§ 5.5.07 — Building Element Requirements
Code of the City of Grand Rapids, Michigan (Supp. No. 70: codified through Ordinance No. 2026-08, enacted April 14, 2026) · Grand Rapids City Code § 5.5.07
Corpus is an independent public-information project, not the official City of Grand Rapids website. Stable reference: corpuslaw.us/code/e4ce9dba-3e48-4116-8d9e-0e02f5cea4d7
Sec. 5.5.07. - Building Element Requirements.
A. Building Elements Table. All development in the Residential Zone Districts shall comply with the requirements in Table 5.5.07.A. Building Elements unless otherwise expressly stated, or unless a different requirement is contained in an applicable Overlay District. Table 5.5.07.A. Building Elements: Residential Zone Districts Neighborhood Classification | TN | MCN | MON | Use or Other Regulations Zone District | LDR | MDR | LDR | MDR | LDR | MDR Maximum Height Residential Permitted Use | Stories | 2 ½ | 3 | 2 ½ | 3 | 2 ½ | 3 ½ | 5.5.07.B.1. Feet | 35 | 45 | 35 | 45 | 35 | 52 Residential SLU | Stories | 3 | 4 | 3 | 6 | 3 | 8 | 5.5.07.B.2 Feet | 45 | 60 | 45 | 90 | 45 | 120 Non-Residential | Stories | 3 | 3 | 3 | 3 | 3 | 3 ½ | 5.5.07.B.1. Feet | 45 | 45 | 45 | 45 | 45 | 52 Materials Residential | R | R | R | R | R | R | 5.5.07.C. Non-residential | R | R | R | R | R | R Façade Variation Multiple-Family and Non-residential | R | R | R | R | — | — | 5.5.07.D. Building Orientation | R | R | R | R | — | — | 5.5.07.E. Entrance | R | R | R | R | — | — | 5.5.07.E. Transparency (% of building wall area) Front | All residential | 20 | 20 | 15 | 15 | 15 | 15 | 5.5.07.F. Side | Detached, attached single-family | 3 windows minimum at 6 sq. ft. each | — Two-family, multiple-family | 10 | 10 | 10 | 10 | 10 | 10 | — Non-Residential | Front | 40 | 40 | 40 | 40 | 40 | 40 | — Side | 20 | 20 | 20 | 20 | 10 | 10 | — Transitional Features | R | R | R | R | R | R | 5.5.07.G. Streetscape Design | R | R | R | R | R | R | 5.11.13. S = Special Land Use; R = Rules Apply; "-" = Not Applicable. B. Building Height. 1. See Section 5.2.06. Building Height for additional information and exceptions. In keeping with the character of the TN Neighborhood Classification the entire height of the first floor or ground floor shall be at or above grade. 2. Residential building heights may be increased from the requirements of Table 5.5.07.A. by Special Land Use approval. The Planning Commission shall take into consideration the neighborhood context, scale, massing and compatibility of the proposed structure in making its decision. C. Materials. 1. Permitted Materials. a. Durable building materials, simple configurations and solid craftsmanship are required. b. Walls visible from public streets, exclusive of wall areas devoted to meeting transparency requirements, shall be constructed of: high quality, durable materials, including: brick; fiber cement siding, high-quality finished metal; wood lap, aluminum or vinyl siding; and split-faced block, stucco or stone. c. EIFS is permitted for accents only. d. To provide visual depth and strong shadow lines, clapboard siding must have a minimum butt thickness of a quarter (¼) of an inch. 2. Where more than one (1) façade material is proposed vertically, the 'heavier' material in appearance shall be incorporated below the 'lighter' material (e.g. masonry below siding). 3. Roofing Materials. a. Roofing materials shall be those used and installed in a manner customary for residential construction, shall be compatible in character and scale with the residential structure on which it is being installed, shall be installed according to the manufacturer's specifications, shall have no visible fasteners, and shall be uniform in type and appearance within each uninterrupted roof plane. b. Acceptable roof materials include three hundred (300) pound or better, dimensional asphalt composite shingles, wood shingles and shakes, metal tiles or standing seam, slate, and ceramic tile. The approving authority may permit "engineered" wood or slate with an approved sample and examples of successful, high quality local installations. c. Corrugated roofing materials are not permitted. 4. Repairs and replacements shall be completed with materials similar in color and appearance to the existing materials. 5. Orientation. Building materials in TN Zone Districts shall have a traditional, horizontal orientation. 6. Administrative Departure. Other materials of equivalent or better quality, including high quality synthetic materials, may be approved, if determined appropriate for the building, site, and area with an approved sample and examples of successful, high quality local installations. D. Façade Variation. The following requirements shall apply to multiple-family dwellings and non-residential buildings in Zone Districts within TN and MCN Neighborhood Classifications. 