§ 21-342 — Wireless Communication Facilities
Peoria, Arizona, City Code (2026 S-10: Local legislation current through Ord. 2026-20, passed 10-6-26) · Peoria, Ariz., City Code § 21-342
Corpus is an independent public-information project, not the official City of Peoria website. Stable reference: corpuslaw.us/code/db04972a-e850-42cb-a281-485a382686f5
Sec. 21-342. Wireless Communication Facilities.
A. General Requirements. All Wireless Communication Facilities, hereinafter referred to as WCF shall meet each of the following general requirements. 1. WCFs must meet or exceed all current state and federal standards and regulations. 2. WCFs shall be constructed, maintained, and modified in compliance with all adopted Peoria building codes. 3. To ensure compliance with the National Environmental Policy Act (NEPA), a Finding of No Significant Impact (FONSI) issued by the FCC may be required for new WCFs and co-locations. 4. A WCF shall be removed by the provider or the property owner within six (6) months of cessation of use, along with returning the area to its condition prior to the construction of the WCF. 5. A WCF shall not be located within one thousand three hundred and twenty (1,320) feet of a City, State, or Nationally designated historical site. 6. Commercial advertising or signage on the WCF or associated aerial or ground mounted equipment is prohibited. 7. Artificial lighting of a WCF is prohibited, unless required by the Federal Aviation Administration (FAA) or Federal Communications Commission (FCC). 8. WCFs located within a residential zoning district shall be allowed a single microwave dish not in excess of twenty-four (24) inches in diameter. WCF located within non-residential zoning districts shall be allowed a maximum of two (2) microwave dishes which shall not exceed forty-eight (48) inches in diameter per microwave dish unless otherwise approved through a Conditional Use Permit. Such dishes shall be appropriately integrated into concealment efforts to minimize the visual presence of the microwave equipment. 9. Screening of ground mounted equipment shall adhere to the rules and regulations set forth in accordance with the screening provisions found in Section 21-804. 10. Colors and materials of the WCF shall be compatible with the surrounding environment as determined by the City, except as otherwise required by the FAA. 11. One (1) parking space is required per WCF and shall be designed to meet City standards; this includes maneuvering and access. 12. A WCF shall not Alter the Mountain Top Ridge Line as defined in Section 21-641. 13. A WCF located in the right-of-way shall be exempt from the standards contained within this ordinance; however they must comply with all standards and practices established by the Engineering Director including but not limited to all applicable agreements and permits. 14. Co-locations on a utility pole not located in the right-of-way or co-locations located on a public/quasi-public property shall not be required to meet the setback requirements set forth in this section; provided that the ground equipment does not expand the perimeter of the utility facilities. Quasi-public property includes, but is not limited to: a. Schools, to include private, public, charter; b. College or University Campus; c. Power substations; or d. Water pumping plants and storage tanks. B. Development Standards. 1. Permitted Principal Use. a. A Facility shall be deemed a Permitted Principal Use if the following development standards are met: Development Standards | Zoning District | Distance to Residential Property Line | Maximum Heightc | Distance to Nonresidential Property Line | Equipme nt Enclosure | Antenna Distance from Pole | Alternate Design WCFd Permitted Principal Use | Residentialb | > 110% a | 50' | > 50%a | 450 SF | 6%a | Required Non-Residential | > 130% a | 65' a Percentage (%) figures listed shall be based on the height of the pole from adjacent finished grade. Distance is measured from the edge of the tower. b In instances where residential and non-residential uses occupy the same footprint, residential standards shall apply. c If facility WCF is located on or within a height exempt structure per Section 21-302, the height will be measured to the top of the antennae. For ground mounted WCFs height shall be measured from finished grade to the top of the structure including any associated concealment materials. d Fronds, branches, or other methods of concealment shall completely conceal any antennae or other associated Aerial Mounted Equipment. [image omitted; see the official code] b. Rooftop and wall-mounted equipment: 1) Shall follow the height restrictions as listed in the above permitted principal use development standards table; unless otherwise permitted in the height exception provision of Section 21-302. 2) Shall be integrated into the design of the building. 3) Shall be fully screened from public view. c. The co-location of aerial mounted equipment on an existing WCF: 1) Shall not constitute a substantial change unless otherwise identified within Section 21-340.C of the City Code. 2) Shall not be more than an overall height of eighty (80) feet. 3) Shall not otherwise inhibit stealth aesthetics. 