§ 18.41.110 — Amend CRC Section R403.1.5—Slope
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.41.110
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/e4f50427-bac6-4d3e-acc7-26fcdd24ed88
18.41.110 - Amend CRC Section R403.1.5—Slope.
Section R403.1.5 of the California Residential Code is amended to read as follows: R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10-percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10-percent slope). For structures located in Seismic Design Categories D 0 , D 1 or D 2 , stepped footings shall be reinforced with four ½-inch diameter (12.7 mm) deformed reinforcing bars. Two bars shall be place at the top and bottom of the footings as shown in Figure R403.1.5. [image omitted; see the official code] FIGURE R403.1.5 STEPPED FOOTING
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019)