Sec. 48-581. - Buildings and structures.
All new construction of buildings and structures, including placement of manufactured homes and substantial improvements to existing buildings and structures, that are to be located, in whole or in part, in special flood hazard areas shall meet the following requirements. (1) Be designed (or modified) and constructed to safely resist flood loads. The construction shall provide a complete load path capable of transferring all loads from their point of origin through the load-resisting elements to the foundation. Buildings and structures shall be designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the base flood elevation, including hydrodynamic and hydrostatic loads and the effects of buoyancy. (2) Be constructed by methods and practices that minimize flood damage. (3) Use flood damage-resistant materials below the elevation of the lowest floor. See FEMA Technical Bulletin #2 — Flood Damage-Resistant Materials Requirements and FEMA Technical Bulletin #8 — Corrosion Protection for Metal Connectors in Coastal Areas. (4) Have electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment located at or above the base flood elevation plus 18 inches. Electrical wiring systems are permitted to be located below the elevation of the lowest floor provided they conform to the provisions of the electrical part of this Code for wet locations. If replaced as part of a substantial improvement, electrical systems, equipment and components, and heating, ventilation, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment shall meet the requirements of this section. See FEMA Technical Bulletin #4 - Elevator Installation. (5) As an alternative to subsection (4), electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment are permitted to be located below the elevation of the lowest floor provided that they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of the base flood. (6) In special flood hazard areas other than coastal high hazard areas (Zones A, AE, and AO), meet the specific requirements of division 5. (7) In all coastal high hazard areas (Zone VE), meet the specific requirements of division 6. (8) In a special flood hazard area with more than one designation (Zones A, AE, and AO, floodway, Zones VE), meet the requirements of the most restrictive designation.
(Ord. No. 14-053(sub 1), § 2, 12-18-14)
Ask a question about Wilmington law
Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.