For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2-74 — MU-R (Mixed-Use Redevelopment and Small Lot) district

Code of Ordinances, City of Round Rock, Texas (Supp. 27: codified through Ordinance of August 13, 2026 (online updated November 5, 2026)) · Round Rock Zoning and Development Code, art. VI, § 2-74

Corpus is an independent public-information project, not the official City of Round Rock website. Stable reference: corpuslaw.us/code/ea2b6ba0-3773-4aa7-98f3-4a2ca8516b50

Sec. 2-74. - MU-R (Mixed-Use Redevelopment and Small Lot) district.

(a) Purpose. (1) To allow for the development of small lots where the desired development or redevelopment cannot be accommodated with existing commercial district standards. This district also permits mixed-uses, including a residential component that typically would not otherwise be accommodated. The development standards establish projects with a more pedestrian-oriented and urban scale. (2) The standards herein are not intended to be of a particular style or period, but to encourage high-quality construction and development that fits the proportions and functional characteristics of a mixed-use district with an urban and pedestrian-oriented feel. (b) Permitted uses. Uses permitted in the MU-R district may be found in Sec. 2-77, with the following supplementary note: (1) In order for a restaurant/bar with an outdoor cooking area to qualify for a special exception, no outdoor cooking areas shall be permitted to share a common lot line with an existing single-family use. (c) Lot and building dimensional standards. Property and buildings in the MU-R district shall conform to the standards found in Sec. 2-78, with the following supplementary notes: (1) Special purpose lots, such as landscape lots and utility lots, are exempted from these requirements. (2) A contextual setback may be considered when the frontage within a block is occupied or partially occupied by a building or buildings with front yards of greater depth than 10 feet. The zoning administrator shall consider roadway type, development patterns, and adopted land use plans for the block on which the project is located in determining a modification to this setback. (3) Side wall requirements for separation from adjacent structures, wall construction, and allowable openings for elements such as windows and doors shall be regulated by the Fire Code. (4) Number of stories includes mezzanines or other occupiable levels. Rooftop decks and patios shall not be included in the number of stories, but structures placed on rooftop decks and patios shall qualify towards the height requirement. The height of the structure abutting an existing single-family residential use is limited to the height of the single-family structure's nearest wall excluding the roof and attic plus one foot in height from every foot of distance from the existing single-family residential use. (5) Fences may be eight (8) feet in height to accommodate topographical changes, as approved by the Zoning Administrator. (d) Supplementary development standards. In addition to the applicable standards found in Chapter 8 of this Code, the following regulations apply to the MU-R district: (1) Parking. On-site parking shall be placed in an unobtrusive location that minimizes impacts to pedestrian circulation. a. On-site parking. 1. Due to the variable nature of lot sizes and use, a parking generation study shall be provided with each development application for all nonresidential uses. The parking generation study shall include the following criteria: i. A demand analysis of parking need based on industry standards. ii. Characteristics of those using parking, including turnover rate. 2. On-site parking shall be required for all residential uses, or residential portions of any building. i. Required residential parking per unit: 1 Bedroom: 1 space 2 Bedrooms or more: 2 spaces ii. For residential units without defined bedrooms: Under 800 square feet: 1 space 800 square feet or more: 2 spaces iii. Tandem parking shall be permitted to accommodate the residential parking requirement. 3. Alternative solutions may include a shared parking agreement as described in Sec. 8-47 or other solution as approved by the Public Works Director. b. All parking shall be constructed in accordance with the following requirements in addition to standards provided in chapter 8, article VI of this Code: 1. Parking and access shall be permitted only on improved surfaces. 2. Vehicular entrances to all parking areas shall be no wider than the minimum standard allowed by the Design and Construction Standards. 3. On-site parking areas are prohibited in any street yard, and all parking shall be setback a minimum of five (5) feet from any street-facing building façade. For the purposes of through lots, the street yard shall be designated as that which fronts on the roadway with the higher classification. 4. All existing driveways that are no longer required for parking access shall be removed and replaced with landscaping at the time of site plan review and street improvements installed to match adjacent areas. 5. On-site parking areas visible from a public street shall be screened by a building or wall, hedge or other landscaping screen that is at least three (3) feet in height. c. On-street parking. 