Sec. 19-342. Testing and notice of defective private lateral.
a. The Director may periodically have special tests performed to confirm the integrity of the sanitary sewer system, including smoke testing, dyed water testing, air testing, hydraulic testing, closed circuit television inspection, and other testing and inspection techniques approved by the Director.
b. The Director or his designee may have designated and authorized city personnel or representative(s) enter private property to inspect or test a private lateral.
c. The city personnel, or representative, shall give the property owner not less than 24-hours written notice before city personnel, or representative, enter private property to conduct an inspection or test, unless:
1. city personnel or representative(s) are conducting an investigation of a complaint or responding to a customer request to test or inspect a private lateral; or
2. sewage is exposed on the property in a manner that creates a potential public health hazard.
d. The Director may identify defects in a private lateral that allow extraneous flow or debris to enter the private lateral or the discharge of sewage on the property, or a condition that may interfere with the proper operation of the private lateral.
e. A defect under this section may include, but is not limited to:
1. evidence of pipe or joint deterioration;
2. root intrusion into a pipe that separates a pipe joint or enlarges an existing crack;
3. a misaligned pipe segment, sag, or lack of positive gradient;
4. a broken cleanout, or lack of a necessary cleanout cap/stopper;
5. a downspout, drain, or other connection that allows storm water or other extraneous water to enter the sanitary sewer system; or
6. a flaw that allows the discharge of sewage on the property or the introduction of extraneous water into the sanitary sewer system.
f. Except as provided in Section 19-343b. (Repair required; standards), if the Director identifies a defective private lateral or a condition that interferes with the proper operation of the private lateral, the Director shall send the property owner written notice of the defect or condition, including a statement that the private lateral must be repaired, or the condition corrected, not later than the 120th day after the date of the notice.