§ 99.12.508
Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 99.12.508
Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/e2703e48-fc7f-470d-95a0-62ed63e0b07d
SEC. 99.12.508.
(Amended by Ord. No. 187,719, Eff. 1/23/23.) Section A5.602 of the 2016 CALGreen Code is adopted with amendments to read as follows: TABLE A5.602 CALGREEN VERIFICATION GUIDELINES MANDATORY MEASURES CHECKLIST (Amended by Ord. No. 188,797, Eff. 12/31/25.) {'{'}Click here for a printable PDF version of this table{'}'} Application: This checklist shall be used for nonresidential projects that meet one of the following: new construction, building additions of 1,000 square feet or greater, or building alterations with a permit valuation of $200,000 or more pursuant to Section 301.3 AND do not trigger a Tier 1 or Tier 2 requirement: Y = Yes (section has been selected and/or included) N/A = Not Applicable (code section does not apply to the project – mainly used for additions and alterations) O = Other (provide explanation) [N] = New construction pursuant to Section 301.3 [A] = Additions and/or Alterations pursuant to Section 301.3 CHAPTER 5 DIVISIONS | | SECTION TITLE | CODE SECTION | Y | N/A | O | PLAN SHEET, SPEC, OR ATTACH REFERENCE CHAPTER 5 DIVISIONS | | SECTION TITLE | CODE SECTION | Y | N/A | O | PLAN SHEET, SPEC, OR ATTACH REFERENCE DIVISION 5.1 Planning and Design | Mandatory | Deconstruction and reuse of existing structures, scope with exception | 5.105.1 | | | | Mandatory | Reuse of existing building & verification of compliance with note | 5.105.2 and 5.105.2.1 | | | | Mandatory | Storm water pollution prevention for projects that disturb less than 1 acre of land | 5.106.1 through 5.106.2 | | | | Mandatory | Short-term bicycle parking (with exception) | 5.106.4.1.1 | | | | Mandatory | Long-term bicycle parking | 5.106.4.1.2 through 5.106.4.1.5 | | | | Mandatory | Electric vehicle charging [N] with Section 5.106.3.1, 5.106.5.3.2 and associated Table 5.106.5.3.1 OR Independently Power Allocation Method: Section 5.106. 5.3.6 and associated Table 5.106.5.3.6 | 5.106.5.3.1, 5.106.5.3.2, Table 5.106.5.3.1, 5.106.5.3.2.1, 5.106.5.3.2.2, 5.106.5.3.2.3, 5.106.5.3.2.4, 5.106.5.3.3, 5.106.5.3.4 and 5.106.5.3.5 OR 5.106.5.3.3, 5.106.5.3.4, 5.106.5.3.5, 5.106.5.3.6, Table 5.106.5.3.6, 5.106.5.3.6.1, 5.106.5.3.6.2 and 5.106.5.3.6.3 | | | | Mandatory | Additions or Alterations to existing buildings or parking facilities [A] with Exceptions | 5.106.5.4 | | | | Mandatory | Existing buildings or parking areas without previously installed EV capable infrastructure [A] | 5.106.5.4.1 | | | | Mandatory | Existing buildings or parking areas without previously installed EV capable infrastructure [A] | 5.106.5.4.2 | | | | Mandatory | Electric vehicle (EV) charging: medium-duty and heavy-duty [N] | 5.106.5.5 | | | | Mandatory | Electric vehicle charging readiness requirements for warehouses, grocery stores, office buildings, and manufacturing facilities and retail stores with planned off-street loading spaces [N] | 5.106.5.5.1 | | | | Mandatory | Table 5.106.5.5.1 | 5.106.5.5 and 5.106.5.5.1 | | | | Mandatory | Light pollution reduction [N] (with exceptions, notes and table) | 5.106.8 through 5.106.8.2 | | | | Mandatory | Grading and paving (exception for additions and alterations not altering the drainage path) | 5.106.10 | | | | Mandatory | Heat island effect | 5.106.11 | | | | Mandatory | Hardscape alternatives [N] | 5.106.11.1 | | | | Division 5.2 Energy Efficiency | Mandatory | Meet the