1. The applicant for a building permit may provide on-street parking adjacent to the property, if the existing right-of-way will accommodate it. The materials, design and location of the parking improvements shall be approved by the City. d. Structured parking. All structured parking garages where any of the parking is above grade shall meet the following standards, in addition to the standards in subsection (c) above: 1. The first 20 feet in height of the frontage of a garage that faces a public street, except for pedestrian and vehicular ingress and egress areas, shall require either a ground-level use or vehicle parking areas to be screened from view from a public street by means of landscaping or manufactured materials. 2. Exterior garage building materials shall be limited to natural stone, simulated stone, brick, split-face or stone-face concrete masonry units (CMU), or architecturally finished steel or metal. 3. The glazing percentage requirements provided in subsection (e)(7) shall apply to ground-level occupant spaces, if any. 4. Pedestrian access. i. Pedestrian ingress and egress to all parking structures shall provide access directly to a street or public frontage except for underground parking levels, where pedestrians may exit the parking area directly into a building. ii. Pedestrians shall have direct access from parking areas to the street on the primary frontage. iii. There shall be direct access to the street from commercial uses. 5. Service access shall be from the rear or a secondary frontage where one exists and shall be enclosed or screened from view. (2) Traffic impact analysis. A Traffic Impact Analysis (TIA), deferral, or waiver shall be required for any development in the MU-R district prior to any site plan approval. (3) Access and circulation. a. Vehicle access and circulation standards provided in Sec. 8-60 apply to all new development. These include requirements for connections to existing and future roads, connection to adjacent development, and design requirements for driveways. b. Drive-throughs shall be prohibited except on lots fronting arterials, as defined by the Transportation Master Plan. The following conditions shall apply to any site where a drive-through is incorporated: 1. Only one (1) business on a site shall have a drive-through. 2. Drive-throughs shall be part of a building containing two (2) or more occupants or uses. 3. The principal use associated with the drive-through shall not occupy more than 50% of the gross floor area of a single-story building. For multi-story buildings, the principal use may occupy the entire first floor. 4. Off-street vehicle stacking spaces are prohibited in any front street yard and shall meet the stacking area standards and design provided in Sec. 8-52. 5. Vehicular entrances and exits shall be no wider than the minimum required for one (1) vehicle and shall be in accordance with the Design and Construction Standards. (4) Lot fencing design standards. a. The following standards apply to all lot fencing in the MU-R district, in addition to the applicable standards found in Sec. 8-35: 1. Fences shall be constructed of brick, natural stone, simulated stone, or shall be view fencing. Other decorative masonry materials, reinforced concrete, or view fencing equivalents may be approved by the Zoning Administrator. 2. Fence posts shall be constructed of rust-resistant metal parts, concrete-based masonry or concrete pillars of sound structural integrity. 3. Fence posts and fence panels shall be capped. 4. All fences shall provide a finished face to abutting single-family or townhouse uses. 5. All fences shall provide a finished face to abutting streets. b. Except when view fencing is required by Section 8-65, all nonresidential uses shall be required to install and maintain a fence constructed of masonry materials such as brick, natural stone, simulated stone, decorative reinforced concrete, or other equivalent material approved by the zoning administrator, a minimum of six feet in height, along every property line which is shared with a SF or TF use and is not in the street yard. The zoning administrator may waive the requirement based upon a finding of any of the following: 1. The zoning administrator determines that due to the site plan layout and/or existing site conditions, potential impacts will be negligible; 2. The zoning administrator receives a letter from the adjacent residential property owner(s) requesting that the fence not be installed; or 3. The zoning administrator determines that existing and/or proposed vegetation will serve as an adequate screen. (5) Landscaping. a. Where the building setback provides adequate space, landscaping foundation treatment shall be required in accordance with the Category 3 standards in Sec. 8-10. b. Minor modifications to design and development standards may be permitted to protect and accommodate protected trees as identified in chapter 8, article III. c. Screening for parking shall be in accordance with subsection (d)(1)b.5. above. d. Pervious concrete and pervious pavers for parking and maneuvering areas are permitted. Other permeable surfaces may be approved