Sec. 49-1310. - Return vents.

Island fixtures shall be installed as follows: (a) P-traps shall be placed as close to the fixture as possible. (b) A continuous vent shall be carried from above the flood level of the fixture and extend horizontally to a vent stack or stack vent. (See Figure 49-1310(b).) (c) Where the horizontal portion of the vent cannot be run under a bar or counter to a wall, the vent may be run downward to a level above the waste line, at or below the floor, and carried to and connected with a properly sized branch or main vent. (d) The vent shall be run in such a manner as to allow condensation to drain from the vent line. (See Figures 49-1310(d)-1, 49-1310(d)-2 and 49-1310(d)-3.)

(Ord. No. 40524, § 1, 10-20-15)