33.120.230 Building Length and Façade Articulation

A. Purpose. These standards, along with the height and setback standard, limit the bulk of buildings close to the street. These standards help ensure that large buildings will be divided into smaller components that relate to the scale and development patterns of Portland’s multi-dwelling residential areas and add visual interest and variety to the street environment. B. Maximum building length. In the RM1, RM2, and RMP zones, the maximum building length for the portion of buildings located within 30 feet of a street lot line is 100 feet. The portions of buildings subject to this standard must be separated by a minimum of 10 feet. See Figure 120-8. Manufactured dwelling parks are exempt from this standard. Figure 120-8 Maximum Building Length

![](https://figures.74-208-44-221.nip.io/portland/20261114/d4b5c1f93ac3d6876cb47ce3bcd19e267f5b04de996a22577a45c473fa368c06.png)

![Figure 120-8 Maximum Building Length](https://figures.74-208-44-221.nip.io/portland/20261114/538b303d44f393f26593949dc27ae2ad0d203d8d68fd98abe9bd4818681a1274.png)

C. Facade articulation 1. Where the standard applies. This standard applies in the RM2 through RM4 zones as follows. Development that includes a residential use is exempt from this standard until January 1, 2029: a. In the RM2 zone, the standard applies to buildings more than 35 feet high that have facade areas of more than 3,500 square feet within 20 feet of a street property line. b. In the RM3 and RM4 zones, the standard applies to buildings more than 45 feet high that have facade areas of more than 4,500 square feet within 20 feet of a street property line. c. Portions of building facades that are vertically separated by a gap of at least 10 feet in width extending at least 30 feet in depth from the street property line are considered to be separate facades areas for the purposes of the facade area measurements. See Figure 120-8. 2. The standard. At least 25 percent of the area of a street-facing facade within 20 feet of a street lot line must be divided into facade planes that are off-set by at least 2 feet in depth from the rest of the facade. Facade area used to meet the facade articulation standard may be recessed behind, or project out from, the primary facade plane, but projections into street right-of-way, and balconies that do not count toward floor area do not count toward meeting this standard. See Figure 120-9. Figure 120-9 Facade Articulation

![](https://figures.74-208-44-221.nip.io/portland/20261114/db4d9ee1fd3fcd6fc83522162cf6a94e1422b7d6d056615231bd68e48b02a3ab.png)

![Figure 120-9 Facade Articulation](https://figures.74-208-44-221.nip.io/portland/20261114/71b79a285048443e2045b01a54cb46e3476c036b28d5fa43fc527301bb9ce925.png)

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.