Sec. 49-722. - Fixture requirement tables.
Table 49-722(1) Occupancy of 1,000 or more Where alcohol is served: WC/UR - Male | WC - Female | Lav - Male | Lav - Female | DF | Family RR 1 per 80 | 1 per 60 | 1 per 160 | 1 per 120 | See Note 3 | See section 49-708(d) Where no alcohol is served: WC/UR - Male | WC - Female | Lav - Male | Lav - Female | DF | Family RR 1 per 125 | 1 per 100 | 1 per 250 | 1 per 200 | See Note 3 | See section 49-708(d) Note 1: For places of worship with halls/auditoriums in the same building, the fixture requirements can be based on occupant load for the hall/auditorium if the occupant load is equal to or greater than the main worship hall/sanctuary. Note 2: The occupant load factor without fixed seating is seven square feet per person. The occupant load factor with fixed seating is 15 square feet per person. When individual seats are permanently anchored to the structure, the occupant load factor will be based on the count of seats. Where bench or pew seating is provided (i.e. stadiums and places of worship) 18 inches of linear bench or pew will count as one seat. Note 3: Provide six DF for the first 1,000 plus one for each additional 500 or fraction thereof. Note 4: Other fixtures will be required when food or drink is served, see section 49-701. Table 49-722(2) Occupancy of less than 1,000 Number | WC Male | UR Male | Lav Male | WC Female | Lav Female | DF | Family RR 1—25 | 1 | 0 | 1 | 1 | 1 | 0 | See section 49-708(d) 26—50 | 1 | 0 | 1 | 2 | 1 | 1 | See section 49-708(d) 51—75 | 1 | 1 | 1 | 3 | 2 | 1 | See section 49-708(d) 76—100 | 1 | 1 | 1 | 4 | 2 | 1 | See section 49-708(d) 101—200 | 2 | 1 | 2 | 5 | 3 | 2 | See section 49-708(d) 201—300 | 2 | 2 | 2 | 6 | 3 | 3 | See section 49-708(d) Fixture requirements for occupant loads above 300: (a) Males: Add one water closet or one urinal for each additional 200 or fraction thereof. Add one lavatory for each additional 400 or fraction thereof. (b) Females: Add one water closet for each additional 150 or fraction thereof. Add one lavatory for each additional 300 or fraction thereof. (c) Provide one additional DF for each 150 persons or fraction thereof. Note 1: The occupant load factor without fixed seating is seven square feet per person. The occupant load factor with fixed seating is 15 square feet per person. When individual seats are permanently anchored to the structure, the occupant load factor will be based on the count of seats. Where bench or pew seating is provided (i.e. stadiums and places of worship) 18 inches of linear bench or pew will count as one seat. Note 2: Other fixtures will be required when food or drink is served, see section 49-701. Note 3: For places of worship with hall/auditoriums in the same building, the fixture requirements may be based on occupant load for the hall/auditorium if the occupant load is equal to or greater than the main worship hall/sanctuary. Table 49-722(3) Number | WC Male | UR Male | Lav Male | WC Female | Lav Female | DF 1—25 | 1 | 0 | 1 | 1 | 1 | 0 26—50 | 1 | 0 | 1 | 2 | 1 | 1 51—75 | 1 | 1 | 1 | 3 | 2 | 1 76—100 | 1 | 1 | 1 | 4 | 2 | 1 101—200 | 2 | 1 | 2 | 5 | 3 | 2 201—300 | 2 | 2 | 2 | 6 | 3 | 3 Fixture requirements for occupant loads above 300: (a) Males: Add one water closet or one urinal for each additional 200 or fraction thereof. Add one lavatory for each additional 400 or fraction thereof. (b) Females: Add one water closet for each additional 100 or fraction thereof. Add one lavatory for each additional 200 or fraction thereof. (c) Provide one additional DF for each 150 persons or fraction thereof. Note 1: Drinking fountains will not be required if water is provided to the customer of the business without charge. Note 2: Any restaurant that serves alcoholic beverages or liquor for consumption on premises as part of the meal served shall be considered as a restaurant that does not serve alcoholic beverages. Note 3: Occupant load shall be based on 15 square feet per person after deducting areas such as stairwells, restrooms, entries, elevators, dance floors, kitchen, bar areas, and utility rooms. Employees are factored in the 15 square feet occupant load. Note 4: Other fixtures will be required when food or drink is served, see section 49-701. Note 5: Restaurants with inside and outside seating will not be required to have additional restroom facilities for the outside seating if the outside seating does not exceed 25 percent of the interior seating. However, if the outside seating exceeds 25 percent of the inside seating, those seats in excess of the 25 percent shall be added to the inside seating for the purpose of