Sec. 14-301. - Swimming pool and spa code.
The International Swimming Pool and Spa Code, 2021 Edition, as published by the International Code Council, is incorporated by reference and adopted as the Swimming Pool and Spa Code for the City of Corpus Christi with the following local amendments (Additions to the International Swimming Pool and Spa Code are shown as underlined text. Deletions to the International Swimming Pool and Spa Code are shown as strikethroughs): 101.1 Title. These regulations shall be known as the Swimming Pool and Spa Code of the City of Corpus Christi, hereinafter referred to as "this code." 103.1 Creation of agency. The City of Corpus Christi Development Services Department is hereby created named and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. 106.1 Construction documents. Construction documents, engineering calculations, diagrams and other such data shall be submitted in two or more sets with each application for a permit. The code official shall require construction documents, computations and specifications to be prepared and designed by a registered design professional where required by state law. Construction documents shall be drawn to scale and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that the work conforms to the provisions of this code. A licensed engineer's design is required for class A and B pools. (25 Tex. Admin. Code §265.183(b)). 112.1 Membership of board. The board of appeals shal consist of five members appointed by the chief appointing authority as follows: one for 5 years, one for 4 years, one for 3 years, one for 2 years and one for 1 year. Thereafter, each new member shall serve for 5 years or until a successor has been appointed. Refer to Section 14-206 Technical Construction Boards for details on the establishment, duties and powers, and appeals process of the construction trade advisory & appeals board. 113.4 Violation penalties. Any person who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair a pool or spa in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be guilty of a [SPECIFY OFFENSE], punishable by a fine of not more than [AMOUNT] dollars or by imprisonment not exceeding [NUMBER OF DAYS], or both such fine and imprisonment. Each day that a violation continues after due notice has been served shall be deemed a separate offense. Refer to Section 14-207 Violations and Penalties. 305.2.1 Barrier height and clearances. Barrier heights and clearances shall be in accordance with all the following: 1. The top of the barrier shall be not less than 48 inches (1,219 mm) above grade where measured on the side of the barrier that faces away from the pool or spa. Such height shall exist around the entire perimeter of the barrier and for a distance of 3 feet (914 mm) measured horizontally from the outside of the required barrier. Fence height to be 6 feet for Class A and B pools; 4 feet for Class C (Semi-public). (25 Tex. Admin. Code §265.203 (c)) 2. The vertical clearance between grade and the bottom of the barrier shall not exceed 2 inches (51 mm) for grade surfaces that are not solid, such as grass or gravel, where measured on the side of the barrier that faces away from the pool or spa. 3. The vertical clearance between a surface below the barrier to a solid surface, such as concrete, and the bottom of the required barrier shall not exceed 4 inches (102 mm) where measured on the side of the required barrier that faces away from the pool or spa. 4. Where the top of the pool or spa structure is above grade, the barrier shall be installed on grade or shall be mounted on top of the pool or spa structure. Where the barrier is mounted on the top of the pool or spa, the vertical clearance between the top of the pool or spa and the bottom of the barrier shall not exceed 4 inches (102 mm). 305.2.7 Chain link dimensions. The maximum opening formed by a chain link fence shall be not more than 1¾ inches (44 mm). Where the fence is provided with slats fastened at the top and bottom that reduce the openings, such openings shall be not greater than 1¾ inches (44 mm).No chain link fences are allowed for Class A and B pools. (Tex. Health & Safety Code § 757.003 (f)). Where chain link fence is used in a Class C pool, an approved barrier is to be provided; to make the fence difficult to climb (25 Tex. Admin. Code §265.203). 305.2.9 Clear zone. Where equipment, including pool equipment such as pumps, filters and heaters, is on the same lot as a pool or spa and such equipment is located outside of the barrier protecting the pool or spa, such equipment shall be located not less than 36 inches (914 mm) from the outside of the barrier. Adjacent structures/trees shall be at least 10 feet away from pool to prevent jumping or diving into pool. 305.3.3 Latch release. For doors and gates in barriers, the door and gate latch release mechanisms shall be in accordance with the following: 1. Where door and gate latch release mechanisms are accessed from the outside of the barrier and are not of the self-locking type, such mechanism shall be located above the finished floor or ground surface in accordance with the following: 1.1. At public pools and spas, not less than 52 inches (1,219 mm) and not greater than 54 inches (1,372 mm). 60 inches. (Tex. Health & Safety Code § 757.004(b).) 1.2. At residential pools and spas, not less 54 inches (1,372 mm). 2. Where door and gate latch release mechanisms are of the self-locking type such as where the lock is operated by means of a key, an electronic opener or the entry of a combination into an integral combination lock, the lock operation control and the latch release mechanism shall be located above the finished floor or ground surface in accordance with the following: 2.1. At public pools and spas, not less than 34 42 inches and not greater than 48 inches (1,219 mm). Gate cannot be opened from either side except by card, key, or combination of both unless pool is continuously supervised by staff for class A and B pools and residential youth camp pools. (Tex. Health & Safety Code 757.004(c); 25 Tex. Admin. Code § 265.203 (c)). 2.2. At residential pools and spas, not greater than 54 inches (1,372 mm). 3. At private pools, where the only latch release mechanism of a self-latching device for a gate is located on the pool and spa side of the barrier, the release mechanism shall be located at a point that is at least 3 inches (76 mm) below the top of the gate. 401.7 Drinking Fountains. Drinking fountains are required for all public swimming pools (25 Tex. Admin. Code § 265.198(e)).
(Ord. No. 031899, § 2, 10-15-2019; Ord. No. 032968, § 9, 1-31-2023)
Ask a question about Corpus Christi law
Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.