For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 33.218.140 — Standards for All Structures in the RM3, RM4, RX, C, CI, and E Zones

Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.218.140

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/ee93d8a1-a358-4671-bbc2-162928cf43a5

33.218.140 Standards for All Structures in the RM3, RM4, RX, C, CI, and E Zones

The standards of this section apply to development of all structures in RM3, RM4, RX, C, CI, and E zones. These standards also apply to exterior alterations in these zones. Applicants for development of new structures on sites where the uses are all residential can choose to meet all the standards of this section or all the standards of Section 33.218.110. Applicants for exterior alterations on sites where the uses are all residential can choose to meet all the standards of this section or all the standards of Section 33.218.130. A. Building placement and the street. Landscaping, an arcade, or a hard-surfaced expansion of the pedestrian path must be provided between a structure and the street. All street- facing elevations must meet one of the following options. Structures built to the street lot line are exempt from the requirements of this subsection. Where there is more than one street lot line, only those frontages where the structure is built to the street lot line are exempt from the requirements of this subsection. 1. Foundation landscaping option. All street-facing elevations must have landscaping along their foundation. This landscaping requirement does not apply to portions of the building facade that provide access for pedestrians or vehicles to the building. The foundation landscaping must meet the following standards: a. The landscaped area must be at least 3 feet wide; b. There must be at least one three-gallon shrub for every 3 lineal feet of foundation; and c. Ground cover plants must fully cover the remainder of the landscaped area. 2. Arcade option. All street-facing elevations must have an arcade that meets the following requirements: a. The arcade must be at least 6 feet deep between the front elevation and the parallel building wall; b. The arcade must consist of openings that are at least 6 feet wide and that run the full length of the street facing elevation; c. The arcade elevation facing a street must be at least 14 feet in height and at least 25 percent solid, but no more than 50 percent solid; and d. The arcade must be open to the air on three sides; none of the arcade's street facing or end openings may be blocked with walls, glass, lattice, glass block or any other material. 3. Hard-surface sidewalk extension option. The area between the building and the street lot line must be hard-surfaced for use by pedestrians as an extension of the sidewalk: a. The building walls may be set back no more than 10 feet from the street lot line; and b. For each 100 square feet of hard-surface area between the building and the street lot line at least one of the following amenities must be provided. Structures built within 2 feet of the street lot line are exempt from the requirements of this subparagraph: (1) A bench or other seating; (2) A tree; (3) A landscape planter; (4) A drinking fountain; or (5) A kiosk. c. Bicycle parking may be located in the area between a building and a street lot line. B. Improvements between buildings and pedestrian oriented streets. 1. Where the ground floor of a building is in commercial or residential uses, and the building has frontage on a transit street or City Walkway, or is in a Pedestrian District, the following standards must be met. Proposals required to meet this standard are exempt from the requirements of Subsection 33.218.140.A, Building Placement and the Street: a. A building wall that faces a transit street or City Walkway, or is in a Pedestrian District, must meet the base zone maximum street setback along 100 percent of the street lot line. Where no maximum street setback is specific in the base zone, the maximum street setback is 10 feet. Where the site has two frontages that are on a transit street or City Walkway, or is in a Pedestrian District, this standard must be met on both frontages. Where there are more than two such frontages, this standard must be met on any two frontages; b. The area between the building and an adjacent transit street, City Walkway, or street in a Pedestrian District, must be hard-surfaced for use by pedestrians as an extension of the sidewalk. Where the ground floor is in residential use, the area adjacent to the dwelling unit may be landscaped to an L1 standard of Chapter 33.248, Landscaping and Screening; and c. For each 100 square feet of hard-surface area between the building and the street lot line at least one of the following amenities must be provided. Structures built within 2 feet of the street lot line are exempt from the requirements of this subparagraph. (1) A bench or other seating; (2) A tree; (3) A landscape planter; (4) A drinking fountain; or (5) A kiosk. d. Bicycle parking may be located in the area between a building and a street lot line when the area is hard-surfaced. C. Reinforce the corner. On sites within a Pedestrian District or with at least two frontages on the corner where two City Walkways meet: 1. The primary structures must be within 10 feet of both street lot lines. Where a site has more than one corner, this requirement must be met on only one corner; 2. At least one of the street-facing walls must be at least 40 feet long; 3. The highest point of the building's street-facing elevations must be within 25 feet of the corner; 4. A main entrance must be on a street-facing wall and either at the corner, or within 25 feet of the corner; and 5. There is no parking within 40 feet of the corner. D. Residential buffer. Where a site zoned RM3, RM4, RX, CI, or E abuts or is across a street from an RF through RM1 zone, the following is required. Proposals in the Hollywood, Kenton, and Sandy Boulevard plan districts are exempt from this standard: 1. On sites that abut an RF through RM1 zone the following must be met: a. In the portion of the site within 25 feet of the lower density residential zone, the building height limits are those of the adjacent residential zone; and b. A 10-foot deep area landscaped to at least the L3 standard must be provided along any lot line that abuts the lower density residential zone. 2. On sites across the street from an RF through RM1 zone the following must be met: a. On the portion of the site within 15 feet of the intervening street, the height limits are those of the lower density residential zone across the street; and b. If the site is across a local service street from an RF through RM1 zone, a 5-foot deep area landscaped to at least the L2 standard must be provided along the property line across the local service street from the lower density residential zone. Vehicle access is not allowed through the landscaped area unless the site has frontage only on that local service street. Pedestrian and bicycle access is allowed, but may not be more than 6 feet wide. E. Building height. 