§ 35-1905 — Industrial design standards
Code of the City of Chandler (Supp. No. 80: codified through Ordinance No. 5171, adopted July 13, 2026) · Chandler City Code § 35-1905
Corpus is an independent public-information project, not the official City of Chandler website. Stable reference: corpuslaw.us/code/ea54711b-3266-4db6-b14f-66450cb6655d
35-1905. - Industrial design standards.
(1) Applicability: (a) The following objective design standards shall be applied to all new industrial uses, developed individually or as part of a larger industrial project. (b) These standards are intended to provide a clear set of architectural and site design requirements for new industrial development. these standards provide clear and quantifiable direction to ensure that future development maintains the unique character and high quality of design within the City of Chandler, while ensuring building form and scale are appropriate to the site. (2) Site layout: (a) Height, building setback, and lot coverage shall be regulated by the zoning district in which the property is located in. These regulations can be found in the City of Chandler Land Use and Zoning Code at the following links: Industrial Zoning Districts | Code Section Planned Industrial District (I-1) | 35-1503 General Industrial District (I-2) | 35-1603 Height and area regulations for lots located in Planned Area Development (PAD) zoning districts are established by the ordinance that adopted the PAD, which can be found in the development's zoning file. Zoning files are kept at the City of Chandler's Development Services Department. When industrial projects are next to or across an alley from a rear or side yard of single-family residential development: Industrial buildings shall be no closer than twenty-five (25) feet, plus one additional foot for each foot of height of the industrial building, from the residential property line. (b) Building orientation: 1. The building front shall be oriented to a public roadway or an internal primary drive for multi-building developments. 2. The office, showroom or other publicly accessible portions of the building shall be located or oriented in the building so as to be highly visible from a public roadway or the public realm. 3. A building located on a corner site shall be oriented to address both street frontages, and shall have enhanced landscaping and architectural design features such as street-facing windows and doors. 4. Warehouses shall be located to the side or rear of the building to minimize the visual impacts of warehousing/distribution activities, vehicle maneuvering areas, and back-of-house functions from the pedestrian and visitor experience. (c) Vehicular access and connectivity: 1. Public/visitor areas shall be separated from truck delivery and maneuvering areas. On multi-building projects, the primary driveway for the public and/or visitors shall provide the following: a. Variety of materials (e.g., texturized paving, colored pavement) b. Enhanced landscape palate compared to the balance of the site (d) Pedestrian connectivity: 1. An on-site walkway shall connect the main entry of each building or each primary entry to a public sidewalk on each street frontage of the site, and to any transit stop adjacent to the site. 2. A system of pedestrian walkways shall connect all buildings on a site to each other, to on-site automobile and bicycle parking areas, and to any on-site recreational or open-space areas or pedestrian amenities. 3. Textured paving treatments shall be provided at all on-site pedestrian crosswalks, and driveway entrances for a minimum of thirty (30) feet in length on-site. 4. Bus bay locations, where applicable, shall be integrated with pedestrian walkways that provide direct access to the property. 5. Perimeter sidewalks shall be provided in one of the following manners: a. Detached and separated from the curb by landscaping barrier; b. Attached to the curb; c. Entirely or partially meandering and detached and separated from the curb by landscaping barrier. 6. Perimeter sidewalks shall connect to existing perimeter sidewalks on abutting properties. 7. Perimeter sidewalks shall be not less than six (6) feet in width except that, in locations with anticipated heavier-than-normal pedestrian traffic, the zoning administrator may require these to be eight (8) feet in width. 8. Multi-building projects with three (3) or more buildings shall provide a minimum of two (2) functional outdoor amenities and/or communal areas for employees. Such amenities shall be located near building entrances or other focal points within the development where they will be convenient and comfortable for users. Outdoor amenities and communal area include, but are not limited to: a. Active recreational spaces such as sport courts, putting greens, etc. Active recreational spaces shall be located no closer than one hundred (100) feet to the property line of any property zoned for residential uses; b. Outdoor seating areas shaded by trees and/or structures such as trellises, pergolas, and canopies. (3) Building architecture: (a) Massing and articulation: 1. Horizontal off sets: Breaks in massing of at least two (2) feet in depth shall be provided for a minimum of twenty-five percent (25%) of a single building elevation through the use of varying setbacks, building entries, building face off set, or modulation of building facades. 2. Vertical variation: Change in rooflines of at least two (2) feet in height shall be provided for a minimum of twenty-five percent (25%) of a single building elevation through change in height and form. 3. The Zoning Administrator may accept minor departures from the horizontal off set and vertical variation requirements for the rear elevations of a building that are not visible from public rights-of-way and adjoining residential, commercial, or open spaces. (b) Architectural consistency: 1. Building architecture shall promote consistent architectural character and detail on all sides of the structure, including the continued use of building materials on each side. 2. If a subject site is located within a larger existing center or development, then the subject site shall be architecturally integrated with the larger center or development. To be considered architecturally integrated, the proposal shall provide the following at minimum: a. The predominant building color(s) (excluding accent colors) used on the proposed building shall match the predominant building color(s) found in the larger center. b. The predominant building materials used on the proposed building shall feature at least two (2) prominent building materials found in the larger center. c. The predominant roof form and roof materials on the proposed building shall use the same predominant roof form and roof materials found in the center. 