establishing total occupancy and restroom facility requirements for the business. Note 6: Establishments with only outside seating shall meet all requirements for restroom facilities. Note 7: Restaurants are required to have restrooms located in the space occupied. Food courts shall have restrooms located adjacent to the main dining area. Note 8: In buildings constructed of multiple floors, the fixture count shall be based on the number of occupants of each floor and accessibility to the fixtures shall be on each floor including mezzanines with an occupant load of more than ten. Note 9: Drinking fountains will not be required if water is provided to the customer of the business without charge. Table 49-722(4) Number | WC Male | UR Male | Lav Male | WC Female | Lav Female | DF 1—25 | 1 | 0 | 1 | 1 | 1 | 0 26—50 | 1 | 1 | 1 | 2 | 1 | 1 51—75 | 1 | 1 | 1 | 3 | 2 | 1 76—100 | 1 | 1 | 1 | 4 | 2 | 1 101—150 | 2 | 1 | 2 | 5 | 3 | 2 151—200 | 2 | 1 | 2 | 6 | 3 | 2 201—250 | 2 | 2 | 2 | 7 | 4 | 2 251—300 | 2 | 2 | 3 | 8 | 4 | 3 Fixture requirements for occupant loads above 300: (a) Males: add one water closet or one urinal for each additional 100 or fraction thereof. Add one lavatory for each additional 200 or fraction thereof. (b) Females: add one water closet for each additional 60 or fraction thereof. Add one lavatory for each additional 120 or fraction thereof. Note 1: Other fixtures will be required when food or drink is served; see section 49-701. Note 2: Occupant load shall be based on 15 square feet per person after deducting areas such as stairwells, restrooms, entries, elevators, dance floors, kitchen, bar areas, and utility rooms. In buildings constructed of multiple floors, the fixture count shall be based on the number of occupants of each floor and accessibility to the fixtures shall be on each floor including mezzanines with an occupant load of more than ten. Note 3: Provide one additional DF for each 100 persons or fraction thereof. Drinking fountains will not be required if water is provided to the customer of the business without charge. Note 4: Establishments serving liquor with inside and outside seating will not be required to have additional restroom facilities for the outside seating if the outside seating does not exceed 25 percent of the interior seating. However, if the outside seating exceeds 25 percent of the inside seating, those seats in excess of the 25 percent shall be added to the inside seating for the purpose of establishing total occupancy and restroom facility requirements for the business. Note 5: The requirements for restroom facilities in establishments with only outside seating shall be based on the total number of outside seats. Note 6: Establishments serving liquor are required to have restrooms located in the space occupied by the establishment. Use the Table 49-722(5A) below to determine occupant load factor. Table 49-722(5A) Business Category | Use Type | Occupant Load Factor SF/Person | Multiply By | Combined Factor A1 | Industrial/Manufacturing | 200 | 0.30 | 667 A2 | Warehouse | 500 | 0.30 | 1,667 A3 | Professional Offices | 160 | 1.00 | 160 A4 | Telemarketing/Data Entry | 100 | 1.00 | 100 A5 | Exercise Rooms | 50 | 0.50 | 100 A6 | Hospital Employee Areas | 15 | 1.00 | 15 A7 | Clinic/Medical Offices | 240 | 1.00 | 240 A8 | Motor Vehicle Repair | 300 | 1.00 | 300 Use the Table 49-722(5B) below to determine fixture requirements. Table 49-722(5B) Number | WC - Male | UR - Male | Lav Male | WC Female | Lav - Female 1—5 | 1 | 0 | 1 | 1 | 1 6—10 | 1 | 0 | 1 | 2 | 1 11—25 | 1 | 1 | 1 | 3 | 2 26—50 | 1 | 1 | 1 | 4 | 2 51—75 | 2 | 2 | 2 | 5 | 3 76—100 | 3 | 2 | 3 | 6 | 3 101—150 | 4 | 3 | 4 | 7 | 4 151—200 | 5 | 3 | 4 | 8 | 4 201—250 | 6 | 4 | 5 | 9 | 5 251—300 | 7 | 4 | 6 | 10 | 5 Fixture requirement for occupant loads above 300: (a) Males: Add one water closet or one urinal for each additional 50 or fraction thereof. Add one lavatory for each additional 100 or fraction thereof. (b) Females: Add one water closet for each additional 50 or fraction thereof. Add one lavatory for each additional 100 or fraction thereof. (c) See Table 49-722(5C) below for drinking fountains requirements. Occupancies of 25 or less shall not be required to provide a drinking fountain. Table 49-722(5C) Type of Business | Drinking Fountain A1, A3, A4, A5, A6, A7, A8 | 1 per 100 A2 | 1 per 1,000 Note 1: In buildings constructed of multiple floors, the fixture count shall be based on the number of occupants of each floor and accessibility to the fixtures shall be on each floor including mezzanines with an occupant load of more than ten. A