minimum energy efficiency standard | 5.201.1 | | | | Division 5.3 Water Efficiency and Conservation | Mandatory | Separate meters (new buildings or additions > 50,000 sf that consume more than 100 gal/day) | 5.303.1.1 | | | | Mandatory | Separate meters (for tenants in new buildings or additions that consume more than 1,000 gal/day) | 5.303.1.2 | | | | Mandatory | Water Reduction | 5.303.2 | | | | Mandatory | Water closets shall not exceed 1.28 gallons per flush (gpf) | 5.303.3.1 | | | | Mandatory | Wall-mounted urinals shall not exceed 0.125 gpf | 5.303.3.2.1 | | | | Mandatory | Floor-mounted urinals shall not exceed 0.5 gpf | 5.303.3.2.2 | | | | Mandatory | Single showerhead shall have maximum flow rate of 1.8 gpm (gallons per minute) at 80 psi | 5.303.3.3.1 | | | | Mandatory | Multiple showerheads serving one shower shall have a combined flow rate of 1.8 gpm at 80 psi | 5.303.3.3.2 | | | | Mandatory | Nonresidential lavatory faucets | 5.303.3.4.1 | | | | Mandatory | Kitchen faucets | 5.303.3.4.2 | | | | Mandatory | Wash fountains | 5.303.3.4.3 | | | | Mandatory | Metering faucets | 5.303.3.4.4 | | | | Mandatory | Metering faucets for wash fountains | 5.303.3.4.5 | | | | Mandatory | Pre-rinse spray valve | 5.303.3.4.6 | | | | Mandatory | Food waste disposers | 5.303.4.1 | | | | Mandatory | Areas of additions or alterations | 5.303.5 | | | | Mandatory | Standards for plumbing fixtures and fittings | 5.303.6 | | | | Mandatory | Outdoor potable water use in landscape areas (with notes) | 5.304.1 | | | | Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Weather protection | 5.407.1 | | | | Mandatory | Moisture control: sprinklers | 5.407.2.1 | | | | Mandatory | Moisture control: exterior door protection | 5.407.2.2.1 | | | | Mandatory | Moisture control: flashing | 5.407.2.2.2 | | | | Mandatory | Construction waste management – comply with either: Sections 5.408.1.1, 5.408.1.2, 5.408.1.3 or more stringent local ordinance | 5.408.1.1, 5.408.1.2, 5.408.1.3 | | | | Mandatory | Construction waste management: documentation | 5.408.1.4 | | | | Mandatory | Universal waste [A] | 5.408.2 | | | | Mandatory | Excavated soil and land clearing debris (100% reuse or recycle) | 5.408.3 | | | | Mandatory | Life cycle assessment, scope, whole building life cycle assessment with notes, building components, reference study period, and verification of compliance | 5.409.1, 5.409.2, 5.409.2.1, 5.409.2.2 and 5.409.2.3 | | | | Mandatory | Life cycle assessment, scope, product GWP compliance – prescriptive path, 5.409.3.1 with exception and exception equation, verification of compliance and product GWP limits table with footnotes | 5.409.1, 5.409.3, 5.409.3.1, 5.409.3.2 and Table 5.409.3 | | | | Mandatory | Recycling by occupants (with exception) | 5.410.1 | | | | Mandatory | Recycling by occupants: additions (with exception) | 5.410.1.1 | | | | Mandatory | Recycling by occupants: sample ordinance | 5.410.1.2 | | | | Mandatory | Commissioning new buildings (≥ 10,000 sf) [N] | 5.410.2 | | | | Mandatory | Owner’s or owner representative’s Project Requirements (OPR) [N] | 5.410.2.1 | | | | Mandatory | Basis of Design (BOD) [N] | 5.410.2.2 | | | | Mandatory | Commissioning plan [N] | 5.410.2.3 | | | | Mandatory | Functional performance testing [N] | 5.410.2.4 | | | | Mandatory | Documentation and training [N] | 5.410.2.5 | | | | Mandatory | Systems manual [N] | 5.410.2.5.1 | | | | Mandatory | Systems operation training [N] | 5.410.2.5.2 | | | | Mandatory | Commissioning report [N] | 