§ 9-18 — Amendments to the 2024 International Residential Code

Code of the City of Glendale, Arizona (Supp. No. 115: codified through Ordinance No. O26-19, adopted April 14, 2026) · Glendale City Code § 9-18

Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/d4a8c8c9-e606-47ea-8219-5d9eb41b781f

Sec. 9-18. - Amendments to the 2024 International Residential Code.

The International Residential Code, 2024 Edition is amended in the following respects: Section R101.1 Title is amended to read as follows: These provisions shall be known as the Residential Code for One- and Two-family Dwellings of Glendale, Arizona, and shall be cited as such and will be referred to herein as "this code." Chapter 1. Administration is amended by the deletion of Sections R102 through R114. For the administration of this code, see the 2024 International Building Code and related amendments. Section R201.4, Terms Not Defined is amended by adding to the end of this subsection: Mirriam-Webster's Unabridged Dictionary of the English Language shall be considered as providing ordinarily accepted meanings. Section R202, Definitions, FIRE SEPARATION DISTANCE, revise the last sentence to read as follows: The distance shall be measured at a right angle from the exterior face of the foundation. Section R202, Definitions, GRAYWATER. Revise this definition to read as follows: Wastewater that has been collected separately from a sewage flow and that originates from a clothes washer or a bathroom tub, shower or sink, but that does not include wastewater from a kitchen sink, dishwasher or toilet. Section R301, Design Criteria is amended by adding this subsection: R301.1.5 Lot Corner Identification. In construction applications where legally surveyed lot corner identification markers are not readily verifiable or are missing, the building official, when deemed necessary, shall require lot boundary markers to be surveyed and permanently identified in accordance with State law at the owner's or applicant's expense. The survey shall be executed by a registrant licensed to do such work by the Arizona State Board of Technical Registration. Table R301.2(1) is amended to read as follows: GROUND SNOW LOAD | WIND DESIGN | SEISMIC DESIGN CATEGORY | SUBJECT TO DAMAGE FROM | WINTER DESIGN TEMP | ICE BARRIER UNDERLAYMENT REQUIRED | FLOOD HAZARDS | AIR FREEZING INDEX | MEAN ANNUAL TEMP SPEED (mph) | Topographic effects | Weathering | Frost line depth | Termite N/A | 115 mph (ultimate) 89 mph (ASD) | None | B | Negligible | N/A | Moderate to Heavy | 32° F | No | FEMA | N/A | 72.6° F Table R301.5 Minimum Uniformly Distributed Live Loads is amended with the following values: Habitable attics and attics served with fixed stairs 40 psf Sleeping areas 40 psf Section R302.2, Townhouses is amended by adding this sentence: No plumbing, mechanical, electrical, piping, or other services in any form are allowed to traverse from one side to the other side of the wall or walls separating townhouse units. Section R302.2.6, Townhouses, Structural independence is amended by deleting Exceptions 5 and 6. Section R308.1 is deleted it its entirety and replaced with the following: R308.1 Address Numbers. Property owners shall obtain and display on the residence, the correct building number or numbers as assigned to such property(ies) by the Planning Department or functional equivalent in accordance with established street assignment policy, prior to final inspection and /or issuance of a certificate of occupancy. The address numbers shall be of a durable material, permanently attached to the building and must be readily distinguished and readable from the nearest paved public/common roadway fronting that property. The size of the address numbers shall comply with the city's adopted fire code and its amendments. Section R309.1 Townhouses automatic sprinkler systems. Revise this section to read as follows: Other than where preempted by Arizona State Law, an automatic sprinkler system shall be installed in townhouses. Exception: An automatic sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic sprinkler system installed. Section R309.1.1 Design and installation. Automatic sprinkler systems shall be designed and installed in accordance with NFPA 13D. Section R309.2 One- and two-family dwellings automatic sprinkler systems. In accordance with A.R.S. § 9-807, delete this section in its entirety. In accordance with A.R.S. § 9-461, accessory dwelling units shall not be required to have automatic sprinkler systems. Section R310.2.2 Smoke Alarms. Alterations, repairs and additions; add the following to the list of Exceptions: 3. Swimming pools. 4. Electrical panel replacements. 5. Covered patios and shade structures (porches or decks) 6. Detached garages or other detached accessory structures. This does not exempt Accessory Dwelling Units. 