centrally located common restroom facility is allowed to meet the plumbing fixture requirements of multi-tenant business, dental and medical offices. Note 2: Office common areas are not used to determine occupant load. The common areas include break rooms, waiting rooms, elevator lobbies, atriums, restrooms, and mechanical equipment rooms. Conference or meeting rooms may be considered common areas if they are used only by the resident staff. Table 49-722(6) Number | WC Male | UR Male | Lav Male | WC Female | Lav Female | DF | Family RR 1—25 | 1 | 0 | 1 | 1 | 1 | 0 | See Sec. 49-708(d) 26—50 | 1 | 0 | 1 | 1 | 1 | 1 | See Sec. 49-708(d) 51—100 | 1 | 1 | 1 | 2 | 1 | 1 | See Sec. 49-708(d) 101—200 | 2 | 1 | 2 | 3 | 2 | 2 | See Sec. 49-708(d) 201—400 | 2 | 2 | 2 | 4 | 2 | 3 | See Sec. 49-708(d) 401—600 | 2 | 3 | 3 | 5 | 3 | 4 | See Sec. 49-708(d) Fixture requirements for occupant loads above 600: (a) Males: Add one water closet or one urinal for each additional 200 or fraction thereof. Add one lavatory for each additional 400 or fraction thereof. (b) Females: Add one water closet for each additional 200 or fraction thereof. Add one lavatory for each additional 400 or fraction thereof. (c) Provide one additional DF for each 300 persons or fraction thereof. Note 1: The occupancy load factor for retail is 30 square feet per person multiplied by 0.40. The occupancy load for malls is 60 square feet per person. Note 2: In stores of 2,000 gross square feet or less (located in covered shopping centers or malls): the requirements of this section may be satisfied by a centrally located facility accessible to several stores, provided that the centrally located facility is adequately sized and not more than 200 feet from the entry of any store. Note 3: In buildings constructed of multiple floors, the fixture count shall be based on the number of occupants of each floor and accessibility to the fixtures shall be on each floor including mezzanines with an occupant load of more than ten. Table 49-722(7) Number | WC Male | UR Male | Lav Male | Showers Male | WC Female | Lav Female | Showers Female | DF 1—25 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 26—50 | 1 | 1 | 1 | 2 | 2 | 1 | 2 | 1 51—75 | 2 | 1 | 1 | 3 | 3 | 2 | 3 | 1 76—100 | 2 | 1 | 2 | 4 | 4 | 2 | 4 | 1 101—200 | 3 | 1 | 2 | 5 | 5 | 3 | 5 | 2 201—300 | 3 | 2 | 3 | 6 | 6 | 3 | 6 | 3 Fixture requirements for occupant loads above 300: (a) Males: Add one water closet or one urinal for each additional 150 or fraction thereof. Add one lavatory for each additional 300 males or fraction thereof. (b) Females: Add one water closet for each additional 150 or fraction thereof. Add one lavatory for each additional 300 females or fraction thereof. Provide one additional DF for each 300 persons or fraction thereof. Note 1: Occupant load for outside swimming pools will be based on 15 square feet per person of pool area. Note 2: Indoor pools in hotels and motels shall have a minimum of one water closet and one lavatory for males and one water closet and one lavatory for females located adjacent to the pool. Note 3: See section 49-708(d) for family use restroom requirements. Note 4: In buildings constructed of multiple floors, the fixture count shall be based on the number of occupants of each floor and accessibility to the fixtures shall be on each floor including mezzanines with an occupant load of more than ten. Table 49-722(8A) Per Floor | WC | Lav | DF | MS Preschool/nursery | 1 per 15 | 1 per 15 | 1 per 30 | 1 Elementary | 1 per 25 | 1 per 50 | 1 per 75 | 1 Secondary | 1 per 30 | 1 per 60 | 1 per 75 | 1 College/University | 1 per 35 | 1 per 70 | 1 per 75 | 1 Adult daycare | 1 per 35 | 1 per 70 | 1 per 75 | 1 Note 1: Under Table 49-722(8A) the occupant load factor is 35 sq. ft. per students. (This also applies to preschools, nurseries and adult daycare.) Note 2: Preschool/nursery may be required to meet other standards set by the health department. Children two years old and under are not counted in determining fixture requirements. To determine the staff requirement for daycares and nurseries use Table 49-722(8B) below: Table 49-722(8B) Age of Children | Number of Staff | Number of Children 6 weeks to 18 months | 1 | 4 18 months to 3 years | 1 | 6 3 years | 1 | 10 4 and 5 years | 1 | 12 Kindergarten and up | 1 | 15 Note 3: For children six years of age and under, a unisex restroom may be used. For children over seven years of age, separate accommodations shall be provided. Note 4: Facilities for school staff shall be separate and in addition to those for the students using Table 49-722(5B). Note 5: Occupant load for