Sec. 49-620. - Roof drains.

The following provisions shall be followed: (a) Shall conform to ANSI A1 12.21.2. (1) General use strainers shall extend a minimum four inches above the surface of the roof immediately adjacent to the drain and have a minimum inlet area 1½ times the inside diameter of the pipe to which the strainer is connected. (2) Strainers on flat decks, sun decks, parking decks, and similar areas (normally serviced and maintained) may be flat surface type, level with the deck, and shall have an available inlet area minimum two times the area of the pipe to which the strainer is connected. (b) Siphonic roof drains. (1) Shall conform to ASME A1 12.6.9-2005-S and shall be provided with domed strainers. (2) Siphonic roof drain design shall be ASPE No. 45-2007 compliant.

(Ord. No. 40524, § 1, 10-20-15)