7. Photovoltaic solar systems. Section R317.6, Electric vehicle (EV) charging receptacle outlets and systems. Amend this section to read as follows: In attached garages, provide a minimum of one EV-capable receptacle outlet, not more than 48 inches above and not less than 18 inches above the floor. This installation shall include a junction box with cover and a continuous raceway to the electrical distribution equipment (panelboard). The installed raceway shall be sized and rated to supply a minimum 50-amp circuit capacity. The electrical distribution equipment shall have sufficient dedicated space and spare electrical capacity for a 50-amp circuit breaker. The electrical outlet (junction box) and the electrical distribution equipment directory shall be marked: "For future electric vehicle supply equipment (EVSE)." The EV-capable receptacle outlet shall be provided in addition to the general use receptacle outlets required by Section 3901.9. All components shall be installed in compliance with the National Electrical Code. Exception. Garage additions and garage remodels. Electric vehicle charging systems shall be installed in accordance with the National Electrical Code. Electric vehicle charging equipment shall be listed and labeled in accordance with UL 2202. Electric vehicle supply equipment shall be listed and labeled in accordance with UL 2594. Section R318.1, Means of Egress is amended by adding the following sentences: The means of egress from dwelling units or sleeping rooms shall not lead through other sleeping rooms, toilet rooms or bathrooms. Section R319.4, Area Wells is amended by adding the following: An area well shall not be located beneath an emergency escape and rescue opening. A protective grate shall be provided over all area wells. The grate shall comply with Section R319.4.4 and shall be designed for a minimum uniformly distributed live load of 40 pounds per square foot. Section R319.4.4 Bars, grilles, covers and screens is amended by adding the following sentence: The dwelling shall be equipped with smoke alarms installed in accordance with Section R310. Section R325.8 Required heating is amended to read as follows: R325.8 Required heating and cooling. Every dwelling unit shall be provided with a heating system capable of maintaining a temperature of not less than 70°F; and a cooling system capable of maintaining a temperature no greater than 82°F (if cooled by air conditioning) or 86°F (if cooled by evaporative cooling); at a point 3 feet (914 mm) above the floor and 2 feet (610 mm) from exterior walls in habitable rooms. The installation of one or more portable space heaters or portable space coolers shall not be used to achieve compliance with this code section. Section R401.4, Soil Tests is amended by adding the following sentence: A soils test and geotechnical evaluation report shall be required for all new buildings governed by this code. Section R403.1.3, Footing and Stem Wall Reinforcing is amended by adding Seismic Design Categories B and C to all seismic design requirements listed in this section. Section R403.1.3 is amended by adding the following subsection: Section R403.1.3.7 Foundation Ties. When an addition is constructed, the new foundation shall be tied to the existing foundation by installing two (2) No. 4 dowel bars, minimum 12 inches long. These shall be embedded a minimum of 6 inches into the existing footing. Section R403.1.4 Minimum Depth is amended by revising 12 inches to 18 inches, unless otherwise recommended by a geotechnical evaluation report. Section R403.4.1 Crushed Stone Footings is deleted in its entirety. Section R403.5 Crushed Stone Footings for Cast-In-Place Foundations is deleted in its entirety. Section R502.9 is amended by adding the following subsection: R502.9.1 Framing Connections. Framing details for bearing walls and posts shall be such that all components are tied together with positive connections to transmit wind uplift forces from the roof to the foundation. Nails loaded in withdrawal by such forces shall not be considered as positive connections. Approved metal framing anchors shall be provided at the top and bottom of every other stud of a wood-frame bearing wall, except where structural panel sheathing is nailed directly to the studs, top plate and bottom plate in accordance with Table R602.3(1). Floor-to-floor connections shall have approved metal strap ties at a maximum of 48 inches on center, except where justified by an engineered analysis that bears the seal of a registered design professional. Each truss, joist and rafter shall be connected to the top plate of the supporting wall with an approved metal framing anchor. The framing anchor shall be of the type which connects to both members of the double top plate. Beams shall be anchored to supporting walls and posts with approved metal framing connectors. Section R502.3.1 Sleeping areas and attic joists is amended to read as follows. Table R502.3.1(1) is deleted. Table