1. Uninterrupted Façade. The maximum linear length of an uninterrupted building façade facing a public street and/or park shall be thirty (30) feet. Building wall offsets (projections and recesses), cornices, plinths, quoins, varying building materials or pilasters shall be used to break up the mass of a single building. 2. Vents, air conditioners and other utility elements shall not be part of any street-facing building façade. Where these elements are part of other façades, particular care must be taken to render these elements less visible to public view through architectural integration or other means of screening. 3. Administrative Departures. Administrative Departures may be granted for: a. A reduction of up to five (5) feet of the thirty (30) foot requirement may be approved, depending on actual building design, entrance placement, and other factors that make the requirement impractical. b. Other methods to provide adequate articulation, provided that the visual effect of articulation is maintained. Examples of acceptable variations may include architectural or artistic details or features, a variation in color or materials and enhanced ornamentation around building entranceways. c. Locations of vents, air conditioners, and other utility elements where physical conditions of the site dictate a location on the street-facing façade. E. Entrances. 1. Orientation. a. Interior Lots. For interior lots, the primary building entrance shall be located in the front façade parallel to the street or urban open space. b. Corner Lots. For corner lots, the primary entrance shall face the street from which the structure derives its street address. However, two-family dwellings shall have a separate primary entrance per dwelling unit, with only one primary entrance per street. c. Administrative Departure. Alternative orientations may be considered where consistent with existing adjacent development or practical considerations based on existing structure layout. 2. Primary Entrances. Primary entrances for all residential structures shall be clearly defined by at least one (1) of the following: a. A projecting or recessed entrance. A recessed entrance is required if the entrance is within five (5) feet of the lot line; the entrance recess shall not be less than the width of the door(s) when opened outward. b. Stoop or enclosed or covered porch, provided that an enclosed porch shall comply with required setbacks, except as provided in E.3. below. c. Transom and/or side light window panels framing the door opening. d. Architectural trim framing the door opening. e. Administrative Departure. Other methods, such as unique color treatments, additional moldings with expression lines, or bays of unique width, may be approved with an Administrative Departure provided the same effect is achieved. 3. TN Neighborhood Classification - Porches and Stoops. In addition to the above, residential dwellings located in Zone Districts within the TN Neighborhood Classification shall be subject to Section 5.2.07.F. and the following requirements: a. The primary entrance facing the street shall include a stoop or a front porch. b. Projections into RBLs and Front Yards. i. For lots with an RBL, a stoop may be built up to six (6) feet (not including steps) forward of the RBL, and shall be at least three (3) feet wide. An unenclosed front porch may be built up to six (6) feet (not including steps) forward of the RBL. ii. For lots with a setback, an unenclosed porch or stoop (not including steps) may project into the front yard by no more than ten (10) feet, but shall be no closer than five (5) feet to the front sidewalk. c. Porches, not including steps, shall be at least six (6) feet deep to provide for usable seating and circulation, and be at least one-third (⅓) the width of the front façade of the residential structure (not including the garage), but in no case shall be less than eight (8) feet wide. d. Building materials shall be compatible with the main building. e. Porch fixtures such as columns, pillars, posts and railings shall be coated with stain or paint if materials made of wood are used. f. Administrative Departures may be granted for the following. i. A decrease in the required porch projection up to two (2) feet if, due to required building setbacks, the required projection cannot be satisfied. ii. Porch or entrance enclosures may be permitted where individual site conditions dictate the need for enclosure or where the enclosure and its placement is consistent with others on the same block face, for the same use and in the same Zone District. In all cases, at least eighty (80) percent transparency shall be maintained. iii. Entrances to dwellings to accommodate persons with mobility impairments. 4. Non-Residential Structures. Non-residential structures in Residential Zone Districts shall comply with the requirements of Section 5.6.08.F. for entrances. F. Transparency. 1. General Requirements. The General Provision requirements of Section 5.2.14. Building Transparency shall apply. 