295-1133. Floodproofing.

1. No permit or floodplain variance shall be issued for a non-residential structure designed to be watertight below the regional flood elevation until the applicant submits: a. A plan certified by a registered professional engineer or architect that the floodproofing measures taken will protect the structure or development to the flood protection elevation. b. A federal emergency management agency floodproofing certificate. 1.5. Floodproofing shall not be an alternative to the development standards of s. 295-1119, s. 295-1121, s. 295-1127, s. 295-1128 or s. 295-1133. 2. For a structure designed to allow the entry of floodwaters, no permit or floodplain variance shall be issued until the applicant submits a plan that meets either of the following: a. The plan is certified by a registered professional engineer or architect. b. The plan meets or exceeds the following standards: b-1. A minimum of 2 openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding have been provided. b-2. The bottom of all openings shall be no higher than one foot above grade. b-3. Openings may be equipped with screens, louvers, valves or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters. 3. Floodproofing measures shall be designed, as appropriate, to: a. Withstand flood pressures, depths, velocities, uplift and impact forces, and other regional flood factors. b. Protect structures to the flood protection elevation. c. Anchor structures to foundations to resist flotation and lateral movement. d. Minimize or eliminate infiltration of floodwaters. e. Minimize or eliminate discharges into floodwaters. f. Placement of essential utilities to or above the flood protection elevation. g. If any part of the foundation below the flood protection elevation is enclosed, the following standards shall apply: g-1. The enclosed area shall be designed by a registered architect or engineer to allow for the efficient entry and exit of flood waters without human intervention. A minimum of 2 openings shall be provided with a minimum net area of at least one square inch for every one square foot of the enclosed area. The lowest part of the opening shall not be more than 12 inches above the adjacent grade. g-2. The parts of the foundation located below the flood protection elevation shall be constructed of flood-resistant materials. g-3. Mechanical and utility equipment shall be elevated to or above the flood protection elevation. g-4. The use shall be limited to parking, building access or limited storage.

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.