Sec. 28-31. - Deletions and amendments to the 2021 International Existing Building Code.
1. Section 101.1. is deleted in its entirety and replaced with the following:
1.01.1 Title. These regulations shall be known as the Existing Building Code of the City of Denton, hereinafter referred to as "this code."
2. Section 103.1 is deleted in its entirety and replaced with the following:
103.1 Creation of agency. The Building Safety Department is hereby created and the executive official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code.
3. Section 112 Means of Appeal, is deleted in its entirety and replaced with the following:
112 HEALTH AND BUILDING STANDARDS COMMISSION
112.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official, code official, or fire marshal relative to the application and interpretation of the requirements of this Code and all other applicable codes of the City of Denton, there shall be a health and building standards commission.
112.2 Limitations on authority. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply or an equally good or better form of construction is proposed. The health and building standards commission shall not have authority to waive requirements of this code.
4. Section 202 Definitions, is amended to incorporate the amended definitions as follows:
EXISTING BUILDING. A building, structure, or space, with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; or a change of occupancy.
EXISTING STRUCTURE. A building, structure, or space, with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; or a change of occupancy.
5. Section 306.1. Scope, is deleted in its entirety and replaced with the following:
The provisions of Sections 306.1 through 306.7.16 apply to maintenance and repair, change of occupancy, additions and alterations to existing buildings, including those identified as historic buildings.
Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter.
6. Section 406.1 is deleted in its entirety and replaced with the following:
406.1 Material. Existing electrical wiring and equipment undergoing repair shall be allowed to be repaired or replaced with like material, in accordance with the requirements of NFPA 70.
7. Section 702.7 is deleted in its entirety and replaced with the following:
702.7 Materials and methods. New work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, National Electrical Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection joints, penetrations, and continuity of any element, component, or system in the building.
8. Section 802.5.1 is deleted in its entirety and replaced with the following:
802.5.1 Minimum requirement. Every portion of open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that is more than 30 inches (762 mm) above the floor or grade below and is not provided with guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided with guards.
8. Section 803.2.6 is deleted in its entirety and replaced with the following:
803.2.6 Supervision. Fire sprinkler systems required by this section shall be supervised by one of the following methods:
1. Approved central station system in accordance with NFPA 72.
2. Approved proprietary system in accordance with NFPA 72.
3. Approved remote station system of the jurisdiction in accordance with NFPA 72.
4. Where approved by the code official, approved local alarm service that will cause the sounding of an alarm in accordance with NFPA 72.
Exception: Supervision is not required where the Fire Code does not require such for new construction.
9. Section 1301.3.2 is deleted in its entirety and replaced with the following:
1301.3.2 Compliance with other codes. Buildings that are evaluated in accordance with this section shall comply with the International Fire Code.
(Ord. No. 22-662, § 1, 4-5-22)