2. Permitted Conditional Use. a. Any facility which does not meet the Permitted Principal development standards shall require a Conditional Use Permit, and shall be in accordance with the following development standards: Development Standardsd | Zoning District | Distance to Residential Property Line | Maximum Heightc | Distance to Nonresidential Property Line | Distance Between Non-Alternate Design WCF (Monopole) Permitted Conditional Use | Residentialb | > 110%a | 65' | > 5' | 1,320' Non-Residential | > 130%a | 80' a Percentage (%) figures listed shall be based on the height of the pole from adjacent finished grade. Distance is measured from the edge of the tower. b In instances where residential and non-residential occupy the same footprint, residential standards shall apply. c If facility is located on or within a height exempt structure per Section 21-302, the height will be measured to the top of the antennae. For ground mounted WCFs height shall be measured from finished grade to the top of the structure including any associated concealment materials. d All conditions not specifically identified within this section shall be approved through the Conditional Use Permit process. b. Rooftop and wall-mounted equipment. 1) Shall follow the height restrictions as listed in the above conditional use development standards table; unless otherwise permitted in the height exception provision of Section 21-302. 2) Shall be integrated into the design of the building. 3) Shall be fully screened from public view. c. All monopoles shall be constructed to allow for co-location by other wireless providers. The applicant shall demonstrate that the engineering of the tower and the placement of ground mounted facilities will not preclude other providers. The owner of the proposed tower must certify in writing that the tower will be available for use by other wireless communication providers on an economically reasonable and non-discriminatory basis. d. The co-location of aerial mounted equipment on an existing WCF: 1) Shall not constitute a substantial change unless otherwise identified within Section 21-340.C of the City Code. 2) Shall not be more than an overall height of ninety-five (95) feet. 3) Shall not otherwise inhibit stealth aesthetics. C. Administrative Procedures. 1. Permitted Principal Use. a. All facilities categorized as a permitted principal use are subject to site plan review process as set forth in Section 21-156. 2. Permitted Conditional Use. a. All facilities categorized as a permitted conditional use are subject to the following processes as set forth in Section 21-155 and Section 21-156: 1) Site Plan Review; and 2) Conditional Use Permit. b. The Applicant shall be provided the opportunity to execute a Waiver of Proposition 207 as to only the property leased by the Applicant. In addition to any other grounds the City may have, the City expressly reserves the right to recommend denial of such applications in the event the Applicant elects not to execute a Waiver of Proposition 207. 3. The following criteria shall identify what constitutes a substantial change to a facility. All modifications deemed substantial shall refer to 21-340.B Development Standards: a. An increase in the originally approved WCF height by more than twenty (20) feet or ten percent (10%), whichever amount is greater; b. An increase in the Width more than twenty (20) feet from the Edge of the Tower to the Face of the Antennae. c. An increase in the height of Ground Mounted Equipment by more than ten percent (10%) or ten (10) feet, whichever amount is greater; d. An increase in the Width of a non-tower structure by six (6) feet or more; e. The installation of more than the standard number of Equipment Cabinets needed, not to exceed four (4); f. Excavation outside the current boundaries of the WCF; g. Proposed changes that would defeat the existing concealment elements of the WCF; and, h. Proposed changes that do not comply with prior approval of the WCF unless the non-compliance is within the thresholds outlined in this section. 4. Any proposed facility that does not meet the standards identified within this section shall be prohibited. 5. No facility shall be installed, erected, modified, repaired, or altered without receiving all necessary permit approvals. D. Exemptions from Section 21-155 and Section 21-156. 1. Routine maintenance of a WCF; and, 2. Modifications to a WCF that are not considered a substantial change as specified in Section 21-340.A. 3. WCFs that are owned and operated by a governmental entity for the purposes of public safety or governmental operations. (Ord. No. 98-15, 3-3-98; Ord. No. 98-110, 10-13-98; Ord. No. 98-111, 10-13-98; Ord. No. 07-14, 4-17-07, eff. May 17, 2007; Ord. No. 2017-33, § 176, 6-13-17; Ord. No. 2017-44, § 1(Exhs. B, C), 11-7-17; Ord. No. 2024-19, § 2(Exh. A), 12-17-24)
Ask a question about Peoria law
Corpus searches the Peoria sections it holds and shows the ones that match, with their citations. Free, no sign-in.