15.16.400 - Fire Zones Nos. 1 and 2 - Special requirements.
It is hereby provided that in all those streets contained within the limits of the first and second fire districts of the city, as now or hereafter constituted, all side sewer lateral drains shall be installed with cast iron soil pipe of a minimum size of five inches; provided, that in any and all streets where the distance of the main sewer invert is a maximum four feet measured from the average elevation of the tops of the curbs only cast iron soil pipe shall be installed; provided, however, that storm drains of vitrified or concrete pipe of a minimum size of six inches may be installed at any place within the city.
(Prior code § 7331.)