1. Maximum height in RM3, RM4, RX, CI, C, and E zones. a. Generally. Structures in the RM3, RM4, RX, CI, C, and E zones may be up to 55 feet in height where allowed by the base zone; b. Where a site zoned RM3, RM4, RX or E abuts or is across a street from an RF through R2 zone, the maximum height is reduced as specified in Subsection D, above; c. New and replacement antennas are exempt from this standard if the antennas are located on an existing monopole, and the antennas do not project above the height of the monopole. 2. Minimum height. In C and E zones, primary buildings must be at least 16 feet in height. F. Main entrance. 1. Location of main entrance. The main entrance of the primary structure must face the street lot line. Where there is more than one street lot line, the entrance may face either of them or the corner. For residential developments there are the following exceptions: a. For buildings that have more than one main entrance only one entrance must meet this requirement. b. Entrances that face a shared landscaped courtyard, landscaped to at least the L1 General Landscaping standard, are exempt from this requirement. 2. Front porch at main entrances to residential. There must be a front porch at the main entrance to residential portions of a development, if the main entrance faces a street. If the porch projects out from the building it must have a roof. If the roof of a required porch is developed as a deck or balcony it may be flat. If the main entrance is to a single dwelling unit, the covered area provided by the porch must be at least 6 feet wide and 4 feet deep. If the main entrance is to more than one dwelling unit, the covered area provided by the porch must be at least 9 feet wide and 7 feet deep. G. Vehicle areas. 1. Access to vehicle areas and adjacent residential zones. Access to vehicle areas must be at least 20 feet from any adjacent residential zone. 2. Parking lot coverage. No more than 50 percent of the site may be used for vehicle areas. 3. Vehicle area screening. Where vehicle areas are across a local service street from an RM2, RM3, RM4, or RX zone, there must be a 6 foot wide landscaped area along the street lot line that meets the L3 standard of Chapter 33.248, Landscaping and Screening. Vehicle areas across a local service street from an RF through RM1 zone are subject to the standards of Subsection D., Residential Buffer, above. H. Foundation material. Plain concrete block or plain concrete may be used as foundation material if the foundation material is not revealed more than 3 feet above the finished grade level adjacent to the foundation wall. This subsection does not apply to sites in the EX zone within the St. Johns plan district. I. Exterior finish materials. 1. The standards of this paragraph must be met on all building facades. a. Plain concrete block, plain concrete, corrugated metal, plywood, composite materials manufactured from wood or other products, sheet pressboard, and horizontal shiplap or clapboard siding may not be used except as secondary finishes if they cover no more than 10 percent of each facade. b. Exception for sites in the EX zone within the St. Johns plan district. Plain concrete block, plain concrete, and corrugated metal are permitted as exterior finish materials in the EX zone in the St. Johns plan district. 2. Compatible exterior finish materials. Where there is an exterior alteration to an existing building, the exterior finish materials on the portion of the building being altered or added must visually match the appearance of those on the existing building. However, if the exterior finish materials on the existing building do not meet the standards of Paragraph I.1, any material that meets the standards of Paragraph I.1 may be used. J. Roof-mounted equipment. All roof-mounted equipment, including satellite dishes and other communication equipment, must be screened in one of the following ways. Solar energy systems are subject to paragraph K below, and exempt from this standard: 1. A parapet as tall as the tallest part of the equipment; 2. A screen around the equipment that is as tall as the tallest part of the equipment; 3. The equipment is set back from the street-facing perimeters of the building 4 feet for each foot of height of the equipment; or 4. If the equipment is a satellite dish or other communication equipment, it is added to the facade of a penthouse that contains mechanical equipment, is no higher than the top of the penthouse, is flush mounted, and is painted to match the facade of the penthouse. K. Rooftop solar energy systems. 1. Rooftop solar energy systems must meet the following requirements: a. On a flat roof. The solar energy system must be mounted flush or on racks, with the system or rack extending no more than 5 feet above the top of the highest point of the roof, not including the parapet. Solar energy systems must also be screened from the street by: (1) An existing parapet along the street-facing facade that is as tall as the tallest part of the solar energy system; or (2) Setting the solar energy system back from the street-facing roof edges. For each foot of height that the portion of the system projects above the parapet, or roofline when there is no parapet, the system must be set back 4 feet. b. On a pitched roof. The plane of the system must be parallel with the roof surface, with the system no more than 12 inches from the surface of the roof at any point, and set back 3 feet from the roof edge and ridgeline. 