11-21-3: - DEVELOPMENT STANDARDS
A. Unless specifically modified by the City Council, the specified development standards are based upon the requirements of the underlying base zoning district; including but not limited to minimum lot area, maximum density, maximum building height, minimum setbacks, and maximum lot coverage for each underlying zoning district.
B. The City Council may approve modifications to the underlying district standards proportionate to number of items and degree of compliance provided by projects that comply either with a combination of Items 1 and 2, below; or with a combination of 1 and 3, below. Projects with few modifications need comply with a lower percentage of criteria. Projects with a higher number and greater deviation from adopted standards shall comply with a higher percentage of criteria.
1. Provide distinctive, superior quality designs. (See Section 11-31-32, Superior Design)
2. Address environmental performance standards outlined below:
a. Site selection criteria. Sites shall meet one or more of the following criteria.
i. Redevelop and rehabilitate economically distressed properties (particularly greyfield sites), damaged sites or environmentally contaminated 'brownfield' sites.
ii. Utilize areas with existing utility and transportation infrastructure and existing community services. This criterion is preferred for higher density and higher intensity development, when feasible.
iii. Utilize locations within ½ mile of a planned light rail line or ¼ mile from an existing or planned bus stop. This criterion is preferred for higher density and higher intensity development, when feasible
b. Site design criteria. Designing the site to facilitate alternative modes of transportation and to reduce onsite environmental impacts.
i. Provide safe and secure storage for bicycles. For commercial, employment or institutional projects, bicycle storage areas shall be within 200 yards of the building entrance, and shall have a designated and convenient pedestrian access route connecting the storage area to the building. For residential projects, safe and secure bicycle storage areas shall be provided on-site for a minimum 15% of the residents.
ii. Include priority location parking for low-emission vehicles in parking areas.
iii. Provide priority location parking spaces for carpool or vanpool vehicles.
iv. Provide the number of parking spaces designed to serve a development site consistent with the number of spaces required to meet the minimum parking ratio. Parking spaces over the minimum number is discouraged.
v. For greenfield sites, protect or restore natural areas on site with native vegetation to encourage biodiversity and for enjoyment by people. For previously developed sites, restore areas with native or adapted vegetation to encourage biodiversity and for enjoyment by people. The size of the space should be appropriate for the size of the site and the activity level or use of the site.
vi. Design the project to be energy efficient including, but not limited to, designed to reduce summer heat gain, reduce winter heat loss, utilize day lighting strategies and provide the opportunity for occupants to take advantage of renewable energy. The design also mitigates the effects of solar exposure for users and pedestrians. For purposes of this criterion, buildings that have efficient HVAC systems, incorporate passive solar heating, cooling and day lighting strategies within an efficient building envelope, as recommended by the Department of Energy's Energy Efficiency and Renewable Energy (EERE) section, including buildings designed to earn the EPA ENERGY STAR or designed to meet LEED™ Silver or equivalent third-party criteria are considered to be energy efficient and no higher standard shall be used
c. Provide documented evidence that the building(s) will meet or exceed nationally recognized environmental performance standards. For purposes of this criterion, buildings that are designed to earn LEED™ Silver, Green Globes, and/or equivalent third-party criteria, and no higher standard shall be required. Avoid sites considered inappropriate, such as prime farmland, land identified as habitat for endangered species, and wetlands or riparian areas associated with wildlife.
d. Utilize areas with existing utility and transportation infrastructure and existing community services. This criterion is preferred for higher density and higher intensity development, when feasible.
e. Redevelop and rehabilitate economically distressed properties (particularly greyfield sites), damaged sites or environmentally contaminated 'brownfield' sites.
f. Utilize locations within ½ mile of a planned light rail line or ¼ mile from an existing or planned bus stop. This criterion is preferred for higher density and higher intensity development, when feasible.
3. Provide documented evidence that the building(s) will meet or exceed nationally recognized environmental performance standards. For purposes of this criterion, buildings that are designed to earn Green Globes, LEED™ Silver, or to be in compliance with the International Green Construction Code and/or equivalent third-party criteria, are considered to be energy efficient and no higher standard shall be required.