3. Building features that are used for advertising or national image (corporate stylized architecture) shall be limited to a maximum of one accent color or material and shall meet one of the following: a. When the color or material is not found within the approved color palate for the larger center, then the color or material shall be limited to ten percent (10%) of a single building elevation. b. When the color or material is found within the approved color palate for the larger center, then the color or material shall be limited twenty percent (20%) of a single building elevation. Additional colors or materials may be considered if they are prominent building colors found within the approved color palate for the center. (c) Building materials: 1. Building materials shall be of high quality and durable. they include, but are not limited to: a. Brick b. Stone (natural or faux) c. Integral color, sand blasted or stain textured masonry d. Split-faced masonry units e. Tilt-up concrete panels f. Stucco/EIFS g. Architectural pre-finished metal 2. A generous amount of glazing shall be incorporated into the design of the buildings. Glazing shall be provided at the following percentages for each individual building elevation: a. Front elevations and other elevations that directly face a public roadway, freeway, or internal primary drive: Minimum 20% b. Side elevations that are visible from a public roadway, freeway, or an internal drive but not directly facing the roadway or drive: Minimum 10% c. Rear elevations that are visible from the public roadway, freeway or internal drive: Minimum 5% 3. At least three (3) facade materials shall be used in addition to glazing and accent features (e.g., fence panels, tile accents, trellises) as follows: a. Front elevation and other elevations that directly face a public roadway: A predominant material (maximum sixty percent (60%)) and two (2) additional materials (minimum forty percent (40%) combined) b. Side elevation: A predominant material (maximum 80%) and two (2) additional materials (minimum twenty percent (20%) combined) (d) Facade details: 1. Building entrances: a. Each principal building shall have clearly defined, highly visible primary entrances for occupants and patrons. Every primary entrance shall have a special emphasis when compared to the other portions of the building. This shall be accomplished by providing the three below enhanced design elements near the entrances: 1. Increased use and height of glazing, encompassing a minimum of seventy-five percent (75%) of the height of the building; 2. Raised parapets with a minimum increase in height of two (2) feet; 3. Canopies or porticos. b. In addition to the above required design elements, a minimum of two (2) additional enhanced design elements shall be provided near the entrances, including but not limited to: 1. Recesses/projections 2. Peaked roof forms 3. Arches 4. Integral planters or wing walls 5. Enhanced pedestrian surfaces c. When a building entrance is located at the corner of a building, the design elements incorporated into the entry shall wrap around the corner of the building. Design elements on each side of the corner entry shall span the same length of the building. d. Building entries shall be oriented toward the predominant public view, usually the street frontage. This allows the public to more easily determine where the front entrance is located and provides a more attractive street frontage. e. Large buildings which front multiple streets shall provide multiple entrances. 2. Solid covered canopies shall be provided at all pedestrian building entries at a minimum depth of four (4) feet. (e) Screening: 1. Any industrial development using outside storage area for equipment, vehicles or materials shall screen such area from view with a minimum six (6) foot masonry or concrete wall excluding approved gated openings. 2. Dismantling, servicing, repairing, etc., of vehicles and/or equipment shall be within completely enclosed buildings or within an area enclosed by a solid concrete, masonry, or similar material wall except for openings for ingress and egress which shall be furnished with solid gates. 3. Service bays shall meet all of the following screening requirements: a. Screening from adjacent properties zoned for residential uses shall meet the following requirements: 1. Bay doors located within one hundred (100) feet of an adjacent residential property line shall be oriented away from the adjacent use. 2. Bay doors located between one hundred (100) feet and six hundred (600) feet of an adjacent residential property line and oriented such that the bay doors would be visible from the adjacent use shall be screened with an intervening building or an eight (8) foot tall screen wall. The eight (8) foot tall screen wall shall not be located in the required building setback. b. Screening from adjacent streets shall be accomplished through the use of intervening building such that the bay doors are not visible from the street(s). Sites that are unable to screen service bays using an intervening building shall use at minimum one of the following methods: 1. Preferred method: Orient the building such that the bay doors are perpendicular to the abutting street. For corner lots, the bay doors shall be oriented perpendicular to the street with the highest functional street classification (i.e. arterial, collector, etc.) identified in the general plan. In the event that the street classifications are equivalent, the orientation creating the smallest noise impact on adjacent residential development shall be used. 2. Bay doors facing the street shall be setback at least two hundred (200) feet. 3. Bay doors less than two hundred (200) feet from an adjacent street and less than perpendicular to a street shall provide a solid six (6) foot masonry screen wall. The six (6) foot tall screen wall shall not be located in the required building setback. c. All stairways to upper levels shall be located within the building. d. Screen walls exceeding eighty (80) feet in length that are visible from street view, open space, or properties zoned for commercial or residential uses shall be broken up through the use of pilasters, and/or offsets in the alignment of the wall or fence. e. Truck courts shall be fully screened from street view, open space, and any surrounding properties zoned for commercial or residential uses through the use of at least one of the following methods: 1. Use of intervening buildings such that the entirety of the truck courts are not visible; 2. Use of solid eight (8) foot tall masonry or concrete screen wall(s) and opaque gate(s). f. When security fencing is required, it shall be provided as view fencing. View fencing may include a combination of masonry and view fencing, provided that at least the top sixty percent (60%) of the fencing is view fencing. g. The use of concertina wire or barbed wire is prohibited unless not visible from public view. (f) Interface with single-family area: When industrial projects are next to or across an alley from a rear or side yard of single-family residential development: 1. Second-story window balconies and other openings are allowed only when demonstrated to and approved by the Zoning Administrator that back yards of adjacent residences will not be visible from such balconies or openings by persons sitting or standing in the commercial buildings.
(Ord. No. 5142, § 2(Exh. A), 11-13-25)
Ask a question about Chandler law
Corpus searches the Chandler sections it holds and shows the ones that match, with their citations. Free, no sign-in.
