§ 15.36.030 — Noise level reductions standards—25 decibel

Code of Ordinances, City of North Las Vegas, Nevada (Supp. No. 146: codified through legislation passed and adopted on or before August 5, 2026) · North Las Vegas Municipal Code § 15.36.030

Corpus is an independent public-information project, not the official City of North Las Vegas website. Stable reference: corpuslaw.us/code/d57463e1-3f14-4a34-b906-b67fd1e440be

15.36.030 - Noise level reductions standards—25 decibel.

Compliance with the following standards shall be deemed to meet requirements for a minimum noise level reduction (NLR) of twenty-five (25) decibels. A. General. 1. Brick veneer, masonry blocks, or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. 2. At the penetration of exterior walls by pipes, ducts, or conduits, the space between the wall and pipes, ducts, or conduits shall be caulked or filled with mortar. 3. Window and/or through-the-wall ventilation units shall not be used. 4. Through-the-wall/door mailboxes shall not be used. B. Exterior Walls. 1. Exterior walls, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-30. 2. Masonry walls having a surface weight of at least twenty-five (25) pounds per square foot do not require a furred (stud) interior wall. At least one surface of concrete block walls shall be plastered. 3. Stud walls shall be at least four inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco or brick veneer. a. Interior surface of the exterior walls shall be of gypsum board or plaster at least one-half-inch thick, installed on the studs. b. Continuous composition board, plywood, or gypsum board sheathing at least one-half-inch thick shall cover the exterior side of the wall studs behind wood or metal siding. Asphaltic or wood shake shingles or plaster (stucco) are acceptable in lieu of siding. c. Sheathing panels shall be covered on the exterior with overlapping building paper. d. Insulation material at least R-11 shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. C. Windows. 1. Windows, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-28. 2. Glass shall be at least three-sixteenth-inch thick. 3. All operable windows shall be weather-stripped and airtight when closed so as to conform to an air infiltration test not to exceed 0.5 cubic foot per minute per foot of crack length in accordance with ASTM E-283-65-T. 4. Glass of fixed-sash windows shall be sealed in an airtight manner with a nonhardening sealant or a soft elastomer gasket or gasket tape. 5. The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one of the following federal specifications: TT-S-0027, TT-S-00230 or TT-S-00153. 6. Total area of glass shall not exceed twenty (20) percent of total exterior wall area. D. Doors. 1. Doors, other than as described in this section, shall have a laboratory sound transmission class rating of at least STC-26. 2. All exterior side-hinged doors shall be solid-core wood or insulated hollow metal, at least one and two-quarter-inch thick and shall be fully weather-stripped. 3. Exterior sliding doors shall be weather-stripped with an efficient airtight gasket system with performance as specified in subsection (C)(3). The glass in the sliding doors shall be at least three-sixteenth-inch thick. 4. Glass in doors shall be sealed in an airtight nonhardening seal or in a soft elastomer gasket or gasket tape. 5. The perimeter of door frames shall be sealed airtight to the exterior wall construction as described in subsection (C)(5). E. Roofs. 1. Combined roof and ceiling construction other than as described in this section and subsection F shall have a laboratory sound transmission class rating of at least STC-39. This requires an acoustical analysis or test. 2. With an attic or rafter space at least six feet deep, and with a ceiling below, the roof shall consist of one-half inch composition board, plywood or gypsum board sheathing topped by roofing as required. 3. Open beam roof construction shall follow the energy insulation standard method for batt insulation. 4. Skylights shall conform to an STC rating of twenty-eight (28). F. Ceilings. 1. Gypsum board or plaster ceilings at least one-half-inch thick shall be provided where required by subsection (E)(2), above. Ceilings shall be substantially airtight, with a minimum number of penetrations. 2. Glass fiber or mineral wool insulation at least R-19 shall be provided above the ceiling between joists. G. Floors. Openings to any crawl spaces below the floor of the lowest occupied rooms shall not exceed two percent of the floor area of the occupied rooms. H. Ventilation. 1. A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air supply requirements for various uses in occupied rooms without the need to open any windows, doors or other openings to the exterior. The attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least twenty (20) gauge steel, which shall be lined with one-inch thick coated glass fiber, and shall be at least five feet long with one ninety (90) degree bend. 2. Gravity vent openings in attics shall not exceed the code minimum in number and size. 3. All vent ducts (except kitchen and sewer gas ducts) connecting the interior space to the outdoors, excepting domestic range exhaust ducts, shall contain at least a five-foot length of internal sound-absorbing duct lining. Each duct shall be provided with a bend in the duct such that there is no direct line-of-sight through the duct from the venting cross-section to the room-opening cross-section. Duct lining shall be coated fiber duct liner at least one-inch thick. 4. Fireplaces shall be provided with well-fitted dampers.

(Ord. 1030 1 (part), 1991: prior code 13.90.030)

Ask a question about North Las Vegas law

Corpus searches the North Las Vegas sections it holds and shows the ones that match, with their citations. Free, no sign-in.