Sanitation and sterilization procedures.
Springfield, Ill., City Code § 95.708
in effect§ 95.708. - Sanitation and sterilization procedures.
(a) All body art establishments must have an autoclave onsite. All other forms of sterilization are prohibited. All non-single-use, nondisposable instruments used for body art shall be cleaned thoroughly after each use by scrubbing with an appropriate soap or disinfectant solution and hot water or by following the manufacturer's instructions, to remove blood and tissue residue, and shall be placed in an ultrasonic unit also operated in accordance with manufacturer's instructions
(b) After being cleaned, all nondisposable instruments used for body art shall be packed individually in peel-packs and subsequently sterilized (see 95.708(3) [subsection (c)]. All peel-packs shall contain either a sterilizer or internal temperature indicator. Peel-packs must be dated with an expiration date not to exceed six months.
(c) All cleaned, nondisposable instruments used for body art shall be sterilized in a steam autoclave. The sterilizer shall be used, cleaned, and maintained according to manufacturer's instruction. A copy of the manufacturer's recommended procedures for the operation of the sterilization unit must be available for inspection by the department. Sterile equipment may not be used if the package had been breached or after the expiration date without first repacking and resterilizing. Sterilizers shall be located away from work stations or areas frequented by the public. If the body art establishment uses only single-use, disposable instruments and products, and uses sterile supplies, an autoclave shall not be required.
(d) Each holder of a permit to operate a body art establishment shall demonstrate that the sterilizer used is capable of attaining sterilization by monthly spore destruction tests. These tests shall be verified through an independent laboratory. The permit shall not be issued or renewed until documentation of the sterilizer's ability to destroy spores is received by the department. These test records shall be retained by the operator for a period of three years and made available to the department upon request.
(e) All reusable needles used in tattooing and cosmetic tattooing shall be cleaned and sterilized prior to use and stored in peel-packs. After sterilization, the instruments used for tattooing/body piercing shall be stored in a dry, clean cabinet or other tightly covered container reserved for the storage of such instruments.
(f) All instruments used for tattooing/body piercing shall remain stored in sterile packages until just prior to the performance of a body art procedure. When assembling instruments used for body art procedures, the operator shall wear disposable medical gloves and use medically recognized techniques to ensure that the instruments and gloves are not contaminated.
(g) All inks, dyes, pigments, needles, and equipment shall be specifically manufactured for performing body art procedures and shall be used according to manufacturer's instructions. The mixing of approved inks, dyes, or pigments or their dilution with potable water is acceptable. Any other dilution outside of the manufacturers recommendations must be approved by the department prior to use. Immediately before a tattoo is applied, the quantity of the dye to be used shall be transferred from the dye bottle and placed into single-use paper cups or plastic cups. Upon completion of the tattoo, these single cups or caps and their contents shall be discarded.
(Ord. No. 131-03-04, § 2, 3-2-04)