by the Zoning Administrator. (6) Outdoor storage and display. a. General outdoor storage is prohibited. b. Outdoor display and limited outdoor storage shall be allowed in accordance with Sec. 8-65. c. Limited outdoor storage is prohibited in the street yard. (7) Site furniture. a. Site furniture for nonresidential uses, as defined in Sec. 1-50, shall be required to be of a commercial grade and manufactured for exterior use. b. Site furniture may also include moveable outdoor site features such as outdoor café tables and planters. (8) Special conditions for public open space including parks, trails, creeks, and public plazas. a. No opaque fences shall be allowed on the portion of a lot abutting any public open space. Wrought iron fencing or equivalent may be used. b. There shall be no loading or service areas between the buildings and public open spaces. c. An eight (8) foot wide linear landscaped area in accordance with Sec. 8-10(g)(3) shall be required on lots abutting public open space that have their parking between the buildings and the public open space. If site constraints inhibit the incorporation of the required landscaped area, alternative landscaping may be approved by the Zoning Administrator. (e) MU-R district design standards. The following design standards apply to all buildings in the MU-R district, except for certain expansions, as addressed in subsection (g). Additional standards for expansions and conversions are provided in subsections (f) and (g) below and replace their counterparts in this subsection where applicable. Alternate design standards may be approved by the zoning administrator to permit a more flexible or creative design that still meets the intent of the MU-R district design standards. (1) Exterior wall finish. The exterior finish of all buildings shall be natural stone, simulated stone, brick, architectural concrete masonry units (CMU), glass, stucco, fiber cement siding (excluding flat, unarticulated panels), or architecturally finished steel or metal, except for doors, windows, accents and trim. a. Fiber cement siding shall not comprise more than 33 percent of the exterior wall finish. b. If architectural CMU is incorporated into a project, it shall have an ashlar pattern. c. The use of materials such as wood shingles and wood siding shall be limited to accent features. d. Other wall materials or recognized architectural styles not explicitly permitted by this section may be approved in writing by the Zoning Administrator. (2) Orientation requirements. a. Main entrances shall be visible to pedestrians from the street or a public plaza on the primary frontage. b. Buildings with multiple street frontages shall be designed with primary facades facing each public street. c. Where ramps or other accessibility-related structures are installed, they shall be integrated into the building design by facing the structure with the same exterior materials as the building, using the same stone material that was used in the landscape if applicable, or screening structures behind planters and other landscape features. (3) Exterior color. Day-Glo, luminescent, neon, or similar types of color finishes are prohibited. (4) Building elevation variation. a. The length of walls facing public streets shall be broken into smaller planes. Wall planes shall not extend more than an average of 50 feet without an offset or interruption by a pilaster or structural frames, change in roof line or architectural materials. b. For buildings with a primary façade length of greater than 100 feet, offsets of at least three (3) feet in depth shall be required for every 50 feet of façade length. c. The composition of windows and other major features shall relate to the wall plane between each offset or other feature identified in subsection (e)(4)b, immediately above. (5) Building articulation. a. All buildings shall be designed to include varied relief to provide interest and variety and to avoid monotony. This shall include details that create shade and cast shadows to provide visual relief to the buildings. Horizontal and vertical elements of exterior walls should vary in height, design and projection to provide architectural interest and style. b. The following is a list of design features that may be used as part of an integrated, comprehensive building design to provide architectural interest and style. Such interest and style shall include a minimum of five (5) of the following: 1. Decorative cornices. 2. Eaves. 3. Bow window. 4. Bay window. 5. Arched window. 6. Gable window. 7. Transom windows. 8. Multiple sashed and/or paned upper story windows. 9. Oval or round windows. 10. Shutters. 11. Arched entry, balcony or breezeway entrance. 12. Recessed entryways. 13. Storefront (for retail uses). 14. Arcade/Gallery (for retail uses). 15. Stone or brick accent wall. 16. Decorative stone or brick band. 17. Decorative tile. 18. Veranda, porch or balcony. 19. Projected wall or dormer. 20. Variation of roof lines on the building. 21. Decorative caps and chimneys. 22. Stone coursing around windows. 23. Metal canopies. 