§ 11-58-7 — T4 MAIN STREET (T4MS) STANDARDS
Mesa City Code (Supp. No. 22: codified through Ordinance No. 5996, adopted March 9, 2026) · Mesa City Code § 11-58-7
Corpus is an independent public-information project, not the official City of Mesa website. Stable reference: corpuslaw.us/code/dd418140-6b69-4de9-abae-7a7008152710
11-58-7: - T4 MAIN STREET (T4MS) STANDARDS
A. Zone Intent and Description To integrate vibrant main-street commercial and retail environments into neighborhoods, providing access to daily amenities within walking distance, creating opportunities for transit stops and serving as a focal point for the neighborhood. [image omitted; see the official code] B. Building Types Allowed Building Types: | Main Street Mixed Use Mid-Rise | See Chapter 59: Building Type Standards for descriptions and regulations C. Building Placement [image omitted; see the official code] Build-to Lines (Distance from Property Line/ROW) Front | 0' max. | [image omitted; see the official code] Side Street | 0' max. | [image omitted; see the official code] Build-to Lines Defined by a Building Front, Lots <50' wide | 100% Front, Lots ≥50' wide | 75% min. 1, 2 Side Street | 50% min. 1, 2 Building Façade at Front BTL | 100% Setbacks (Distance from Property Line/ROW) Main Building Side | 0' min. 3 | [image omitted; see the official code] Rear | [image omitted; see the official code] Adjacent to T5N, T4N or T3N | 5' min. Adjacent to All Other Transect Zones | 0' min. Adjacent to Alley | 0' min. Accessory Dwelling Unit 4 | See Section 11-31-3: Accessory Dwelling Unit Miscellaneous A building form with a chamfered corner is permitted only if a corner entry is provided. D. Building Form [image omitted; see the official code] Height Main Building | 20' min.; 4 Stories max. 5, 6 | [image omitted; see the official code] Ground Floor Finish Level | 6" max. | [image omitted; see the official code] Ground Floor Ceiling | 14' min. clear | [image omitted; see the official code] Upper Floor (s) Ceiling | 9' min. | [image omitted; see the official code] Footprint Per Building Type Standards (see Chapter 59). Depth, Ground-Floor Space | [image omitted; see the official code] Commercial, Front | 50' min. Commercial, Side Street | 15' min Distance Between Entries Ground Floor | 50' max. Miscellaneous Upper floors shall have a primary entrance along the front. Loading docks, overhead doors, and other service entries may not be located on street-facing façades. E. Encroachments [image omitted; see the official code] Allowed Encroachments Front | 14' max. 7 | [image omitted; see the official code] Side Street | 14' max. 7 | [image omitted; see the official code] Rear | 5' max. 7 | [image omitted; see the official code] Miscellaneous See Chapter 60: Private Frontage Standards for additional encroachment standards specific to frontage types. F. Private Frontage Types Allowed Frontage Types | Forecourt Shopfront Gallery Arcade | See Chapter 60: Private Frontage Standards for private frontage type descriptions and regulations G. Parking [image omitted; see the official code] Required Spaces Residential Uses | 1/1,000 sf min. 8, 9 Retail and Service Uses | 2/1,000 sf min. 9, 10, 11 Location (Distance from Property Line/ROW) Front Setback | [image omitted; see the official code] Ground Floor | 50' min. Upper Floors | 30' min. Side Street Setback | 0' min. | [image omitted; see the official code] Side Setback | 0' min. | [image omitted; see the official code] Rear Setback | [image omitted; see the official code] Adjacent to T5N, T4N or T3N | 5' min. Adjacent to all other Transect Zones | 0' min. Adjacent to Alley | 0' min. Parking Access Drive Width | 12' min. 12 | [image omitted; see the official code] Miscellaneous All garages shall be screened from the front and the street by habitable space. Footnotes: 1. Entire BTL shall be defined by a building or a 24" to 42" high stucco or masonry wall, except for entryways, driveways, and walkways. 2. On corner lots, the BTL must be defined by a building for the first 30' from the corner. 3. No side setback required along the common property line between townhouse and/or duplex building types or for accessory structures when in conjunction with a townhouse or duplex building type. 4. Only allowed in conjunction with the Duplex Building Type. 5. Six (6) stories maximum permitted for buildings with more than 25% affordable or senior housing or for LEED Gold (or equivalent) certified buildings. 6. Within 20' of the rear property line, buildings may not be more than a half-story taller than the allowed height of adjacent buildings. 7. Encroachments only allowed within the ROW and public alleys within the Downtown Pedestrian Area. Encroachments must have a minimum 14' clear height and approval of an encroachment permit. 8. No parking spaces required for the first 2,000 sf of residential use, for affordable housing units, senior housing units, or Accessory Dwelling Units. 9. Shared parking may be used to meet parking requirements through a recorded parking agreement. 10. No parking spaces required for ground floor, non-residential uses less than 5,000 sf. 11. Off-site parking within 1,200' may be used to meet parking requirements for non-residential uses. 12. Maximum parking access drive width to be determined by Solid Waste and Fire access requirements.
(Ord. No. 5948, § 1, 7-1-25)
Ask a question about Mesa law
Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
