Section 9.8.5. - Minimum requirements for site improvements, utilities, dry floodproofing, and limitations.
All proposed new development shall be reviewed to determine that: A. Such proposals are consistent with the need to minimize flood damage and will be reasonably safe from flooding; B. All public utilities and facilities such as sewer, gas, electric, communications, and water systems are located and constructed to minimize or eliminate flood damage; and C. Adequate drainage is provided to reduce exposure to flood hazards; in Zones AH and AO, adequate drainage paths shall be provided to guide floodwaters around and away from proposed structures. D. All dry-floodproofing projects undertaken where permitted must have flood-resistant materials constructed and installed two additional feet above the minimum floodproofing elevation required by ASCE 24.