§ 9-25 — Amendments to the 2024 International Swimming Pool and Spa Code
Code of the City of Glendale, Arizona (Supp. No. 115: codified through Ordinance No. O26-19, adopted April 14, 2026) · Glendale City Code § 9-25
Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/e2088787-c167-4615-8244-4c49d559a6ed
Sec. 9-25. - Amendments to the 2024 International Swimming Pool and Spa Code.
The International Swimming Pool and Spa Code, 2024 Edition, is amended in the following respects: Section 101.1 is amended to read as follows: 101.1 Title. These regulations shall be known as the Swimming Pool and Spa Code of Glendale, Arizona, hereinafter referred to as "this code." Chapter 1, Scope and Administration is amended by the deletion of Sections 102 through 114. For administration of this code, see the 2024 International Building Code and related amendments. ISPSC Section 202, Definitions: RESIDENTIAL SWIMMING POOL (Residential Pool). Revise this definition as follows: A pool intended for use that is accessory to a residential dwelling and available only to the household and its guest including any structure intended for swimming, dipping or immersion purposes with a minimum water depth of 18 inches (457.2 mm). This includes in-ground, above-ground and on-ground swimming pools, hot tubs, spas and fixed-in-place wading pools. All other pools shall be considered public pools for purposes of this code. ISPSC Section 305.1, Barrier requirements, General. Add the following text: It is the responsibility of the property owner and any other person in responsible charge of a swimming pool to ensure that the required swimming pool barrier, including all gates, doors, locks, latches, and other portions of the barrier are maintained safe and in good working order at all times. No person shall alter or remove any portion of a swimming pool barrier except to repair, reconstruct, or replace the barrier in compliance with provisions of this section. All barriers shall be installed, inspected and approved prior to plastering or filling with water. ISPSC Section 305.2.1, Barrier height and clearances. Revise item #1 to read as follows: 1. The top of the barrier shall be not less than 60 inches (1524 mm) above grade where measured in the side of the barrier that faces away from the pool or spa. Such height shall exist around the entire perimeter of the barrier and for a distance of 3 feet (914 mm) measured horizontally from the outside of the required barrier. A dwelling or accessory building may be used as part of such barrier. ISPSC Section 305.2.1, Barrier height and clearances. Add the following item: 5. The barrier shall be at least 20 inches from the water's edge. ISPSC Section 305.2.5, Mesh fence as a barrier. Delete the text and replace with the following: Mesh fences, other than chain link fences in accordance with Section 305.2.8, shall be installed in accordance with the manufacturer's instructions and shall comply with ASTM F2286 and with all of the following: 1. The bottom of the mesh fence shall be not more than 1 inch above the deck or installed surface or grade. 2. The maximum vertical clearance from the bottom of the mesh fence and the solid surface shall not permit the fence to be lifted more than 4 inches from grade or decking. 3. The fence shall be designed and constructed so that it does not allow passage of a 4-inch sphere under any mesh panel. The maximum vertical clearance from the bottom of the mesh fence and the solid surface shall be not greater than 4 inches from grade or decking. 4. An attachment device shall attach each barrier section at a height not lower than 45 inches above grade. Common attachment devices include, but are not limited to, devices that provide the security equal to or greater than that of a hook-and-eye-type latch incorporating a spring-actuated retaining lever such as a safety gate hook. 5. Where a hinged gate is used with a mesh fence, the gate shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool or spa, shall be self-closing and shall have a self- latching device. 6. Patio deck sleeves such as vertical post receptacles that are placed inside the patio surface shall be of a nonconductive material. ISPSC Section 305.2.8, Chain link dimensions. Revise to read as follows: The maximum opening formed by a chain link fence shall be not more than 1¾ inches (44 mm). Where the fence is provided with slats fastened at the top and bottom that reduce the openings, such openings shall be not greater than 1¾ inches (44 mm). The chain link mesh shall be minimum 11 wire gauge. ISPSC Section 305.3.2, Double or multiple gates. Revise to read as follows: If a set of double gates or multiple gates is the only access to the yard area where the swimming pool is located, they shall have not fewer than one leaf secured in place and the adjacent leaf shall be self-closing and be secured with a self-latching device. The gate and barrier shall not have openings larger than ½ inch (12.7 mm) within 18 inches (457 mm) of the latch release mechanism. The self-latching mechanism shall comply with the requirements of Section 305.3.3. If a pedestrian gate is present in conjunction with the double or multiple gates, the double or multiple gates need not be self-closing or self-latching and shall be equipped with a padlock or similar locking device. Where the release mechanism of the latching device is located less than 54 inches (1372 mm) from the bottom of the gate, the release mechanism shall comply with the following: 1. The release mechanism shall be located on the pool side of the gate at least 3 inches (76 mm) below the top of the gate, and 2. The gate and barrier shall have no opening greater than ½ inch (12.7 mm) within 18 inches (457 mm) of the release mechanism. ISPSC Section 305.4, delete this section and replace with the following: 305.4 Secondary protection. 