§ 18-85 — Electrical facilities
Code of Ordinances, City of Burlington, Vermont (Current through Ord. 8-3-26, passed August 3, 2026) · Burlington Code of Ordinances § 18-85
Corpus is an independent public-information project, not the official City of Burlington website. Stable reference: corpuslaw.us/code/e1391625-7a1a-49a6-8ee2-3131a9fc1127
18-85 Electrical facilities.
(a) Where there is electric service available to a structure, every habitable room of a dwelling unit and every rooming unit shall contain at least two (2) separate and remote outlets, one of which may be a ceiling-or wall-type electric light fixture. In a kitchen, three (3) separate and remote wall-type electric convenience outlets or two (2) such convenience outlets and one ceiling-or wall-type electric light fixture shall be provided. Every public hall, laundry room, bathroom or furnace room shall contain at least one electric light fixture. In addition to the electric light fixture in every bathroom and laundry room, there shall be provided at least one electric outlet. (b) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner in accordance with applicable laws. Wiring of the type known as knob and tube which uses porcelain insulators and single cloth-covered conductors will be permitted when a licensed electrician provides written assurance that the wiring is not overloaded and that the condition of the conductors and the insulators is sound and substantially without defect or hazard. (c) Buildings containing two (2) or more dwelling units shall have any common lighting and common building facilities connected to either an individual circuit or circuits fed from an individual house meter or from the meter serving the owner/occupant of the property. When and if an owner/occupant terminates his occupancy, the general building lighting and common facilities shall be connected to a common house meter. The owner shall be liable for the costs of providing energy to common areas. (d) Where the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the defects shall be corrected to eliminate the hazard.
(Ord. of 8-4-86)
Ask a question about Burlington law
Corpus searches the Burlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.