R502.3.1(2) shall be used to determine the maximum allowable span of floor joists that support sleeping areas and attics that are accessed by means of a fixed stairway in accordance with Section R318.7 provided that the design live load does not exceed 40 pounds per square foot and the design dead load does not exceed 20 pounds per square foot. The allowable span of ceiling joists that support attics used for limited storage or no storage shall be determined in accordance with Section R802.5. Section R602.10 Wall Bracing is amended by adding the following: For buildings that are two or more stories in height, the empirical design provisions for wall bracing in this section shall not be used. An engineered design shall be provided to include both gravity and lateral load calculations. The project drawings and engineering calculations shall bear the seal of a registered design professional. Section R606.1.1, Professional Registration Not Required is revised to read as follows: Masonry shall be designed in accordance with the requirements of this section and shall be reinforced in accordance with Figure R606.11.3. Such masonry shall support only a roof and shall be limited to 10 feet in height and shall not require an engineered design. Masonry construction not meeting these limits shall require drawings and engineering calculations bearing the seal of a registered design professional. Section R606.12 Seismic requirements is revised to read as follows: All new masonry elements shall meet the minimum reinforcing requirements of Sections R606.12.2.2.3, R606.12.2.3.2 and R606.12.2.3.3. These requirements shall not apply to glass unit masonry conforming to Section R607, anchored masonry veneer conforming to Section R703.8 or adhered masonry veneer conforming to Section R703.12. Section R608.1 General is amended by revising the last sentence to read: Project drawings, details, calculations and specifications are required to bear the seal of a registered design professional. Section R610.1 General is amended by revising the last sentence to read: Project drawings, details, calculations and specifications are required to bear the seal of a registered design professional. Section R802.8 Lateral Support is amended to read as follows: Floor joists, rafters and ceiling joists shall be provided with lateral support at points of bearing to prevent rotation. Where lateral support is provided by solid wood blocking, 1X nominal lumber shall not be allowed. Section R802.8.1 Bridging. The first sentence is revised to read as follows: Floor joists, rafters and ceiling joists shall be supported by nominal 2 x solid blocking, diagonal bridging (wood or metal) or a continuous 1-inch by 3-inch wood strip nailed across the rafters or ceiling joists at intervals not exceeding 8 feet. Section N1101.4, Above Code Programs, add the following subsection: N1101.4.1 RESNET Testing & Inspection Protocol. The Residential Energy Services Network (RESNET) Mortgage Industry National Home Energy Rating System Standards (MINHERS) for third party testing and inspections shall be deemed to meet the requirements of sections N1102.5.1, N1102.5.1.2 and N1103.3.7 and shall meet the following conditions: 1. Third Party Testing & Inspections shall be completed by RESNET certified Raters or Rating Field Inspectors and shall be subject to RESNET Quality Assurance Field Review Procedures. 2. Sampling in accordance with Chapter 6 of the MINHERS Standards shall be performed by Raters or Rating Field Inspectors Working under a RESNET Accredited Sampling Provider. 3. Third Party Testing is required for the following items: a. N1102.5.1 — Building Envelope — Thermal Air Barrier Checklist b. N1102.5.1.2 — Testing — Air Leakage Rate c. N1103.3.7 — Sealing — Duct Tightness d. Any other testing and inspections required under the code. 4. Alternate testing and inspection programs and protocols shall be allowed when approved by the Building Official. IRC Table N1102.5.1.1, Air Barrier, Air Sealing and Insulation Installation, revise the criteria for "rim joists" as follows: Delete the statement, "The junctions of the rim board to the sill plate and the rim board and the subfloor shall be air sealed." Section N1104.2, Interior lighting controls. Delete this section in its entirety. Section N1104.3, Exterior lighting controls. Delete this section in its entirety. Section M1411.9, Condensate disposal, add the following: Condensate drain piping shall not terminate over sidewalks, asphalt, concrete, walking surfaces or similar surfaces. All condensate drain piping shall terminate in an approved location as determined by the building official or his representative. Section M1413 Evaporative Cooling Equipment, add the following subsection: Section M1413.2 Water conservation. Evaporative cooling systems shall be provided with a recirculating water system. Any bleed off rate used by the system shall be