2. Photovoltaic roofing shingles or tiles may be directly applied to the roof surface. 3. Photovoltaic glazing may be integrated into windows or skylights. 4. Ground pole mounted solar energy systems are subject to the following additional standard: On sites that abut an RF through R2 zone, the system must be set back one foot for every one foot of height, from the lot line abutting the RF through R2 zone. L. Water cisterns. Above-ground cisterns for rainwater or greywater collection meet the following: 1. Cisterns with a capacity of more than 80 gallons, or racks of cisterns with a total capacity of more than 80 gallons, may not be attached to the front facade of the primary structure; and 2. Cisterns must either a. Match the color of the adjacent building wall, the color of the trim, or the color of the rain gutter; or b. Be screened by development, plantings, or fences so they are not visible from the street. M. Ground floor windows. Street-facing elevations must meet the standards of 33.130.230.B, Ground floor windows. As an alternative to providing ground floor windows, proposals in E zones may provide public art if the following conditions are met: 1. The area of the ground level wall that is covered by the art must be equal to the area of window that would have been required; 2. The artist and the specific work or works of art must be approved by the City Arts Program or its designee; and 3. The art must be composed of permanent materials permanently affixed to the building. Acceptable permanent materials include metal, glass, stone and fired ceramics. N. Distinct ground floor. This standard applies to buildings that have any floor area in non- residential uses. The ground level of the primary structure must be visually distinct from upper stories. This separation may be provided by: 1. A cornice above the ground level; 2. An arcade; 3. Changes in material or texture; or 4. A row of clerestory windows on the building's street facing elevation. O. Roofs. Buildings must have either: 1. A sloped roof with a pitch no flatter than 6/12; or 2. A roof with a pitch of less than 6/12 and a cornice that meets the following: a. There must be two parts to the cornice. The top part of the cornice must project at least 6 inches from the face of the building and be at least 2 inches further from the face of the building than the bottom part of the cornice. See Figure 218- 3; and b. The height of the cornice is based on the height of the building as follows: (1) Buildings 10 feet or less in height must have a cornice at least 12 inches high. (2) Buildings greater than 10 feet and less than 30 feet in height must have a cornice at least 18 inches high. (3) Buildings 30 feet or greater in height must have a cornice at least 24 inches high. P. Base of buildings. Buildings must have a base on all street-facing elevations. The base must be at least 2 feet above grade and be distinguished from the rest of the building by a different color or material. Q. Additional standards for historic resources. The following standards are additional requirements for conservation districts and conservation landmarks. 1. Zero setbacks. For structures where none of the floor area is in residential use, no setback is permitted from the street lot line. Sites that have more than one street lot line must meet this standard along two street lot lines. 2. Exterior siding. a. Where wood products are used for siding, the siding must be shingles, or horizontal siding, not shakes. b. Where horizontal siding is used, it must be shiplap or clapboard siding composed of wooden boards with a reveal of 3 to 6 inches, or vinyl or aluminum siding that is in a clapboard or shiplap pattern where the boards in the pattern are 6 inches or less in width. c. The siding material may not cover the window and door trim. 3. Building features to be retained. In RH zones the following building features on street- facing elevations must be retained. Building features that are not original to the building are exempt from this standard: a. Entrances; b. Front porches; c. Balconies; d. Bay windows; and e. Dormers. 4. Ground level glass. All glass in ground level street-facing windows and doors must be clear or ornamental stained glass. Restrooms may have reflective or opaque glass. 5. Clerestory windows. There must be clerestory windows above all windows and doors on the ground floor of street-facing elevations of buildings or parts of buildings with commercial uses. 6. Parapets. Flat roofs must be surrounded by a parapet at least 18 inches in height. 7. Arched windows in Russell Street. In the Russell Street Conservation District, all top floor windows on street-facing elevations must have an arch at the top of their window framing. 8. Red brick in Russell Street. In the Russell Street Conservation District, street-facing elevations must be red brick or a combination of block (basalt or cast stone) and red brick. Up to 20 percent of the facade may be stone or precast concrete. 9. Cast stone in Kenton. In the Kenton Conservation District new buildings in commercial/mixed use zones must have cast stone on their street facing elevations. At least 50 percent of the total exterior wall surface of these elevations must be cast stone. 10. Wood facades in Woodlawn. In the Woodlawn Conservation District, commercial buildings and commercial portions of mixed use buildings must have wood as their exterior finish material on their street facing elevations. 11. Facade height in Russell Street, Woodlawn, and Piedmont. In the Russell Street, Woodlawn and Piedmont Conservation Districts, the street-facing elevations of commercial and mixed use buildings must be at least 20 feet in height. 12. Woodlawn street pattern. Buildings may not be in the vacated portions of the angled street pattern in the Woodlawn Conservation District. 13. Rooftop solar energy systems. a. Rooftop solar energy systems in conservation districts must not increase the footprint of the structure, must not increase the peak height of the roof, and the system must be parallel to the slope of the roof; b. Solar energy systems may not be installed on a conservation landmark. 14. Photovoltaic glazing, roofing shingles, or tiles may not be installed on a conservation landmark.

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.