§ 33.270.200 — Additional requirements for Planned Developments in the R20 through R5 Zones
Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.270.200
Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/e7f3c3b5-55de-4747-9c77-89107ad4797c
33.270.200 Additional requirements for Planned Developments in the R20 through R5 Zones
A. Where this standard applies. In the R20 through R5 zones, unless exempted by Subsection C., the standards of this section apply when the total number of proposed dwelling units is at least 75 percent of the maximum number of dwelling units allowed through the Planned Development, B. Visitability. At least 33 percent of the dwelling units on the Planned Development site must meet the following standards: 1. Visitable entrance. At least one entrance must be accessible via a route that does not have any stairs between it and the street lot line or an on-site parking space. The slope of the route may not exceed 1:8. 2. Visitable bathroom. At least one bathroom with a sink and toilet must be designed to accommodate an unobstructed circle that is at least 60-inches in diameter. As an alternative, the bathroom may be designed to accommodate an unobstructed area that is comprised of two rectangles that are at least 36 inches by 60 inches, and oriented at right angles to each other. See Figure 270-1. The visitable bathroom must be on the same floor as the visitable entrance or be accessible from the visitable entrance via a ramp, elevator or lift. Adjustments are prohibited; 3. Visitable living area. There must be at least 200 square feet of living area on the same floor as the visitable entrance or 200 square feet of living area must be accessible from the visitable entrance via a ramp, elevator or lift. Adjustments are prohibited; and 4. Visitable doors. All door openings between and including the visitable entrance, visitable living area, and the visitable bathroom must be at least 34 inches wide. Adjustments are prohibited. C. Exemptions. The following are exempt from the standards of Subsection B: 1. Sites with an average slope of 20 percent or greater 2. Sites where fewer than 3 units are proposed. 3. Sites with a concurrent land division where no multi-dwelling development or multi dwelling structures are proposed. For these sites, the visitability standards are applied to each lot according to 33.110.265.E.3. at the time of development. Figure 270-1 Visitable Bathroom Clearances




Ask a question about Portland law
Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