limited to that recommended by the manufacturer. Once-through evaporative cooling systems using potable water shall not be permitted. Section P2903.2, delete and replace with the following text and table: Section P2903.2 Maximum flow and water consumption. The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table P2903.2. Exception: Replacement of existing fixtures that do not require a permit. TABLE P2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FITTINGS b Plumbing fixture or fixture fitting | Maximum flow rate or quantity b Lavatory faucet | 1.5 gpm at 60 psi Shower head a,c | 2.0 gpm at 80 psi Sink faucet | 1.8 gpm at 60 psi Water closet | 1.28 gallon per flushing cycle d,e For SI: 1 gallon per minute = 3.785 L/m, 1 pound per square inch = 6.895 kPa a A hand-held shower spray shall be considered a shower head. b Consumption tolerances shall be determined from referenced standards. c Shower heads shall comply with all requirements for high-efficiency shower heads in ASME A112.18.1-2020/CSA B125.1 d For a dual-flush water closet, the full-flush volume shall not exceed 1.28 gallons. e A 1.6 gallon per flushing cycle is permitted where a water closet is connected to an existing building's sanitary drainage piping. Section P2904.1, Dwelling Unit Automatic Sprinkler Systems, General is revised to read as follows; delete all remaining sections of P2904. The design and installation of automatic sprinkler systems shall be in accordance with NFPA 13D and the Glendale Municipal Code, Chapter 16, Article III. Partial automatic sprinkler systems shall be permitted to be installed only in buildings not required to be equipped with an automatic sprinkler system. Section P2906.2, Lead Content is amended to read as follows: The lead content in pipe and fittings used in the water supply system shall comply with 40 CFR 143.12(a) as "lead free" as follows: 1. Not contain more than 0.2 percent lead when used with respect to solder and flux; and, 2. Not have more than a weighted average of 0.25 percent lead when used with respect to the wetted surfaces of pipes, pipe fittings, plumbing fittings and fixtures. Section E3404.1 Applicability is amended by adding the following sentence: "For electrical systems not covered by this Code, see the 2023 National Electrical Code." Section E3703.5, Garage branch circuits. This section is amended by adding the following sentence: In addition to the other branch circuits required by this section, the electrical distribution equipment shall have sufficient dedicated space and spare electrical capacity for a 50-amp circuit to supply the EV-capable vehicle outlet required by Section R317.6. Section E3704, Feeder Requirements is amended by adding the following section: E3704.7 Townhouses. Feeders supplying townhouse units shall not pass through or above other townhouse units. Sections E3901.4.2 and E3901.4.3 are amended; delete the text and replace with the following: E3901.4.2 Island and peninsular countertops and work surfaces. At least one receptacle shall be installed at each island and peninsular countertop space with a long dimension of 600 mm (24 in.) or greater and a short dimension of 300 mm (12 in.) or greater. A peninsular countertop is measured from the connected perpendicular wall. E3901.4.3 Receptacle outlet location. Receptacle outlets rendered not readily accessible by appliances fastened in place, appliance garages, sinks, or range tops as covered in the exception to Section E3901.4.1, or appliances occupying assigned spaces shall not be considered as these required outlets. Required receptacle outlets shall be located in one or more of the following: 1. On or above, but not more than 20 inches (508 mm) above, the countertop or work surface. 2. In a countertop using receptacle outlet assemblies listed for the use in countertops. 3. In a work surface using receptacle outlet assemblies listed for use in work surfaces or listed for use in countertops. [210.52(C)(3)] 3901.4.2 Exception: To comply with the following conditions (1) and (2), receptacle outlets shall be permitted to be mounted not more than 12 inches (300 mm) below the countertop or work surface. Receptacles mounted below a countertop or work surface in accordance with this exception shall not be located where the countertop or work surface extends more than 6 inches (150 mm) beyond its support base. 1. Construction for the physically impaired. 