§ 8.80.140 — Noise measurement procedure
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 8.80.140
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/ea057e99-256a-42c9-91fe-ed5d505aca1e
8.80.140 - Noise measurement procedure.
The measurement procedure presented in this Section assumes that personnel performing the noise measurements have been trained in the use of the instruments and in interpretation of measured data. Upon receipt of a complaint from a citizen, the Noise Control Officer, or his agent, equipped with sound level measurement equipment satisfying the requirements specified in Section 8.80.020, shall investigate the complaint. The investigation shall consist of a measurement and the gathering of data to adequately define the noise problem as specified in the California Office of Noise Control Model Enforcement Manual, and shall include the following: A. Nonacoustic Data. 1. Type of noise source; 2. Location of noise source relative to complainant's property; 3. Time period during which noise source is considered by complainant to be intrusive; 4. Total duration of noise produced by noise source; 5. Date and time of noise measurement survey. B. Procedure. Utilizing the A weighting scale of the sound level meter and the slow meter response, the noise level shall be measured at a position or positions along the complainant's property line closest to the noise source or at the location along the boundary line where the noise level is at a maximum. In general, the microphone shall be located five feet (5') above the ground; ten feet (10') or more from the nearest reflective surface, where possible. However, in those cases where another elevation is deemed appropriate, the latter shall be utilized. If the noise complaint is related to interior noise levels, interior noise measurements shall be made at a point at least four feet (4') from the wall, ceiling or floor nearest the noise source with windows in the normal seasonal configuration. Calibration of the instrument being used shall be performed immediately prior to and following the recording of any noise data utilizing the acoustic calibrator.
(Ord. C-5371 § 1 (part), 1977: prior code § 4430.5)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.
