GENERAL ADU AND JADU REQUIREMENTS.
Oxnard City Code § 16-465.6
in effectSEC. 16-465.6. GENERAL ADU AND JADU REQUIREMENTS.
The following requirements apply to all ADUs and JADUs:
(A) Building and other related codes. Any unit must comply with all applicable building, health and fire codes, except that an ADU or JADU is not required to provide fire sprinklers if sprinklers are not required for the primary dwelling. Additionally, the construction of an ADU shall not trigger a requirement for fire sprinklers to be installed in an existing multifamily dwelling.
(B) Entrances. An attached or internal ADU must have a separate entrance to the ADU, which may also be served by a common entrance with the primary dwelling unit.
(C) Passageways and patio covers. No ADU will be required to provide a new passageway from the ADU to the street. No covered passageway, breezeway, or other type of covered structure that is not fully enclosed and/or conditioned space shall be allowed to connect the primary dwelling unit to a detached ADU. A patio cover attached to an ADU or JADU may be approved that complies with the applicable zone development standards and the square footage shall not be included in the total area for the ADU or JADU.
(D) Manufactured homes and prefabricated homes.
(1) A manufactured home is allowed as an ADU provided that it meets the following requirements:
(a) Meets the definition of ADU in Sec. 16-465.1;
(b) Is designed for use as a single-family dwelling with or without a foundation when connected to the required utilities; and
(c) Includes plumbing, heating, air conditioning, and electrical systems within the home.
(2) A prefabricated or modular home is allowed as an ADU.
(E) Other buildings and structures. Any other building or structure constructed on the lot concurrent with or subsequent to the construction of an ADU under this chapter must comply with all applicable development standards of the zoning code.
(F) Replacing or converting existing structures.
(1) If an existing living area or a detached structure is demolished and replaced with an ADU, an ADU may be constructed in the same location and to the same dimensions as the demolished structure. JADUs shall be limited to conversion of existing or proposed single-family residence including attached garages.
(2) If any portion of an existing structure crosses a property line, the structure may not be converted to or replaced with an ADU.
(G) The local agency shall not deny an application for a permit to create an ADU due to the correction of nonconforming zoning conditions, building code violations, or unpermitted structures that do not present a threat to public health and safety and are not affected by the construction of the accessory dwelling unit.
(Ord. No. 3072)
Source: City of Oxnard, California, City Code (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/oxnard/latest/oxnard_ca/0-0-0-88495Fetched: 11/8/2026