collaborative learning classrooms and common areas will be based on Table 49-722(8C) below. Table 722(8C) Use/Function | O. L. Factor | Multiplier Large Classroom (1800 sq. ft.) * | 35 | 1 Medium Classroom (900 sq. ft.) * | 30 | 1 Small Classroom (600 sq. ft.) * | 40 | 1 Learning Commons * | 50 | 1 *Fixture count shall be based on the largest occupant load between the collaborative classroom population and the designated collaborative learning common areas. Learning common areas shall include libraries, cafeterias, locker rooms, hallways over eight feet wide, and all other such meeting and study areas where students and faculty may congregate before and after classes. Inclusion of multi-use auditoriums in the learning commons' areas shall be reviewed on a case by case basis. Note 6: Restrooms for the general school population may be used to accommodate the requirement for auditoriums, gyms, athletic fields and swimming pools and for public events, provided there is easy access to the restrooms for those attending the events. Easy access shall mean the travel distance from any point on the property to the restroom(s) shall not exceed 200 feet and accessible. Note 7: While Note 6 allows for the restrooms that serve the general school population to accommodate the requirement for auditoriums, gyms, athletic fields and swimming pools, the requirements for a family use restroom for assembly in section 49-708 and 49-720 will need to be met. Table 49-722(9) Number | WC | Lav | Showers 1—20 | 2 | 1 | 2 21—40 | 3 | 2 | 3 41—60 | 4 | 2 | 4 61—80 | 5 | 3 | 5 81—100 | 6 | 3 | 6 Fixture requirements for occupant loads above 100: (a) One DF for each 100 or fraction thereof or one per floor. (b) One MS per floor. (c) One clothes washer for each ten people or fraction thereof. (d) Add one WC for each additional 20 or fraction thereof. (e) Add one lavatory for each additional 40 or fraction thereof. (f) Add one shower for each additional 20 or fraction thereof. Note 1: In buildings constructed of multiple floors the fixture count shall be based on the number of occupants of each floor and, accessibility to the fixtures shall be on each floor. Note 2: Rooming houses: (a) Rooming houses with shared bathroom and restroom facilities must conform to the following minimum number of fixtures: one water closet; one lavatory; and one bathtub or shower and one clothes washer for each four rooming units, or portion thereof. (b) Restrooms and bathrooms shall provide privacy and shall not constitute the only passageway to a hall or other space or to the exterior. A door and interior locking device shall be provided for all common or shared bathrooms and restrooms in a multiple dwelling. Restrooms and bathrooms shall be accessible on each floor from a common hall or passageway. Table 49-722(10) WC | Lav | SH | MS | DF Individual rooms | 1 | 1 | 1 | 1 per floor | 0 Wards (one per four patients) | 1 | 1 | 1 | 1 per floor | 1 Bed pan washer shall be as required by Nebraska Health and Human Services Title 175 NAC 9 Hospital employee areas, hospital waiting rooms, surgical waiting room Number | WC Male | UR Male | Lav Male | WC Female | Lav Female | DF 1—25 | 1 | 0 | 1 | 1 | 1 | 0 26—50 | 1 | 1 | 1 | 2 | 1 | 0 51—75 | 1 | 1 | 1 | 3 | 2 | 0 76—100 | 1 | 2 | 2 | 4 | 2 | 1 101—150 | 2 | 2 | 2 | 5 | 3 | 1 151—200 | 3 | 2 | 3 | 6 | 3 | 1 201—250 | 4 | 3 | 4 | 7 | 4 | 2 251—300 | 5 | 3 | 4 | 8 | 4 | 2 301—350 | 6 | 4 | 5 | 9 | 5 | 2 351—400 | 7 | 4 | 6 | 10 | 5 | 3 Occupant Load Factor SF/Person | Multiply By Administration offices | 160 | 1.00 Surgical waiting room | 15 | 1.00 Public waiting room (lobby) | 200 | 1.00 Fixtures required for occupant loads above 400 the following shall apply: (a) For males add one water closet or one urinal for each additional 100 or fraction thereof. Add one lavatory for each additional 200 or fraction thereof. (b) For females add one water closet for each additional 100 or fraction thereof. Add one lavatory for each additional 200 or fraction thereof. (c) Provide one additional DF for each 300 persons or fraction thereof. Note 1: In buildings constructed of multiple floors, the fixture count shall be based on the number of occupants of each floor and accessibility to the fixtures shall be on each floor including mezzanines with an occupant load of more than ten. Note 2: Separate restrooms shall be provided for employee's areas (See Table 5). Note 3: Bed pan washer shall be as required by Nebraska Health and Human Services Title 175 NAC 9. _____
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 24, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.