For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 25-2-657 — DOWNTOWN DENSITY BONUS 400 (DDB400) COMBINING DISTRICT AND DOWNTOWN DENSITY BONUS (DDB850) COMBINING DISTRICT REGULATIONS

Austin City Code (Supp. No. 174: codified through Ordinance No. 20260521-050, effective June 1, 2026) · Austin City Code § 25-2-657

Corpus is an independent public-information project, not the official City of Austin website. Stable reference: corpuslaw.us/code/e8801f70-8bae-4359-a7bd-1389e752fb86

§ 25-2-657 - DOWNTOWN DENSITY BONUS 400 (DDB400) COMBINING DISTRICT AND DOWNTOWN DENSITY BONUS (DDB850) COMBINING DISTRICT REGULATIONS.

(A) This section applies to a property with DDB400 zoning or DDB850 zoning. (B) Except as provided in (C) below, this section governs over a conflicting provision of this title or other ordinance. (C) If this section conflicts with the Pecan Street Overlay (PS) district, the more restrictive provision controls. (D) Pre-Requisites. (1) To use the regulations described throughout this section, the site's zoning must include DDB400 zoning or DDB850 zoning. (2) Unless otherwise identified, a development must comply with: (a) Affordability Requirements defined in this Section; (b) Gatekeeper Requirements defined in this Section; and (c) Urban Design Standards defined in this Section. (3) To preserve reserved dwelling units and existing non-residential spaces, an applicant must comply with Article 2 (Density Bonus and Incentive Programs), Division 1 (General Provisions) of Chapter 4-18 and, when applicable, Section 4-18-32(A)(2)—(5) (Existing Multi-Family Structure) before applying for a building permit or site plan that relies on the regulations described in this section. (4) In addition to pre-requisites and general regulations, a development must comply with any regulation specifically applicable to DDB400 zoning or DDB850 zoning. (E) Combining Districts. (1) DDB400 zoning and DDB850 zoning may only be combined with a site located within the boundary designated by Appendix H (DDB400 and DDB850 Boundaries). (2) DDB400 zoning and DDB850 zoning cannot be combined with: (a) a townhouse and condominium residence (SF-6) district or a more restrictive residential zoning district; (b) a vertical mixed use (VMU) overlay district, which is designated by as vertical mixed-use building (V); or (c) other density bonus (DB) combining districts, except that DDB400 zoning and DDB850 zoning may be combined with the density bonus ETOD (DBETOD) combining district. (3) A site's zoning cannot include both DDB400 zoning and DDB850 zoning. (F) Definitions. In this section, (1) AFFORDABILITY MINIMUM means the minimum percentage of owned or leased affordable units a development must provide or the minimum amount of fee-in-lieu that must be provided. (2) AFFORDABLE OWNERSHIP UNIT means a dwelling unit that is for sale and is reserved for an income-eligible household. (3) AFFORDABLE RENTAL UNIT means a dwelling unit that is for lease and is reserved for an income-eligible household. (4) AFFORDABLE UNIT means an affordable ownership unit or an affordable rental unit. (5) BONUS AREA means the gross floor area contained within the portion of a building or structure that exceeds the maximum buildable area, including maximum building height, allowed in the base zoning district, which is achievable with DDB400 zoning or DDB850 zoning. (6) COMMUNITY BENEFIT OPTION means a community benefit described in this section that is provided onsite to reduce the affordability minimum required to obtain bonus area. (7) DIRECTOR means director of Austin Planning. (8) FEE IN-LIEU means the dollar amount an applicant pays to the City's Affordable Housing Trust Fund per gross square foot of bonus area. (9) GATEKEEPER REQUIREMENTS means minimum development requirements not described as Affordability Requirements or Urban Design Standards required to obtain bonus area. (10) GREAT STREETS STREETSCAPE STANDARDS means design standards for streets within the boundaries of the Great Streets Master Plan. (11) MFI means the Austin-Round Rock Metropolitan Statistical Area Median Family Income as determined by the director of Austin Housing. (12) URBAN DESIGN STANDARDS means standards for buildings, site design features, public streetscapes, plazas, and other design elements provided in this section to comply with DDB400 zoning or DDB850 zoning. Urban design standards include standards which are mandatory and optional. (G) DDB400 zoning. (1) A building located on a site with DDB400 zoning may exceed the maximum building height in the base zoning district by a maximum of 400 feet except that no building may exceed 750 feet in height. (2) A site with DDB400 zoning seeking bonus area must provide mandatory urban design standards and six optional urban design standards described in Subsection (R) below. (H) DDB850 zoning. (1) A building located on a site with DDB850 zoning may exceed the maximum building height in the base zoning district