1. Application. The provisions of this section shall apply to swimming pools, spas, hot tubs or other contained bodies of water (above or below ground) when a residence, living area, accessory dwelling unit or accessory building, in which a child younger than six (6) years of age will or does reside, constitutes part of the barrier or enclosure required by Section 305.2: a. Such swimming pool, spa, hot tub or other contained body of water is constructed or installed on or after the effective date of this ordinance at a single family residence; or b. An existing swimming pool or other body of water lawfully constructed prior to the effective date of this ordinance, but which does not conform to these regulations, shall become subject to these regulations as a result of any alteration, addition, or expansion of a dwelling unit, accessory dwelling unit or guest room having access to such pool, that increases the livable area; or c. The existing single family residence is sold. 2. Requirements for secondary protection. When an event described in paragraph (1) above occurs, one of the following methods of secondary protection shall be provided: a. Between the swimming pool or other contained body of water and the residence or living area, a minimum five (5) foot high wall, fence or barrier to the pool area which meets all of the requirements of Sections 305.2 and 305.3; or b. The pool shall be protected by a motorized safety pool cover in compliance with ASTM F1346 which requires the operation of a key switch and which does not require manual operation other than the use of the key switch. The key switch shall be located not less than 54 inches (1372 mm) above the floor or adjacent ground level and where the entire pool cover can be visually inspected; or c. All ground level doors or other doors with direct access to the area containing a swimming pool or other contained body of water shall be equipped with either: (1) a self-closing and self-latching device with the latch located at least 54 inches above the finished floor; or (2) an alarm placed not less than 54 inches above the finished floor which activates automatically whenever the door is opened. The alarm shall sound continuously for a minimum of 30 seconds beginning within the first 7 seconds after the door and its screen, if present, are opened and be capable of providing a sound pressure level of not less than 85 dBA when measured at 10 feet in any direction. The sound of the alarm shall be distinctive from other household sounds such as smoke detectors, telephones, and doorbells. The alarm system may be equipped with a manual means to temporarily deactivate the alarm for a single opening. Such deactivation shall last no longer than 15 seconds. An "off" switch is not acceptable. The deactivation switch shall be located at least 54 inches above the finished floor. Sliding doors shall not form any part of a required barrier unless equipped with a self-closing and self-latching mechanism. Multi-panel sliding doors or walls shall meet the requirements of this section, or shall be secured in place by a permanent fastening method that requires a tool to remove. Emergency escape or rescue windows from sleeping rooms with access to the swimming pool or other contained body of water shall be equipped with a latching device not less than 54 inches above the floor. All other openable dwelling unit or guest room windows with similar access shall be equipped with a screwed-in-place wire mesh screen or a latching device located not less than 54 inches above the floor; or d. An alarm maintained in or on the swimming pool or other body of water. The alarm shall be installed so as to activate automatically whenever a person enters the swimming pool or body of water and remain activated until manually turned off. The alarm shall sound continuously within the first 7 seconds after a person enters the swimming pool or body of water and be capable of providing a sound pressure level of not less than 85 dBA when measured at 10 feet in any direction. The sound of the alarm shall be distinctive from other household sounds such as smoke detectors, telephones, and doorbells; or e. The swimming pool shall be an above-ground swimming pool which has non-climbable exterior sides which are a minimum height of 4 feet. Any access ladder or steps shall be removable without tools and secured in an inaccessible position with a latching device not less than 54 inches above the ground when the pool is not in use; or f. Latching or locking hard safety cover which may be latched or locked shall be deemed to meet all barrier requirements of this section for any spa or hot tub which is not more than 8 feet in width, length or diameter; or g. Alternative protection not specified herein and providing protection meeting the intent of these requirements is allowed when approved by the building official. 3. Compliance. a. All plans submitted to the city for swimming pools to be constructed or installed after the effective date of this section shall specify the manner in which compliance with secondary protection shall be accomplished. Submission of plans shall constitute verification by the contractor and owner of compliance with this section and the manner of compliance. b. If an existing single family residence containing a swimming pool or other body of water is sold after the effective date of this ordinance, and secondary protection is required by this section, the buyer shall comply with the provisions of this section no later than 30 days after the date the buyer takes occupancy of the residence. 4. Maintenance. Secondary protection required by this section shall be maintained in proper operating order by the owner or occupant. ISPSC Section 305. Add the following section: 305.9 Exemptions. The requirements of Section 305 do not apply to the following: a. A system of sumps, irrigation canals, irrigation flood control or drainage works constructed or operated for the purpose of storing, delivering, distributing or conveying water. b. Stock ponds, storage tanks, livestock operations, livestock watering troughs or other structures used in normal agricultural practices. c. Lakes or decorative ponds. ISPSC Section 307.2.2 Materials and Structural Design, Exception is revised to read as follows: Exception: Pools and spas constructed with reinforced concrete or reinforced shotcrete with a minimum compressive strength of 2,500 pounds per square inch when designed by a registered design professional and approved by the building official shall be permitted. ISPSC Section 411.1.4, Public Swimming Pools, Entry and Exit. Revise to read as follows: Swimming pools greater than 20 feet wide in width shall be provided with entries and exits on each side of the deep area of the pool. The entries and exits on the sides of the deep area of a pool shall be located not more than 82 feet apart.
(Ord. No. O25-51, § 1, 12-9-25)
Ask a question about Glendale law
Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.