2. On island and peninsular countertops or work surfaces where the surface is flat across its entire surface (no backsplashes, dividers, etc.) and there are no means to mount a receptacle within 20 inches (500 mm) above the countertop or work surface, such as an overhead cabinet. Section E3901.9, Basements, garages and accessory buildings is amended to read as follows: Not less than one receptacle outlet, in addition to any provided for specific equipment, shall be installed in each separate unfinished portion of a basement; in each vehicle bay at not less than (18) inches (457 mm) and not more than 5.5 feet (1676 mm) above the floor in attached garages; in each vehicle bay at not less than (18) inches (457 mm) and not more than 5.5 feet (1676 mm) above the floor in detached garages that are provided with electric power and in accessory buildings that are provided with electric power. [210.52(G)(1), (2), and (3)] Section E3908.9, Types of equipment grounding conductors. Amend item #4 as follows: 4. Electrical metallic tubing with an additional equipment grounding conductor. IRC Appendix BC: Accessory Dwelling Units is adopted and amended as follows: APPENDIX BC: ACCESSORY DWELLING UNITS (ADU) SECTION BC101 GENERAL BC101.1 Scope. Accessory dwelling units (ADUs) proposed for existing residential construction shall be in accordance with this appendix and other applicable requirements in this code, and the existing building together with the ADUs shall not exceed the scoping limitations of Section R101.2. BC101.1.1 Prohibited conditions. An ADU shall not be permitted: 1. On the same lot or parcel as a two-family dwelling (duplex) or other multiple-family dwellings. BC101.2 Conditions. ADUs shall be permitted without requiring a change of occupancy where in compliance with all of the following: 1. An ADU shall be permitted within an existing single-family detached dwelling, attached to a single-family dwelling, or in a detached structure that is within the scope of the International Residential Code and in accordance with Arizona Statute § 9-461.18. 2. No more than one attached ADU and one detached ADU shall be permitted per single-family dwelling lot or parcel. 3. No more than one attached ADU and two detached ADUs shall be permitted if the single-family dwelling lot is one acre or more, and only if at least one of the ADUs is recorded as a restricted-affordable dwelling unit in accordance with the Glendale Unified Development Code. 4. An ADU shall not have a separate address from the principal dwelling. 5. ADUs shall be ancillary or secondary to the primary dwelling and may be constructed to equal the square footage of the primary single-family dwelling; but in no case shall the ADU exceed 1,000 square feet. 6. An ADU shall be provided with a separate entrance from that serving the primary dwelling unit from the exterior of the building. 7. The location of a detached ADU shall comply with Section R302. 8. An ADU shall be provided with adequate provisions for electricity, water supply and sewage disposal. SECTION BC102 DEFINITIONS BC102.1 Definitions. The following words and terms shall, for the purposes of this appendix, have the meanings shown herein: ACCESSORY DWELLING UNIT (ADU). An ancillary or secondary living unit to a single-family detached dwelling unit. The ADU shall have a kitchenette or kitchen, bathroom, and sleeping area, and is independently accessed from and located on the same lot as a single-family detached unit, either within the same building as the single-family dwelling or in a detached building. SECTION BC103 ADU PLANNING BC103.1 Design. Except as modified by this section, building planning shall be in accordance with Chapter 3 and building structure shall comply with the International Residential Code. BC103.2 Means of egress. The path of egress travel from an ADU to a public way or to a yard or court that opens to a public way shall be independent of, and not pass through, the primary dwelling unit. BC103.3 Fire separation. For ADUs adjoining the primary dwelling unit, the 1-hour fire-resistance-rated wall and floor assembly provisions of Section R302.3 shall be required. BC103.4 Fire sprinklers. ADUs shall not be required to be provided with automatic fire sprinklers in accordance with Arizona Statute § 9-461.18. SECTION BC104 UTILITIES BC104.1 Heating, ventilation and air-conditioning systems. An ADU shall be provided with: 1. A separate, dedicated heating and cooling system. 2. A separate HVAC thermostat. BC104.2 Electrical systems. An ADU shall be provided with: 1. A separate electric meter and a separate electric service and disconnecting means. 2. Ready access for the occupants to all overcurrent devices protecting the conductors supplying the ADU. BC104.3 Gas piping. An ADU shall be provided with: 1. A separate gas meter and service. 2. Ready access for the occupants to shutoff valves serving the ADU. BC104.4 Water service. An ADU shall be provided with a separate city water meter and water service line. BC104.5 Sewage disposal. An ADU may share a sewer connection with the primary dwelling provided that the sewer line is adequately sized. This shall be proven by calculations submitted with the construction documents. Alternatively, an ADU may be provided with a separate building sewer line and tap.

(Ord. No. O25-51, § 1, 12-9-25)

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.