2. Residential Buildings. Residential buildings shall have windows on all exterior walls of the structure. The size and placement of windows on the façade shall be generally uniform. a. TN Residential Dwellings. For all residential dwellings in Zone Districts within the TN Neighborhood Classification, at least twenty (20) percent of the area of the front façade shall consist of windows or primary entrance doors which permit a view from the dwelling to the street. b. MCN and MON Residential Dwellings. For all residential dwellings in Zone Districts within MCN and MON Neighborhood Classifications, at least fifteen (15) percent of the area of the front façade shall consist of windows or primary entrance doors which permit a view from the dwelling to the street. c. Single-Family Detached and Attached Dwellings (e.g. row houses and townhouses). i. At least three (3) windows with a minimum of six (6) square feet each are required on the building's side walls (those adjoining the front façade). ii. Administrative Departure. An Administrative Departure may be granted for side wall transparency for single-story dwellings where it is determined that the requirement cannot be met due to the interior design of the dwelling. d. Two-Family and Multiple-Family Dwellings. For two-family dwellings and multiple-family dwellings, at least ten (10) percent of the area of the building's side walls (those adjoining the front façade) shall consist of windows. 3. Non-Residential Buildings. a. For non-residential building façades facing public streets, parks and through block walkways, at least forty (40) percent of the façade area shall consist of window and door openings. b. In the TN and MCN Neighborhood Classifications, at least twenty (20) percent of the area of a building's side walls (those adjoining the front façade) must consist of windows. c. In the MON Neighborhood Classification, at least ten (10) percent of the area of a building's side walls (those adjoining the front façade) must consist of windows. G. Transitional Features. 1. Purpose. Transitional features are architectural elements, site features and alterations to building massing that are used to provide a transition between higher intensity uses and low- or moderate-density residential uses. These features assist in mitigating potential conflicts between those uses in lieu of conventional landscape buffers or large setbacks. It is the intent of these standards to: a. Reduce land consumption; b. Create a compatible mixed-use environment; c. Limit interruptions in vehicular and pedestrian connections created by efforts to segregate densities and uses; and d. Establish or maintain vibrant pedestrian- and transit-oriented areas where differing uses and densities can operate in close proximity to one another. 2. Applicability. Transitional features shall be required in the following circumstances. a. Where buildings or structures would be one (1) or more stories higher than adjacent residential buildings or structures. b. Where non-residential uses are situated adjacent to residential buildings or structures. c. Where higher-intensity land uses that would adversely affect the livability of an area. d. As a condition of any zoning approval required by Article 12 when necessary to ensure that the appropriate review standards are satisfied. 3. Transitional Features. The following transitional features may be required either singly or in combination. a. Landscape Buffer. The Director or approving body for a required zoning approval, as applicable, may require the use of a landscape buffer (Section 5.11.12.) in lieu of, or in addition to, a transitional feature where such landscape buffer would be sufficient to reduce potentially adverse impacts between incompatible uses, densities or different building types. b. Uses. A continuum of use intensity, where moderate intensity uses are sited between high-intensity uses and low-intensity uses, may be required for multi-building developments on one (1) or more lots. An example would be a duplex between a single-family home and an apartment building. c. Height and Massing. Building height and massing shall be reduced in the form of building step-backs, recess lines or other techniques so that large structures are compatible in scale with smaller, adjacent structures. d. Architectural Features. Similarly sized and patterned architectural features such as windows, doors, arcades, pilasters, cornices, wall offsets, building materials, and other building articulations included on the lower-intensity use shall be incorporated as transitional features. 4. Parking and Loading. Where possible, off-street parking, loading, service and utility areas shall be located away from a lower-intensity use.
(Ord. No. 2018-62, § 1, 10-23-18; Ord. No. 2019-09, § 5, 3-26-19)
Ask a question about Grand Rapids law
Corpus searches the Grand Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.
