Sec. 7-195. - Cleaning maintenance requirements for grease interceptors and traps.
(a) Partial pump of interceptor contents or on-site pump and treatment of interceptor contents will not be allowed due to the reintroduction of FOG to the interceptor and pursuant to the city of Greenville Sewer Use Ordinance and as referenced in the 40 Code of Federal Regulations (CFR) § 403.5 (b)(8), which states "Prohibited discharges. No persons shall discharge or cause or allow to be discharged or deposited into the city's wastewater system any wastewater that contains the following: Any trucked or hauled pollutants, except at discharge points designed, permitted, and approved by the city." (b) Grease interceptors must be pumped-in-full (total pump of all contents) when the total accumulations of surface FOG (including floating solids) and settled solids reaches twenty-five percent (25%) of the grease interceptor's overall liquid depth. This criterion is referred to as the "25 percent rule." At no time, shall the cleaning frequency exceed ninety (90) days unless approved by the city. Approval will be granted on a case by case basis with submittal by the FSE documenting proof of proposed frequency. Some existing FSEs in Class 2 through 5 will need to consider a more frequent pumping schedule. (c) The grease interceptor will be inspected during cleaning and maintenance and the condition noted by the grease waste hauler's company or individual conducting the maintenance. Influent and/or effluent-T's that are loose, defective, or unattached must be repaired or replaced immediately. Any other damaged or defective parts of the grease interceptor observed during the inspection must also be repaired or replaced immediately. Any repairs should be documented and kept on file at the FSE. (d) Grease interceptors must have access manholes over the influent-T and effluent-T for inspection and ease of cleaning/maintenance. Access manholes will be provided for all separate compartments of interceptors for complete cleaning (i.e. interceptor with two (2) main baffles or three (3) compartments will have access manholes at each compartment). (e) Grease interceptor waste must be hauled offsite and disposed of at a State- or POTW- approved disposal location. (f) Grease interceptors must be "certified" annually by a city licensed plumber. An Annual Grease Interceptor Certification and Construction Inspection Form (Attachment B) must be completed and submitted to the city annually. (g) FSEs which operate infrequently or only for special events may request a modification to the maintenance schedule specified above. The director may authorize a maintenance frequency related to the operation of the FSE. The user shall submit a request for a modified maintenance schedule which includes all details of operation for the director to review. (h) The user shall be responsible for retaining records of the maintenance of grease interceptors and traps including manifests, permits, permit applications, sampling data, correspondence and any other documentation that may be requested by the city. These records shall include the dates of service, volume of waste removed, waste hauler and disposal site of waste. These records shall be kept on-site at the location of the grease interceptor or trap for a period of three (3) years and are subject to review without prior notification.
(Ord. No. 18-001, § I, 1-25-18)
Ask a question about Greenville law
Corpus searches the Greenville sections it holds and shows the ones that match, with their citations. Free, no sign-in.