§ 31-72 — NEC Chapter 2 WIRING AND PROTECTION - amendments

Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-72

Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/e8262450-1546-43ed-9f89-0b0e9227bb9c

Sec. 31-72. - NEC Chapter 2 WIRING AND PROTECTION - amendments.

(a) Subsections (2), (3), (4), (5), (6) and (7) of 250.118 Types of Equipment Grounding Conductors, are amended to read as follows, and paragraph d. of subsection (5) is deleted: 250.118 Types of Equipment Grounding Conductors. (2) Rigid metal conduit, with an individual equipment grounding conductor. (3) Intermediate metal conduit, with an individual equipment grounding conductor. (4) Electrical metallic tubing, with an individual equipment grounding conductor. (5) Listed flexible metal conduit (with an individual equipment grounding conductor) meeting all of the following conditions: a. The conduit is terminated in listed fittings. b. The circuit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less. c. The combined length of flexible metal conduit, flexible metallic tubing and liquid-tight flexible metal conduit in the same effective ground-fault current path does not exceed 1.8 m (6 ft). (6) Listed liquid-tight flexible metal conduit (with an individual equipment grounding conductor) meeting all of the following conditions: a. The conduit is terminated in listed fittings. b. For metric designators 12 through 16 (trade sizes 3/8 through ½), the circuit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less. c. For metric designators 21 through 35 (trade sizes ¾ through 1 1/4), the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes and there is no flexible metal conduit, flexible metallic tubing, or liquid-tight flexible metal conduit in metric designators 12 through 16 (trade sizes 3/8 through ½) in the effective ground-fault current path. d. The combined length of flexible metal conduit and flexible metallic tubing and liquid tight flexible metal conduit in the same effective ground-fault current path does not exceed 1.8 m (6 ft). e. If used to connect equipment where flexibility is necessary to minimize the transmission of vibration from equipment or to provide flexibility for equipment that requires movement after installation, a wire-type equipment grounding conductor shall be installed. (7) Flexible metallic tubing, with an individual equipment grounding conductor, where the tubing is terminated in listed fittings and meeting the following conditions. a. The circuit conductors contained in the tubing are protected by overcurrent devices rated at 20 amperes or less. b. The combined length of flexible metal conduit, flexible metallic tubing and liquid-tight flexible metal conduit in the same effective ground-fault current path does not exceed 1.8 m (6 ft).

(Ord. No. 4550, § 1(Res. No. 12506, § 1(Exh. A)), 9-20-22, eff. 1-1-23)

Ask a question about Scottsdale law

Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.