11-30-5: - LIGHTING AND ILLUMINATION

The objective of this Section is to promote well designed lighting that can enhance the design of a building or site by highlighting interesting architectural details, calling attention to interesting textures and colors, and focusing attention to primary site features. Such lighting should be controlled to minimize adverse impacts to abutting residential uses. A. Applicability: The requirements of this Section shall apply to all projects except Single Residence Dwellings and Middle Housing. B. Parking Lot Illumination: 1. Location. Light poles shall be located only within the parking area or, where permitted, the outdoor storage area, and shall not encroach into required perimeter landscape areas. 2. Light Pole Heights. a. Maximum light pole height shall be 15 feet when within 50 feet of the perimeter of the development and adjacent to a residential use or zoning district. b. When adjacent to any other use, the maximum height shall be 20 feet within 50 feet of the perimeter. c. The maximum height shall be 25 feet everywhere else on the site. 3. Light Shields. House side shields shall be provided on all light standards adjacent to residential development. 4. Building Mounted Lights. Building mounted lights shall maintain the same heights as specified in subsection C., below. 5. Lighting and Electric Code. For additional standards refer to the Mesa Lighting and Electrical Code; Title 4, Chapter 4 of the Mesa City Code. C. Maximum Height of Lighting Fixtures. 1. Lighting fixtures, including freestanding light poles as well as building-mounted lights, shall not exceed the maximum heights specified in Table 11-30-5 below. Table 11-30-5: Maximum Height of Lighting Fixtures District | Maximum Height (ft.) - Detached | Maximum Height (ft.) - Attached Residential Districts | 15 | Not to exceed the peak elevation of the immediately adjacent sloped roof, parapet, or building elevation to which the fixture is attached DC and DB Districts | 20 All other Non-Residential Districts | Within 50 feet of any street frontage: 20 ft. Within 50 feet of a Residential District: 15 ft. Any other location: 25 ft. 2. Exceptions to the maximum height of lighting fixtures may be approved by the Zoning Administrator, after a review of a photometric study. Such exceptions may include requirements for use light control devices, such as fully shielded or full cut-off fixtures, to reduce glare and light-spillage onto abutting properties. D. Exposed Exterior Building Illumination. Exposed neon, argon, led or krypton tubing; exposed incandescent lighting; or other exposed artificial lighting used to outline or accent a structure or portion thereof is permitted subject to the following: 1. Placement. a. Exposed lighting shall be mounted within 12 inches of a permanent architectural element (e.g., parapet or cornice line, canopy/awning edge, pilaster/column, entry surround) and shall not be freestanding on blank wall areas. b. Exposed lighting shall not be placed above the roof or parapet, or on rooftop equipment or on top of fences. 2. Quantity. A maximum of two (2) horizontal runs (e.g. along parapet or canopy edges) and one (1) vertical run (e.g. along corners or entry surrounds) is permitted on each façade. 3. Color. One (1) static color or hue is permitted per building. 4. Advertising/Signage Prohibited. Tubing shall not form letters, numbers, symbols, logos, product shapes, or trademark color patterns, and shall not be attached to or integrated with any sign face. 5. Motion and Effects Prohibited. Flashing, blinking, pulsing, chasing, and strobing effects are prohibited. 6. Full Functionality Required for Use. If any component or segment of the lighting system is nonfunctional, all exposed lighting on the building shall remain off until the entire lighting system is fully repaired.

(Res. No. 12269, §§ 10, 11, 9-23-24; Ord. No. 5883, § 3, 10-7-24; Ord. No. 5996, § 4, 3-9-26)

Ask a question about Mesa law

Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.