For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.2.13 — Commercial Waste Receptacles and Enclosures

Code of the City of Grand Rapids, Michigan (Supp. No. 70: codified through Ordinance No. 2026-08, enacted April 14, 2026) · Grand Rapids City Code § 5.2.13

Corpus is an independent public-information project, not the official City of Grand Rapids website. Stable reference: corpuslaw.us/code/ed8bf872-1338-4788-8bd6-89c153b1cd5c

Sec. 5.2.13. - Commercial Waste Receptacles and Enclosures.

A. Applicability. The requirements of this Section shall apply to all properties using a receptacle, other than a residential waste container, that is used for the purpose of waste removal, recycling, or reuse of household waste, household goods, clothing, or similar materials. B. Enclosure. 1. All outdoor waste, recycling and compost receptacles, including grease barrels, shall be enclosed on three (3) sides and screened. The fourth side of the enclosure shall consist of a gate, made of wood, vinyl, or other high quality material, as determined by the Director. If the waste receptacle is a dumpster, it shall have an enclosing lid or cover which shall remain closed when not in use. 2. Residential compost receptacles shall be subject to the provisions of Section 9.108 of the City Code. [image omitted; see the official code] 5.2.13. Waste Receptacles & Enclosures C. Materials. The enclosure shall be constructed of brick or decorative textured block wall to recognize the permanence of the structure, reduce maintenance requirements and lessen the opportunity for graffiti or vandalism. The enclosure shall be consistent with the building materials of the main building. Steel or concrete bollards shall be installed to assist in the positioning of dumpsters and to protect the enclosure. D. Size. The waste receptacle base shall be at least nine (9) feet by six (6) feet in area, constructed on six (6) inches of reinforced concrete pavement. The base shall extend six (6) feet beyond the waste receptacle pad or gate to support the front axle of a refuse vehicle. The enclosure shall have a minimum height of six (6) feet or one (1) foot above the height of the waste receptacle, whichever is greater. The enclosure shall have at least three (3) feet of space on each side of the waste receptacle. E. Placement. 1. Preferred placement. When possible, the back side of the waste receptacle enclosure should be placed against the building, which may act as one (1) side of the enclosure. 2. Front yard. Waste receptacles and enclosures shall not be placed in the front yard. 3. Rear and side yards. Waste receptacles and enclosures shall be in the rear or side yard and not closer than three (3) feet from the rear or side lot line, unless otherwise approved by the Director where no other practical location is present. 4. Residential use adjacent. Waste receptacles and enclosures shall be placed a minimum of twenty (20) feet from an adjacent residential use. 5. Landscape Buffer. A waste receptacle enclosure shall not be placed within a required landscape buffer area, as described in Section 5.11.12. F. Access. Waste receptacles shall be easily accessed by refuse vehicles without the potential to damage vehicles parked in designated parking spaces or interfering with the normal movement of vehicles on or off the site. G. Administrative Departure. An Administrative Departure for enclosure materials and the placement of an enclosure may be granted. In granting a waiver from the placement requirements, the Director shall take into consideration the proximity of adjacent residential structures, topography, natural features, existing screening or other barriers, and operational requirements for trash removal that would mitigate potentially adverse effects.

Ask a question about Grand Rapids law

Corpus searches the Grand Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.