by a maximum of 850 feet except that no building may exceed 1,200 feet in height. (2) A site with DDB850 zoning seeking bonus area must provide mandatory urban design standards and provide nine optional urban design standards described in Subsection (R) below. (I) Affordability Requirements. (1) To achieve bonus area or use a development standard for DDB400 zoning or DDB850 zoning that is not height-related, a development must provide the affordability minimum. (2) The affordability minimum is established as follows: (a) Pay fee-in-lieu equivalent to 100 percent of the bonus area. The amount of fee-in-lieu owed is set by separate ordinance and is determined using the fee schedule in effect at the time of site plan submittal; or (b) Provide affordable units equal to five percent of onsite residential units as: (i) affordable rental units at 50 percent MFI; or (ii) affordable ownership units at 80 percent MFI; (3) To utilize the onsite affordability option, a building seeking bonus area must be designed for: (a) multifamily residential use only, or (b) a minimum of 65 percent of gross square footage shall include multifamily use if the building contains a mix of uses. (4) If a community benefit option is provided onsite, the affordable minimum may be reduced by a total of two percent of the onsite units or reduced by a total of 20 percent of the fee-in-lieu. (J) Gatekeeper Requirements. A development must demonstrate compliance with the following requirements at the time of site plan, (1) To receive bonus area, the development must demonstrate the minimum number of Urban Design Standards elements required for DDB400 zoning or DDB850 zoning. (2) Great Street Standards. (a) Except as provided in Subdivision (2)(b), to receive bonus area, the development must demonstrate compliance with streetscape improvements along all public street frontages, consistent with the Great Streets Standards. (b) To receive bonus area, for a property located on a Texas Department of Transportation frontage, an applicant satisfies paragraph (2) requiring Great Streets streetscape improvements along all public street frontages if the applicant pays a fee in-lieu set by separate ordinance and a one-time maintenance obligation fee set by separate ordinance. The director of the Transportation and Public Works Department may spend a fee paid under this subsection for Great Streets capital improvement projects within the area identified in Appendix H (DDB400 and DDB850 Boundaries). (3) To receive bonus area, each building located on a site with DDB400 zoning or DDB850 zoning shall demonstrate compliance with the Austin Energy Green Building program's latest applicable Bird Collision Deterrence criteria and shall achieve a two-star or greater rating using the applicable rating version in effect at the time a rating registration application is submitted for the building. (K) Community Benefits Options. (1) Onsite Grocery Store: (a) In this subsection, FOOD SERVICE means a use described in Chapter 25-2 (Zoning) that allows a grocery store occupancy. (b) A development must be designed and contain a minimum food sales use of 2,500 square feet. (2) Onsite Cultural Services or Performance Venue: (a) In this subsection, CREATIVE SPACE means a use described in Chapter 25-2 (Zoning) that allows cultural services or performance venue occupancy. (b) A development must be designed and contain a minimum creative space use of 2,500 square feet. (3) Austin Energy Green Building: All residential and commercial development shall achieve a minimum three-star rating or greater rating under the Austin Energy Green Building program using the applicable rating version in effect at the time a rating registration applicable is submitted for the building. (4) Transit Supportive Infrastructure. (a) In this section, TRANSIT SUPPORTIVE INFRASTRUCTURE includes appurtenances, facilities, and amenities related to a transit system project as defined in Ordinance No. 20221115-048. (b) An applicant must submit a written request to the Project Connect Mobility Officer to provide transit supportive infrastructure. (c) If the applicant proposes transit supportive infrastructure that serves a community benefit, the Project Connect mobility officer is required to approve a request. (d) Before approving a request to provide transit supportive infrastructure, the director of Project Connect mobility officer will adopt rules under Chapter 1-2 (Administrative Rules) that establish when transit supportive infrastructure serves a community benefit. (L) Permitted and Conditional Uses. (1) The following uses are permitted on a property utilizing DDB400 or DDB850: (a) residential uses; (b) a local use as defined in this Subsection; and (c) unless specifically prohibited or made conditional in this Subsection, uses permitted by the zoning that applies to the property. (2) The following uses are prohibited on a property utilizing DDB400 or DDB850: COMMERCIAL USES: | Recreational Equipment Sales Agricultural Sale and Services | Research Assembly Services Automotive Sales | Research Testing Services Automotive Rentals | Research Warehousing Services Automotive Repair Services | Scrap and Salvage Building Maintenance Services | Service Station Campground | Stables Carriage Stable | Vehicle Storage Convenience Storage | INDUSTRIAL USES: Drop-off Recycling Collection Facility | Basic Industry Electronic Prototype Assembly | General Warehousing and Distribution Electronic Testing | Recycling Center Equipment Repair Services | Resource Extraction Equipment Sales | AGRICULTURAL USES: Exterminating Services | Animal Production Funeral Services | Crop Production Marina | Indoor Crop Production Recreational Equipment Maintenance & Storage (3) A conditional use under the base zoning district that applies to the property remains a conditional use on a property utilizing DDB400 or DDB850. (4) The following uses are additional conditional uses of a property utilizing DDB400 or DDB850: COMMERCIAL USES: | Off-Site Accessory Parking Alternative Financial Services | Pawn Shop Services Automotive Washing | Pedicab Storage and Dispatch Bail Bond Services | Special Use Historic Commercial Blood Plasma Center | INDUSTRIAL USES: Commercial Off-Street Parking | Custom Manufacturing Communications Services | Light Manufacturing Construction Sales and Services | Limited Warehousing and Distribution Electric Vehicle Charging Kennels | AGRICULTURAL USES: Monument Retail Sales | Horticulture (5) The following uses are local uses on a property utilizing DDB400 and DDB850: Administrative and Business Offices | Retail Sales (convenience or general) Art Gallery | Indoor Sports and Recreation Art Workshop | Medical Offices (not exceeding 5,000 square feet gross floor area) Business and Trade School | Performance Venue Consumer Convenience Services | Personal Improvement Services Consumer Repair Services | Personal services Counseling Services | Pet Services Custom Manufacturing | Postal Services Cultural Services | Printing and Publishing Services Child Care Services (general or limited) | Professional Office Adult Care Service (general or limited) | Restaurant (general or limited) Financial Services | Restaurant (general or limited) as an accessory use Food Preparation, in conjunction with Food Sales, | Theater Food Sales | A use which a conditional use site plan has been approved by the Land Use Commission Guidance Services (M) Mandatory Urban Design Standards (UDS). (1) UDS-1 (Screening) (a) Utility equipment, mechanical equipment, solid waste collection areas including loading docks, truck parking, outdoor storage, trash collection, trash compaction and other service functions: (i) are prohibited in the area between a building and a street; (ii) must not be visible from a street, adjacent property line, and the property line on the far side of an adjacent public street; (iii) must be screened or located in a public alley; and (iv) screening materials shall be the same as, or of equal quality to, material used for the principal building. (b) This subsection applies to a site with frontage on an alley 20 feet or more wide. (i) A transformer room or utility vault must be located adjacent to and accessible from the alley unless an alternative location is required by Austin Energy. (ii) A pump room, sprinkler room, or other utility or mechanical room must be adjacent to and accessible from the alley unless an alternative location is required by the Austin Fire Department. (c) Above-ground parking structures must be screened to prevent spaces from view of a public street and adjacent properties. (2) UDS-2 (Parking). (a) A development must comply with Subsection (F) of Section 25-6-591 (Parking Provision for Development in the Central Business District (CBD), the Downtown Mixed Use (DMU) District, the Public (P) Zoning Districts, and the University Neighborhood Overlay (UNO) District) except that the number of motor vehicle parking spaces allowed is restricted to 60 percent of the number of spaces previously required by Appendix A (Tables of Off-Street Parking and Loading Requirements) of Chapter 25-6 (Transportation), or (b) A development must comply as follows: (i) A development of less than 10,000 square feet gross floor area or containing less than 71 residential units may include a maximum of 60 percent of spaces previously required by Appendix A (Tables of Off-Street Parking and Loading Requirements) of Chapter 25-6 (Transportation), or (ii) A development not described in (b)(i) above is limited to 60 percent of spaces previously required by Appendix A - (Tables of Off-Street Loading Requirements and Former Off-Street Parking Requirements) of Chapter 25-6 (Transportation) unless: A. all spaces are provided within a parking structure; or B. all spaces exceeding the 60 percent limitation described in subsection (b)(i) above are provided within an underground parking structure. (3) UDS-3 (Pedestrian-Oriented Frontage Requirements) (a) In this section, PRINCIPAL STREET has the same meaning assigned in Article 5 (Definitions) of Subchapter E. (b) At least 75 percent of the ground floor building frontage along the principal street must contain one or more commercial or civic uses and must comply with the dimensional requirements found in Section 4.3.3.C in Subchapter E (Design Standards and Mixed Use) of this chapter. (c) For properties with less than 100 feet along the frontage of the principal street, 50 percent of the ground floor occupiable area must contain one or more commercial or civic uses and must comply with the dimensional requirements found in Section 4.3.3.C in Subchapter E (Design Standards and Mixed Use) of this chapter. (d) Lobbies may qualify as pedestrian-oriented commercial or civic spaces if they include seating, are visible from the street, and are publicly accessible. A lobby not meeting these qualifications may only count up to 10 percent towards the required pedestrian-oriented commercial or civic space if the lobby serves only residential or office uses, is visible from the sidewalk, and has direct street access. (4) UDS-4 (Primary Entrance Requirements). (a) In this section, an ENTRANCE shall include a primary retail or residential lobby building entry point with direct street access or shared public access. (b) Excluding alleys, buildings with: (i) at least 150 feet of a single street frontage shall provide at least one entrance on that frontage, and (ii) over 200 feet of single street frontage shall provide an entrance per every 150 feet of frontage, with a minimum of two entrances. (c) When not in conflict with Great Streets, all buildings must provide permanent overhead shelter over all required entrances, with a shelter depth of no less than 40 percent of the clear height. (5) UDS-5 (Limit Curb Cuts). (a) A development shall minimize curb cuts shall be located to preserve continuous active frontage. (b) Unless required by Austin Fire or Austin Transportation and Public Works, vehicular access from a site to a public street shall be limited to: (i) one curb but for each 140 feet of single street frontage along a street that runs east and west; and (ii) one curb cut along a street that runs north and south. (R) Optional Urban Design Standards (UDS). (1) UDS-6 (Enhanced Pedestrian-Oriented Frontage Requirements). (a) A minimum of 75 percent of the total building frontage on the ground floor of must contain one or more commercial or civic uses and must comply with the dimensional requirements found in Section 4.3.3.C in Subchapter E (Design Standards and Mixed Use) of this chapter; and (b) In alignment with Great Streets Streetscape Standards provide a street-facing outdoor amenity space which must: (i) be located within 3 feet of an adjacent sidewalk grade; (ii) be a minimum size equal to a ratio of 250 square feet for every 100 feet of street frontage, but in no event smaller than 10 feet by 10 feet space; (iii) be located adjacent to a public right-of-way; (iv) be directly accessible from the sidewalk or other public access; and (v) remain unobstructed by fencing, barriers, and walls which exceed 36 inches in height. (2) USD-7 (Enhanced Primary Entrance Requirements). (a) In this section, an ENTRANCE shall include a primary retail or residential lobby building entry point with direct street access or shared public access which satisfies pedestrian activation standards. (b) Excluding alleys, buildings with: (i) at least 150 feet of a single street frontage shall provide at least two entrances on that frontage, and (ii) over 200 feet of single street frontage shall provide an entrance per every 75 feet of frontage, with a minimum of three entrances. (c) When not in conflict with Great Streets, all buildings must provide permanent overhead shelter over all required entrances, with a shelter depth of no less than 40 percent of the clear height. (3) UDS-8 (Bicycle Parking). A development must provide the greater of: (a) an additional 15 spaces beyond the minimum spaces required in compliance with Section 25-6-477 (Bicycle Parking), or (b) spaces equal to 15 percent of the proposed motor vehicle parking spaces. (4) UDS-9 (Limit Garage Lanes) A driveway shall not exceed a two-lane width when accessing a public street from a parking garage. (5) UDS-10 (Minimum Cantilever Clearance). A cantilever building shall maintain 40 feet of clearance from ground when located next to the public right of way to allow trees to grow. (6) UDS-11 (Enhanced Pedestrian Protection). (a) When Great Streets Streetscape Standards allows, a development shall provide permanent sheltering structure abutting the pedestrian clear zone along a minimum of 60 percent of the street frontage, including parking garage entrances and exits, with a depth of no less than 40 percent of the clear height. (b) Sheltering structures, including overhangs, canopies, awnings, and arcades, must