§ 10-95 — Inspection and maintenance
Code of the Town of Gilbert, Arizona (Supp. No. 103: codified through Ordinance No. 2986, enacted June 9, 2026) · Gilbert Town Code § 10-95
Corpus is an independent public-information project, not the official City of Gilbert website. Stable reference: corpuslaw.us/code/ee447155-8942-47a4-a36b-d69dd49531a1
Sec. 10-95. - Inspection and maintenance.
(a) Duty of consumer. It shall be the duty of the consumer at premises on which backflow prevention assemblies required by this article are installed to have inspection, tests, maintenance and repair made in accordance with the following schedule, or more often where inspections indicate a need or are specified in the manufacturer's instructions, at the consumer's expense. (1) Fixed proper air gap separations shall be inspected at the time of installation and at least annually thereafter. (2) Double check valve assemblies shall be inspected and tested for tightness at time of installation and at least annually thereafter, and required service performed within 15 days. (3) Reduced pressure principle backflow prevention devices shall be tested at the time of the installation and at least annually or more frequently if recommended by the manufacturer, or the department. (4) All commercial pressure vacuum breakers shall be tested annually. (b) Testing. Testing shall be performed by a person who has been approved by the department. Proof of approval shall be in writing. Testing shall be in accordance with procedures described in section 9 of the Manual of Cross-Connection Control, Eighth Edition, USC-FCCHR (Los Angeles, California: June 1988), or, if the person doing the testing has been certified under the 9th Edition, the testing shall be performed in accordance with the procedures described in section 9 of the Manual of Cross-Connection Control, 9th Edition (LA CA, December, 1993). (c) Repairs. Whenever backflow prevention assemblies required by this article are found to be defective, they shall be repaired or replaced at the expense of the consumer within 45 days or as specified by the officer. (d) Alterations. Backflow prevention assemblies shall not be bypassed, made inoperative, removed or otherwise made ineffective without specific authorization by the department. (e) Rebuilding. All backflow prevention assemblies shall be rebuilt as determined by the officer. (f) Security. All backflow assemblies installed shall have a chain with a padlock from the first O.S. & Y. valve to the second O.S. & Y. valve, or an alarm system, or both. (g) Painting. All backflow assemblies shall be painted tan or a color to match the background. (h) Test cocks. Test cocks are to be used for testing only. Any unauthorized use is a violation of this article. All test cocks shall have plugs in place at all times, to be removed for testing only.
(Ord. No. 869, § I(7-14-8), 6-7-94)
Ask a question about Gilbert law
Corpus searches the Gilbert sections it holds and shows the ones that match, with their citations. Free, no sign-in.
