Sec. 23-429. - Technical considerations.
(a) If allowed, small cell facilities collocated on the same utility pole as a street light shall be on the same disconnect as the street light, where practicable. (b) Small cell facilities shall be grounded and otherwise comply fully with all applicable codes. (c) Whenever a conduit of small cell facilities crosses telephone or electric power wires, wires shall cross and be maintained in accordance with the National Electrical Code, the National Electrical Safety Code, and all applicable ordinances, codes and regulations of the city and all other applicable codes. (d) Small cell facilities and support structures shall comply with the applicable structural requirements with respect to wind loading. (e) The proposed facility or support structure shall comply with ANSI/TIA 222-G-2 structural safety requirements. (f) The proposed facility shall comply with FCC RF safety rules.
(Ord. No. 20-270, § 1, 4-9-2020)