not exceed a height of 14 feet. (7) UDS-12 (Increased Transparency Façade on Street-Facing Ground Floor). (a) All ground floor external doors and windows must maintain a minimal visible light transmittance of 60 percent and an external reflectance of 20 percent. (b) Materials used to satisfy (a) above must adhere to the Bird Friendly Design Standards outlined in the Austin Green Energy Building Standards. (8) UDS-13 (Above Ground Floor Transparency). (a) All external windows on the two floors immediately preceding the ground floor must maintain a minimal visible light transmittance of 60 percent and an external reflectance of 20 percent. (b) Materials used to satisfy (a) above must adhere to the Bird Friendly Design Standards outlined in the Austin Green Energy Building Standards. (9) UDS-14 (Additional Amenities). A building must include on the floor used for primary access to the public right-of-way, or provide outside of the building and immediately adjacent to the public right-of-way, one of the following: (a) a full bathroom facility complying with the Americans with Disabilities Act (ADA) standards for accessible design; (b) a room complying with the ADA design standards for use as a dressing, fitting, or locker room, containing a compliant baby changing station and a sink or hand washing station; or (c) a drinking fountain complying with ADA design standards. (10) UDS-15 (Planting Area or Green Roof). (a) A minimum of 15 percent of gross site area must be used as an at- grade planting area; or (b) A minimum of 50 percent of a building or structure must satisfy the requirements of the Vegetated ("Green") Roof Performance Standards in Appendix W of the Environmental Criteria Manual. The percentage of vegetated roof cover is calculated as a portion of total roof area excluding mechanical equipment, photovoltaic panels, swimming pools, and skylights. (11) UDS-16 (Historic Building Scale Matching) For development on a site located adjacent to a property that is currently zoned with a historic landmark (H) combining district or included within a historic district (HD) combining district (historic building), or is a contributing structure to an HD district (contributing structure): (a) the height of a building or structure is limited to not more than 15 feet above the height of the front façade of an adjacent historic building or contributing structure located within 15 feet, unless the conditions in (b) of this subsection are satisfied. (b) the height of a building or structure may exceed the 15 foot limitation in (a) of this subsection, if a minimum 15 foot stepback is provided as measured from the base height calculation of the building or structure. Base height calculation is the building height limit described in (a) of this subsection. (12) UDS-17 (Preserve Existing Building Façade). For development on a site without a historic landmark (H) combining district or not included within a historic district (HD) combining district: (a) must preserve the primary façade (typically being the front facing wall) of a building or structure that has existed for at least 45 years or longer at the time of site plan; and (b) the height of a building or structure which exceeds the preserved façade described in (a) of this subsection, must provide and maintain a minimum 10 foot stepback as measured from the preserved façade. (S) Development Standards. (1) Multifamily Residential Use. (a) A minimum of two percent of the total number of dwelling units must be accessible to a person with a hearing or visual disability. (b) A minimum of 10 percent of the total number of dwelling units must be accessible to a person with a mobility impairment. (c) Each ground floor dwelling unit must be adaptable for use by a person with a disability and accessible by a person with a disability from the on-site parking, pedestrian path, and common area building facilities. (2) Setbacks. (a) Except as provided in this subsection, there are no minimum front yard or street side yard setbacks. (b) The maximum front yard and street side yard setbacks are 10 feet, except for a public plaza or private common open space. (c) There are no minimum or maximum interior side yard setback. (d) There are no minimum or maximum rear yard setback. (e) If the width of the right-of-way is less than 60 feet, the minimum front yard setback for a building with three or more stories in height shall be 30 feet as measured from the centerline of the street. (3) A site is not required to comply with the base zoning district's: (a) minimum site area requirements (if applicable); (b) maximum floor area ratio; (c) maximum building coverage; (d) Article 9 (Landscaping), (e) Private Common Open Space requirements in Subchapter E (Design Standards and Mixed Use).

Source: Ord. No. 20260528-067, Pt. 8, 6-8-26.

Ask a question about Austin law

Corpus searches the Austin sections it holds and shows the ones that match, with their citations. Free, no sign-in.