Sec. 37-43. - New structures—Lowest floor elevations.

(a) In local floodplains, the lowest floor of a new structure shall be at or above the RFE. (b) In areas outside of floodplains, a new structure shall be constructed as follows: (1) If the structure is in Flood Hazard Zone D or X, the lowest floor shall be at least fourteen (14) inches above the highest adjacent grade; or (2) The structure shall be constructed in conformance with a plan prepared and certified by an engineer showing that elevations are sufficiently high to provide protection from a base flood. (c) In local floodplains, a depressed floor area shall not be considered as the lowest floor if: (1) There is no door opening directly to the outside which could admit flood water into the depressed floor area; and (2) The depressed area walls and floor are sealed to prevent the infiltration of water into the depressed area.

(Ord. No. 4246, § 1(Res. No. 10402, § 1, Exh. A), 7-6-16)