For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14.04.095 — Section 1704.6.1 of the 2025 Edition of the California Building Code is amended to read as follows

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.095

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/e6bff25e-397a-4894-ab8a-26867b5ceb62

14.04.095 - Section 1704.6.1 of the 2025 Edition of the California Building Code is amended to read as follows.

1704.6.1 Structural observations for structures. Structural observations shall be provided for those structures where one or more of the following conditions exist: 1. The structure is classified as Risk Category III or IV. 2. The structure is a high-rise building. 3. The structure is assigned to Seismic Design Category E, and is greater than two stories above grade plane. 4. Such observation is required by the registered design professional responsible for the structural design. 5. Such observation is specifically required by the building official. 6. A lateral design is required for the structure or portion thereof. Exception: One-story wood framed Group R-3 and Group U Occupancies less than 2,000 square feet in area, provided the adjacent grade is not steeper than 1 unit vertical in 10 units horizontal (10% sloped), assigned to Seismic Design Category D.

(Ord. No. 7461, § 5, 11-10-2025)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.