§ 4.7 — Drainage and storm sewers

Code of Ordinances of the City of Huntsville, Alabama (Supp. No. 30 (codified through Ord. No. 26-196, adopted March 12, 2026) with enacted ordinances through Ord. No. 26-837 (September 24, 2026) applied from official council minutes and ordinance copies) · Huntsville Code of Ordinances, App. B, art. 4, § 4.7

Corpus is an independent public-information project, not the official City of Huntsville website. Stable reference: corpuslaw.us/code/dba54b15-4abe-4153-a74f-8a76cbbb6558

4.7. - Drainage and storm sewers.

(1) General requirements. A. The planning commission shall not approve any plat of a subdivision which does not make adequate provision for drainage of storm or flood water in accordance with a plan approved by the city engineer. B. Storm sewers and drainage facilities shall be designed according to the City of Huntsville specifications by a professional engineer registered in the State of Alabama in accordance with an acceptable method of design using good engineering practices as approved by the city engineer. The design of the stormwater drainage systems shall insure the adequate handling of stormwater runoff and the adequate control of erosion and sedimentation through the use of properly sized and positioned drainage structures and facilities. C. Lakes, ponds and similar facilities may be used to retain stormwater runoff to prevent or help drainage problems provided such facilities are in compliance with the stormwater management regulations promulgated by the city engineer and provided adequate provisions are made to control siltation and pollution. Lakes, ponds and similar areas may be accepted by the local government for maintenance as determined by the city engineer, if sufficient land is dedicated as a necessary part of the drainage control system. D. Drainage improvements and installations shall be constructed within dedicated rights-of-way and utility and drainage easements shown on the subdivision plat as approved by the city engineer. E. A licensed contractor shall be employed by the developer to install the drainage systems and facilities as shown in the approved subdivision. The work shall be accomplished according to the latest edition of the construction specifications and as directed by the city engineer. (2) Design considerations. A. The drainage plan shall consider the ultimate development of the drainage areas as determined by the current zoning on plats within the city or projected development patterns for plats outside the city limits. B. Large drainage concentrations requiring large facilities or open ditches shall be avoided within the subdivision boundary if at all possible. Where existing natural concentrations containing significant drainage areas cross the proposed subdivision, the developer's engineer shall utilize the natural condition and dedicate sufficient easements through the subdivision to contain natural drainage courses. C. All drainage structures shall be sized in every case to accommodate the specified design runoff from the entire upstream drainage area, whether the area lies inside or outside the subdivision. The city engineer shall evaluate the drainage facilities before approval to insure all drainage systems and facilities are sized correctly and comply with the construction specifications. D. Off-site drainage improvements to handle the increased runoff from the proposed subdivision into existing drainage facilities and off-site drainage easements may be required before approval by the city engineer. New drainage facilities shall be planned as much as practical to discharge into existing adequate systems downstream. The city engineer shall study the effect of each subdivision on existing downstream drainage facilities outside the boundaries of the planned subdivision. In the case where the planned subdivision or development will overload existing facilities and/or increase existing drainage problems, the city engineer may withhold approval of the drainage plan until provisions have been made to correct the drainage problems. (3) Flood prone areas. All local government rules and regulations pertaining to flood prone areas shall be observed when designing subdivisions. Particularly: A. Subdivisions lying in whole or in part within recognized flood hazard areas shall be subject to the provisions of the City of Huntsville Zoning Ordinance Floodway-Floodway Fringe Regulations or the applicable county flood damage prevention ordinance or other applicable regulations adopted by the city engineer. B. The boundaries of flood districts and hazard areas shall be as defined in the above-referenced ordinances. Any interpretation necessary shall be made by the city engineer. C. Lands within a floodway shall not be subdivided or developed except that certain minimal grading and construction may be allowed to provide for public utility service and/or roadways to cross said floodway. D. The city engineer shall prescribe on the plat minimum building floor elevations for structures located within flood districts where development is allowed. E. In other areas determined to have poor drainage that is subject to periodic or possible flooding, the city engineer may require the developer to fill to heights which will be above the elevation of the maximum design flood as determined by the engineer of record or the city engineer.

Ask a question about Huntsville law

Corpus searches the Huntsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.