For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 49-335 — Sanitary and storm sewer inspections

Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-335

Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/dc75b96b-1a5a-4399-9bf3-e3ad8fa9939b

Sec. 49-335. - Sanitary and storm sewer inspections.

Sanitary and storm sewer inspections shall be conducted as follows: (a) Boring or pipe bursting. (1) The inspector shall observe the unrestricted insertion of any pipe through holes bored underground. If the inspector believes excessive force has been applied to the pipe during insertion, an air test shall be performed on the portion of pipe installed through the hole. If the test fails, the inspector will require the pipe to be removed. (2) After the installation is complete, the pipe shall be flushed with water and videoed in the presence of the inspector. (This requirement does not apply to sewer pipe installations less than 75 feet long with a fall of one-half inch per foot or more.) (b) Open trench installation. (1) All sewer pipe sizes, laid in an open trench with less than one-eighth inch per foot fall, shall be flushed with water and videoed in the presence of an inspector. With cause, an inspector may require a pressure test on the piping.

(Ord. No. 40524, § 1, 10-20-15)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.