§ 33.110.220 — Setbacks
Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.110.220
Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/e4eb94ac-90db-4882-adb8-b2fc6b659b4c
33.110.220 Setbacks
A. Purpose. The setback regulations for buildings and garage entrances serve several purposes: • They maintain light, air, separation for fire protection, and access for fire fighting; • They reflect the general building scale and placement of residences in the city's single- dwelling neighborhoods; • They foster a reasonable physical relationship between residences; • They promote options for privacy for neighboring properties; • They require larger front setbacks than side and rear setbacks to promote open, visually pleasing front yards; • They provide adequate flexibility to site a building so that it may be compatible with the neighborhood, fit the topography of the site, allow for required outdoor areas, and allow for architectural diversity; and • They provide room for a car to park in front of a garage door without overhanging the street or sidewalk, and they enhance driver visibility when backing onto the street. B. Required setbacks. The required setbacks for buildings and garage entrances are stated in Table 110-4. The walls of the garage structure are subject to the front, side, and rear building setbacks stated in Table 110-4. The minimum setbacks for institutional uses are stated in 33.110.270, Institutional Development Standards. Other setbacks may apply to specific types of development or situations. C. Extensions into required building setbacks. 1. The following features of a building may extend into a required building setback up to 20 percent of the depth of the setback. However, the feature must be at least three feet from a lot line: a. Chimneys, fireplace inserts and vents, mechanical equipment, and fire escapes; b. Water collection cisterns and stormwater planters that do not meet the standard of Paragraph C.3; c. Decks, stairways, wheelchair ramps and uncovered balconies that do not meet the standards of Paragraph C.3; and d. Bays and bay windows that meet the following requirements: (1) Each bay and bay window may be up to 12 feet long, but the total area of all bays and bay windows on a building facade cannot be more than 30 percent of the area of the facade; (2) At least 30 percent of the area of each bay which faces the property line requiring the setback must be glazing or glass block; and (3) Bays and bay windows must cantilever beyond the foundation of the building. 2. Building eaves may extend up to 2 feet into a required building setback provided the eave is at least three feet from a lot line. 3. The following minor features of a building may extend into the entire required building setbacks: a. Utility connections attached to the building that are required to provide services such as water, electricity, and other similar utility services; b. Gutters and downspouts that drain stormwater off a roof of the structure; c. Stormwater planters that are no more than 2-1/2 feet above the ground; d. Water collection cisterns that are 6 feet or less in height; e. Decks, stairs and ramps that are no more than 2-1/2 feet above the ground. However, stairways and wheelchair ramps that lead to one entrance on the street-facing façade of a building are allowed to extend into the required setback from a street lot line regardless of height above ground; and f. On lots that slope down from the street, vehicular or pedestrian entry bridges that are no more than 2-1/2 feet above the average sidewalk elevation. 4. Detached accessory structures. The setback standards for detached accessory structures, including detached mechanical equipment, are stated in 33.110.245. Fences are addressed in 33.110.275. Detached accessory dwelling units are addressed in Chapter 33.205. D. Exceptions to the required setbacks. 1. Setback averaging. The front building setback, and the setback of decks, balconies, and porches may be reduced to the average of the respective setbacks on the abutting lots. See Chapter 33.930, Measurements, for more information. 2. Flag lots. The lot in front of a flag lot may reduce its side building setback along the flag pole lot line to zero. All other setback requirements remain the same. 3. Environmental zone. The front building and garage entrance setback may be reduced to zero where any portion of the site is in an environmental overlay zone. Where a side lot line is also a street lot line the side building and garage entrance setback may be reduced to zero. All other provisions of this Title apply to the building and garage entrance. 4. Steeply sloping lots. This provision applies to lots that slope up or down from the street with an average slope of 20 percent or greater. See Chapter 33.930, Measurements, for more information on how to measure average slope. a. In the RF, R20, R10, and R7 zones, the front building setback for the dwelling may be reduced to 10 feet. However, the height limitations of subparagraph c. apply. See Figures 110-2 and 110-3. b. In all single-dwelling residential zones, the front building setback for the garage wall and/or the garage entrance setback may be reduced to five feet. However, the height limitations of Paragraph D.4.c. apply. See Figures 110-2 and 110-3. c. Height limitation. The height limit in the area of the reduced setback is lowered one foot for every foot of reduced setback. See Figures 110-2 and 110-3. 5. Established building lines. The front, side, or rear building setback for the primary structure may be reduced for sites with existing nonconforming development in a required setback. The reduction is allowed if the width of the portion of the existing wall of the primary structure within the required setback is at least 60 percent of the width of the respective facade of the existing primary structure. The building line created by the nonconforming wall serves as the reduced setback line. Eaves associated with the nonconforming wall may extend the same distance into the reduced setback as the existing eave. However, side or rear setbacks may not be reduced to less than 3 feet in depth and eaves may not project closer than 2 feet to the side or rear property line. See Figure 110-4. This reduced setback applies to alterations that are no higher than the existing nonconforming wall. For example, a second story could not be placed up to the reduced setback line if the existing nonconforming wall is only one story high. 6. Split zoning. No setbacks are required from an internal lot line that is also a zoning line on sites with split zoning. 7. Land divisions and Planned Developments with existing development. The following setback reductions are allowed when proposed as part of a land division or Planned Development: a. The minimum setback between an existing building and a side lot line along a proposed right-of-way dedication or street tract may be reduced to three feet; b. When a dedication of public right-of-way along the frontage of an existing street is required as part of a land division or Planned Development, the minimum front or side setback between an existing building and a lot line that abuts the right-of- way may be reduced to zero. Future additions or development must meet required minimum setbacks. c. Eaves on an existing building may extend one foot into the reduced setback allowed by D.7.a. or b., except they may not extend into the right-of-way. 8. Required dedication. When a dedication of public right-of-way along the frontage of an existing street is required by a public agency, the minimum front or side setback between an existing building and a lot line that abuts the right-of-way may be reduced to zero. Future additions or development must meet required minimum setbacks. Eaves on an existing building may extend one foot into the reduced setback except they may not extend into the right-of-way. 9. Alley. No side, rear, or garage entrance setback is required from a lot line abutting an alley. Figure 110-2 Exceptions To Front Building Setback And Garage Entrance Setback—Downhill


Figure 110-3 Exceptions To Front Building Setback And Garage Entrance Setback—Uphill


Figure 110-4 Established Building Lines


Ask a question about Portland law
Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.