10.03.140 - Grease interceptor general requirements.
(a) All FSEs shall provide a GCD acceptable to the city under the requirements and standards established herein before discharging to any public sewer. Any FSE required to utilize a FOG GCD shall install, operate, and maintain an approved type and adequately sized grease interceptor necessary to maintain compliance with the objectives of this chapter. (b) Grease interceptor sizing and installation shall conform to the city's Plumbing Code. Interceptors shall be constructed in accordance with the design approved by the building official and shall have a minimum of two compartments with fittings designed for FOG retention. (c) The grease interceptor shall be installed at a location where it shall be at all times easily accessible for inspection, cleaning, and removal of accumulated FOG. (d) Access manholes, with a minimum diameter of twenty inches, shall be provided over each interceptor chamber and sanitary tee. The access manholes shall extend at least to finished grade and be designed and maintained to prevent non-wastewater inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, FOG removal, and wastewater sampling activities.
(Ord. No. 2363, § 4, 3-21-17)
Ask a question about Victorville law
Corpus searches the Victorville sections it holds and shows the ones that match, with their citations. Free, no sign-in.