surrounding window and door openings: 1. If there is a sill that extends beyond the face of the building, the bottom of the wooden structural panels must be flush with the sill and the wooden structural panels must: A. Cover the window or door opening. B. Be flush with the sill. C. Either be set into or be flush with masonry wall or brick facade on the top and both sides of the opening. 2. If there is no sill or the sill does not extend beyond the face of the building, the wooden structural panels must be either set into or flush with the masonry wall or brick facade on the top, bottom, and on each side of the opening. 3. The wooden structural panels must be attached to the metal trim by metal screws, lag bolts, or carriage bolts. A washer must be installed between the head of the screw or bolt and the wooden structural panel. If carriage bolts are used that extend into the interior of the building, washers must be used between the nut and the interior surface. 4. Metal screws and lag bolts must be secured to the metal structure used to frame the opening. 5. The structural wooden panels must be attached under the following table: Fastener Type | Fastener Spacing Panel span ≤ 4 foot | 4 foot < panel span ≤ 6 foot | ≤ 6 foot < panel span ≤ 8 foot 2½" #6 Wood screws | 16" | 12" | 9" 2½" #8 Wood screws | 16" | 16" | 12" 6. The fasteners must be installed at opposing ends of the wooden structural panels. d. Masonry structures or structures with brick facades with no trim surrounding windows. 1. A wooden frame constructed of with two-inch by four-inch nominal dimensional lumber must be installed around the perimeter of the opening. 2. The wooden frame must be secured to the masonry wall or brick facade with lag bolts and vibration-resistant anchors having a minimum ultimate withdrawal capacity of four hundred ninety (490) pounds. 3. The wooden structural panels must be attached to the wooden frame using wood screws. 4. The structural wooden panels must be attached under the following table: Fastener Type | Fastener Spacing Panel span ≤ 4 foot | 4 foot < panel span ≤ 6 foot | ≤ 6 foot < panel span ≤ 8 foot 2½" #6 Wood screws | 16" | 12" | 9" 2½" #8 Wood screws | 16" | 16" | 12" 5. The fasteners must be installed at opposing ends of the wooden structural panels. e. The administrator may approve the use of blocks, clips, or other special hardware items or alternate methods for installing wooden structural panels. (8) All broken glass and any other loose material must be removed from the opening before the wooden structural panels are installed. (9) Exterior access to floor areas above the first floor, such as fire escapes and ladders, must be either: a. Removed up to the second floor level or to a height of thirteen (13) feet above the ground, whichever is lesser. b. Secured to the satisfaction of the administrator. (10) Fascia signs, overhanging signs, roof signs, and all other appurtenances, such as sun visors or awnings must be removed if they are in a dangerous condition or could create such a condition. (11) All loose or defective materials, trim, or structural elements on the exterior of the building must be removed. (12) Any condition which may become a hazard or danger to the public must be corrected. (b) The owner of a boarded vacant building shall post the premises. (1) One (1) or more signs must be posted at or near each entrance to the building and on fences or walls, as appropriate. (2) The signs must remain posted until the building is either lawfully occupied or demolished. (3) The signs must contain the following information: DO NOT ENTER It is a misdemeanor to enter or occupy this building or premises or to remove or deface this notice. Trespassers will be prosecuted. (4) The lettering of the sign must be at least a forty-eight-point font type size. (c) Instead of boarding a building in the manner specified by subsection (a) of this section, the administrator may allow the owner to secure the vacant building in a manner in which the administrator determines adequately prevents unauthorized entry or vandalism.

(Ord. No. 025929, § 1, 8-31-2004)

Ask a question about Corpus Christi law

Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.