24. Fabric awnings that relate to window and door bays. 25. Other features as approved by the zoning administrator. (6) Special design features for buildings with a setback greater than zero feet. The following is a list of special design features that shall be used as part of an integrated, comprehensive building and site design to provide architectural interest and style. Such interest and style shall include a minimum of at least one (1) of the following: a. Stoops, b. Rooftop decks, c. Courtyard, d. Forecourt, e. Structural landscape elements or public art that are installed within the setback. (7) Windows. In order to ensure appropriate proportion, shape, position, location, pattern and size of windows on a building, the following shall be required: a. The ground floor of the primary façade shall have a minimum of 40 percent glazing. All glazing on the primary façade of the ground floor shall have a light transmittance of 70 percent. b. Upper floors of the primary façade shall have a minimum of 30 percent glazing. c. At least 25 percent of the wall area on any side or rear elevation facing a park or plaza shall consist of glazing or as permitted by the Building Code, whichever is less. d. To assist with energy efficiency and solar gain the requirements in this subsection may be reduced by the Zoning Administrator to the extent that the required level or location of glazing conflicts with the standards of the Building Code or a recognized green building program. (8) Glass. Except for photovoltaic cells, mirrored glass with a reflectivity of 20 percent or more is prohibited on the exterior walls and roofs of buildings and structures. (9) Roofing Materials. a. Roofing materials for pitched roofs shall consist of a minimum 25-year architectural dimensional shingles, tile (clay, cement, natural or simulated stone), non-reflective prefinished metal, copper or other similar materials as approved by the Zoning Administrator. Portions of the roof screened by pitched roof sections shall be permitted to be flat to provide for mechanical equipment wells or roof decks provided all pitched sections of the roof meet the roofing material requirements. b. All roof-mounted mechanical equipment shall be screened from public view so as to not be visible from an abutting street, public plaza or public open space. The screen shall utilize the same or similar materials as the principal structure. (10) Awnings and Canopies. Awnings and canopies attached to buildings shall meet the following standards: a. Awnings and canopies shall be placed so as to avoid obscuring details of the building façade. b. Awnings and canopies shall be placed so that there is a minimum clearance of eight (8) feet at its lowest point when over a sidewalk or other pedestrian walkway. c. Awnings and canopies may encroach up to 10 feet or 66 percent of the distance from the building face to the curb, whichever is less. (f) Expansions. (1) Expansions to existing structures shall meet the height and setback standards established in subsection (c) or the contextual setback as defined in Sec. 2-96. (2) Expansions that are less than 35 percent of the existing gross floor area shall meet the following criteria: a. Expansions shall reflect the architectural style of the original building, including roof, articulation, windows, doors, and exterior finish. If the existing style is not desired for the expanded portion of the structure, the expansion shall meet the design standards provided in subsection (e), as applicable. b. Newly constructed portions of the building shall meet all development standards in subsection (d), as applicable. (3) The cumulative expansion of 35 percent or more of the gross floor area over any five (5) year period shall meet the following standards: a. Each street-facing façade shall be required to incorporate a minimum of three (3) improvements in accordance with subsection (e). b. Newly constructed portions of the building shall meet all development standards in subsection (d), as applicable. (g) Conversions. (1) Conversions in the MU-R District from single-family residential to a nonresidential use shall meet the following development standards in subsection (d): a. Parking (subsection (d)(1)); b. Traffic impact analysis (subsection (d)(2)); c. Access and circulation (subsection (d)(3)); d. Fencing design standards (subsection (d)(4)); e. Landscaping (subsection (d)(5)); f. Outdoor display and storage (subsection (d)(6)); g. Site furniture (subsection (d)(7)); and h. Special conditions for public open space (subsection (d)(8)). The following requirements from the district design standards (subsection (e)) may apply when changes to the exterior of a building are being made to a conversion: a. Exterior wall finish (subsection (e)(1)); b. Orientation requirements (subsections (e)(2)a. and (e)(2)c.); c. Exterior color (subsection (e)(3)); d. Roofing (subsection (e)(9)); and e. Awnings and canopies (subsection (e)(10)). (2) Expansions in the gross floor area during the conversion process shall meet the standards in subsection (e) above, as applicable.

(Ord. No. O-2020-0158, § VIII, 6-11-2020; Ord. No. O-2024-266, § XXV, 9-26-2024; Ord. No. O-2026-119, § IV, 5-14-2026; Ord. No. O-2026-220, § XI, 8-13-2026)

Ask a question about Round Rock law

Corpus searches the Round Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.