Sec. 49-2233. - Installation.
(a) All rainwater drainage piping shall comply with article XIII of this chapter except as modified herein. (b) All water piping shall comply with article XV of this chapter except as modified herein. (c) Hose bibs on the piping system are prohibited. (d) All water piping shall be separate and independent of any potable water system. (e) Any building using rainwater harvesting shall install a master backflow assembly on the water service after the meter. Makeup water to the reservoir shall be through a reduced pressure principal backflow preventer assembly installed at the point of connection with the potable water system or an air gap into a holding tank and then pumped into the reservoir. (See Figure 49-2205.)
(Ord. No. 40524, § 1, 10-20-15)