§ 82-114 — Depth of bury
Code of the City of Clinton, Mississippi (Supp. No. 4: codified through Ordinance of December 4, 2018 (stale; online content updated December 11, 2019)) · Clinton Code of Ordinances § 82-114
Corpus is an independent public-information project, not the official City of Clinton website. Stable reference: corpuslaw.us/code/d7cae749-f983-459a-8f1a-f1e0405b89e7
Sec. 82-114. - Depth of bury.
The depth of bury established for these pipeline installations should take into consideration a potential increase in ditch depth, resulting from scour, ditch maintenance operations, or the need to increase the capacity of the ditch. Minimum depths are set out below: (1) Transmission pipeline shall have a depth of bury of three feet or more below the surface of normal ground outside of cut, ditch, or fill slope areas. Distribution mains may be placed with a depth of bury of three feet or more below the normal ground line in open or rocky terrain, outside of cut, ditch, or fill slope areas. (2) Lines installed in cut ditches on fairly steep grades shall have a minimum depth of bury of three feet below ditch bottom. (3) The depth of bury below the proposed pavement or riding surface of the road shall be a minimum of four feet. (4) Bury of pipelines carrying transmittants which are flammable, corrosive, explosive, energized, or unstable, particularly if the transmittants are carried at high pressure, must not be reduced below safety requirements recommended by the utility industry involved.
(Ord. of 05-15-2007(2) )
Ask a question about Clinton law
Corpus searches the Clinton sections it holds and shows the ones that match, with their citations. Free, no sign-in.