§ 301.180 — Installation requirements
Minneapolis Code of Ordinances (Supp. No. 73, Update 1: codified through Ordinance No. 2026-020, adopted June 25, 2026) · Minneapolis Code of Ordinances § 301.180
Corpus is an independent public-information project, not the official City of Minneapolis website. Stable reference: corpuslaw.us/code/d5128873-9c40-4400-bf45-8a921ca2b53f
301.180. - Installation requirements.
(A) Installation plans: (1) Before any installation is begun, a floor plan complete with all details of the requirements herein must be submitted to the building official. This plan should show the building outline, location of all mechanical equipment in the building, fans with their CFM capacity, etc. This plan should be accompanied with detailed operation, installation and maintenance manuals prepared by the manufacturer of the proposed dry cleaning machine. (2) Upon receiving written approval of the plans, the installation may be made. (3) Before the machines can be put into operation for use, the installing contractor must arrange for the inspection of the equipment by the building official and receive approval on same. (B) Location: (1) Coin-operated dry cleaning equipment locations must be approved by the building official prior to the installation of machinery. (2) Approval will not be granted for any building occupied in any part as a dwelling. (3) Buildings should be single story structures with concrete floors in good condition. Installations in buildings not having concrete floors may be approved upon application, provided the requirements for proper ventilation, confinement of solvents within the dry cleaning service area and appropriate segregation of all building areas and equipment are installed and maintained to protect health. Complete information about the building and its construction must be included in the plans. (C) General: (1) The solvent shall be stored in closed containers, and should be transferred from the containers in a line free of leaks. All storage facilities for solvent, external from the equipment, must meet the requirements of the fire department. (2) Filter residue and other residues containing solvent shall be disposed of so as not to create a health hazard or nuisance. A covered metal container should be used for temporary storage outside the building. (3) Respiratory protective equipment shall be provided for maintenance personnel and must be kept in good repair and available for immediate use. Chemical cartridge respirators are approved for light solvent concentrations and the wearer should replace the cartridges immediately upon noting odor. (4) A utility fire extinguisher of either the carbon dioxide or dry chemical type must be provided for use against electrical or oil fires. (D) Installation and operation: (1) Generally. Only the front or customer side of the dry cleaning machine should be exposed to the customer area. The working or maintenance portion of the equipment should be separated from the front of the machine by a solid partition. No combustion equipment should be in the service area. Should the door to the service area of the machine itself be from the customer area, it must be so controlled that the emergency fan will go on automatically at any time the access door is opened. (2) Air movement through customer area. As a means of minimizing any solvent build-up in the customer area and also to control any minor solvent leakage, it is required that there be a minimum flow rate from the customer area through the partition as follows: No. of Machines | Minimum Flow Rate Per Machine (CFM) 1—3 ..... | 500 4—8 ..... | 400 9—16 ..... | 375 17 or more ..... | 360 (Example: An eight (8) machine installation requires a minimum continuous exhaust flow rate of 3,200 cfm.) The exhaust ventilation as described above shall be provided on a continuous basis while the store is open for business. The fan wiring shall be such that the dry cleaning equipment cannot be operated unless the fan system is in operation. (3) Emergency fan. It is also required that a general ventilation fan be installed in the back room or maintenance area to be used in case of serious solvent leakage. This fan may be installed in the rear wall and should have a minimum exhaust capacity of one thousand (1,000) cfm per machine when combined with the system in (D)(2). (4) Loading door. The cleaning equipment must be provided with an exhaust system capable of maintaining a minimum of one hundred (100) feet per minute face velocity through the loading door whenever the door is open. The duct work connections from this system must be sealed (soldered or taped) and the discharge stack extended to a minimum height five (5) feet above the roof line. (5) Dike and drain tank. Machines and filter assemblies shall be installed within either a liquidtight concrete dike or pan to contain the solvent should leakage occur. The floor within said dike shall be pitched to drain to a six-inch floor drain or a sump well. Such drain or well shall be connected to an emergency solvent storage tank and this tank shall be of sufficient capacity to hold all of the cleaning solvent contained in one (1) complete system. Storage tanks shall be suitably vented to the exterior and to a minimum of two (2) feet above the roof line. (6) Interlock system. An interlock system must be provided on the machine to prevent the loading door from being opened during the normal cycle. This system may be either electrical or mechanical and so connected that in the event of a power failure the machine fails safe. (7) Make-up air. A supply of tempered make-up air greater than the total volume of air exhausted from the plant must be provided in order to eliminate any negative pressure condition which might develop. Under no condition will machines be allowed to operate where the customer area is not kept above atmospheric pressure. This requirement must be demonstrated to be complied with by proper tests being done by the installing contractor in the presence of the inspector. The make-up air supply fan must be automatically started to operate simultaneously with the fan drawing air from the customer area as outlined above in (2). (8) Operating instructions. A step by step instruction list must be posted in a conspicuous location near the machine for customer use. A competent trained operator must be available or on call as long as the premises are open for business. A telephone number must be listed for emergency assistance. (a) A solvent vapor sensing device within the tumbler is desirable to control the drying cycle and to prevent the removal of the solvent-laden garments. (b) The machine design must be such that essentially no solvent is retained in the cleaned items upon completion of the dry cleaning cycle. A simple performance test which must be satisfied is the lack of any solvent odor in a closed automobile containing a newly cleaned load. (c) It is the responsibility of the proprietor to make certain that clothing which cannot be properly cleaned and dried will not be placed in the machines. (9) The machine should be checked daily and kept in good repair. All maintenance personnel should be familiar with necessary machine repairs and instructed as to the solvent hazards. (10) Solvent control is to be such that under normal operation and use conditions no solvent odor can be detected in the customer area. (11) Only the solvent specified by the equipment manufacturer shall be used. (12) Exhaust ventilation stacks from dry cleaning machines should be located as far as possible from combustion air or drier air intakes. (13) Should any installation require a deviation from any part of these requirements a plan showing in detail the proposed deviation and stating the reason for the change should be submitted to the director of inspections. Written approval from the building official must be received by the installer before commencing any work. (14) Every licensee under the terms of this article shall maintain in full force and effect public liability insurance to indemnify any person against loss or injury in the sum of fifty thousand dollars ($50,000.00) for injury or loss to one (1) person and one hundred thousand dollars ($100,000.00) for each occurrence and fifty thousand dollars ($50,000.00) property damage. (Code 1960, As Amend., § 381.030; 2013-Or-191, § 4, 12-6-13)
Ask a question about Minneapolis law
Corpus searches the Minneapolis sections it holds and shows the ones that match, with their citations. Free, no sign-in.