5.410.2.6 | | | | Mandatory | Testing and adjusting for new buildings < 10,000 sf or new systems that serve additions or alterations [A] | 5.410.4 | | | | Mandatory | System testing plan for renewable energy, landscape irrigation and water reuse [A] | 5.410.4.2 | | | | Mandatory | Procedures for testing and adjusting | 5.410.4.3 | | | | Mandatory | Procedures for HVAC balancing | 5.410.4.3.1 | | | | Mandatory | Reporting for testing and adjusting | 5.410.4.4 | | | | Mandatory | Operation and maintenance (O&M) manual | 5.410.4.5 | | | | Mandatory | Inspection and reports | 5.410.4.5.1 | | | | Division 5.5 Environmental Quality | Mandatory | Fireplaces | 5.503.1 | | | | Mandatory | Woodstoves | 5.503.1.1 | | | | Mandatory | Temporary ventilation | 5.504.1 | | | | Mandatory | Covering of ducts openings and protection of mechanical equipment during construction | 5.504.3 | | | | Mandatory | Adhesives, sealants and caulks | 5.504.4.1 | | | | Mandatory | Paints and coatings | 5.504.4.3 | | | | Mandatory | Aerosol paints and coatings | 5.504.4.3.1 | | | | Mandatory | Aerosol paints and coatings: verification | 5.504.4.3.2 | | | | Mandatory | Carpet systems | 5.504.4.4 | | | | Mandatory | Carpet cushion | 5.504.4.4.1 | | | | Mandatory | Carpet adhesives per Table 5.504.4.1 | 5.504.4.4.2 | | | | Mandatory | Composite wood products | 5.504.4.5 | | | | Mandatory | Composite wood products: documentation | 5.504.4.5.3 | | | | Mandatory | Resilient flooring systems | 5.504.4.6 | | | | Mandatory | Resilient flooring: verification of compliance | 5.504.4.6.1 | | | | Mandatory | Thermal insulation | 5.504.4.7 | | | | Mandatory | Verification of compliance | 5.504.4.7.1 | | | | Mandatory | Acoustical ceilings and wall panels | 5.504.4.8 | | | | Mandatory | Verification of compliance | 5.504.4.8.1 | | | | Mandatory | Filters (with exceptions) | 5.504.5.3 | | | | Mandatory | Filters: labeling | 5.504.5.3.1 | | | | Mandatory | Environmental tobacco smoke (ETS) control | 5.504.7 | | | | Mandatory | Indoor moisture control | 5.505.1 | | | | Mandatory | Outside air delivery | 5.506.1 | | | | Mandatory | Carbon dioxide (CO2) monitoring | 5.506.2 | | | | Mandatory | Carbon dioxide (CO2) monitoring in classrooms | 5.506.3 | | | | Mandatory | Acoustical control (with exception) | 5.507.4 | | | | Mandatory | Exterior noise transmission, prescriptive method (with exceptions) | 5.507.4.1 | | | | Mandatory | Noise exposure where noise contours are not readily available | 5.507.4.1.1 | | | | Mandatory | Performance method | 5.507.4.2 | | | | Mandatory | Site features | 5.507.4.2.1 | | | | Mandatory | Documentation of compliance | 5.507.4.2.2 | | | | Mandatory | Interior sound transmission (with note) | 5.507.4.3 | | | | Mandatory | Ozone depletion and greenhouse gas reductions | 5.508.1 | | | | Mandatory | Chlorofluorocarbons (CFCs) | 5.508.1.1 | | | | Mandatory | Halons | 5.508.1.2 | | | | Mandatory | Supermarket refrigerant leak reduction for retail food stores 8,000 square feet or more Sections 5.508.2 through 5.508.2.6.3 | 5.508.2 through 5.508.2.6.3 | | | | | END OF MANDATORY PROVISIONS | | | | | Documentation Author's / Responsible Designer's Declaration Statement __ Mandatory: I attest that this mandatory provisions checklist is accurate and complete. Signature: Company: | Date: Address: | License: City/State/Zip: | Phone:
Ask a question about Los Angeles law
Corpus searches the Los Angeles sections it holds and shows the ones that match, with their citations. Free, no sign-in.
