§ 10-13 — Key box
Greensboro Code of Ordinances (Supp. No. 133, Update 1: codified through ordinances of June 16, 2026) · Greensboro Code of Ordinances § 10-13
Corpus is an independent public-information project, not the official City of Greensboro website. Stable reference: corpuslaw.us/code/e9c1110d-f507-436d-aeec-39bb2f157351
Sec. 10-13. - Key box.
A key box shall be installed on all new construction where a fire alarm system and/or a sprinkler system has been installed, on existing construction where nuisance or repeated alarms occur, on access gates where access is delayed and on any other occupancy where the fire official deems necessary access is delayed or a delay occurs when returning fire apparatus back to service. (1) [Accessibility.] The fire official shall require a key box to be installed in an accessible location where immediate access is necessary to verify the existence of a fire or other emergency in buildings equipped or required to be equipped with fire detection or fire suppression systems or equipment. (2) Where required. Other than one- and two-family dwellings, all new occupancies served by an internal automatic fire detection or suppression system, having a connection to a central monitoring station facility or other recognized NFPA 72 monitoring method, on all new and existing occupancies on gates where controlled access can delay fire department vehicle response, on all existing facilities where frequent or nuisance fire alarms occur, and on all other agreed upon locations. (3) [Specifications for] key boxes. Approved locks shall be Medico Biaxel level 7 or equivalent and UL 437 listed for "safety key locks". Key vaults shall be listed under UL 1610 standard for central station alarm units for use with UL listed alarm systems, shall be UL listed under UL 1037 standard for antitheft alarms and devices, and shall have a minimum wall thickness of one-fourth (¼) inch and door thickness of one-half (½) inch plate steel. Fully inserted key shall be able to withstand a minimum of fifty (50) inch pounds torque. Key vaults shall have a weatherproof gasket seal neoprene material or equivalent, and shall be master-keyed. Lock code and key section shall be unconditionally restricted by the key vault manufacturer for use only by the local assigned fire department. All fire department vehicles containing keys shall be recorded and inventoried annually. Lock code restriction shall be traceable to the lock manufacturer and be guaranteed by both the lock manufacturer and the key vault manufacturer. The local fire department shall be in complete control of the rapid key entry system authorization and operation. Entry systems shall utilize approval signatures from the local fire department for release of keys and all lock products from the factory. (4) Installation location. The key box shall be located on the exterior of a structure, at or near the main entrance, at an entrance adjacent to the sprinkler riser where one is present, or at another location where approved by the fire official. Key box shall be installed no less than four (4) feet and no more than six (6) feet above entrance grade and shall be horizontally within five (5) feet of the opening. (5) Key vault contents. The vault shall contain keys for the following: a. Main entrance door (mixed occupancy and strip shopping center keys shall be provided for occupancies where system control valves or fire alarm panels exist). b. Alarm rooms. c. Mechanical/sprinkler control rooms. d. Fire alarm control panel. e. Special keys to reset fire alarm initiating devices. f. Special rooms where specific fire suppression systems reside. g. Gate access boxes for use in case of power failure. The owner shall be responsible for providing all up to date keys in the vault at all times. (6) Administration. a. New occupancies. The plan review section shall be responsible for the administration of the program on all new occupancies. b. Existing occupancies. The inspections division, with the assistance of the suppression division, shall be responsible for identifying existing problem occupancies and other agreed upon situations. The plan review section will provide all start up documentation and maintain a current inventory control list. (7) Compliance. All new construction shall be required to complete the installation of the key boxes per the manufacturers installation requirements prior to the issuance of a final certificate of occupancy. All existing structures, gates, etc., shall have up to six (6) months to install such key boxes. Upon expiration of inspection compliance procedures, property owners shall face existing reinspection fee procedures and other citations for noncompliance.
(Ord. No. 22-141, § 1, 6-21-22)
Ask a question about Greensboro law
Corpus searches the Greensboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.