§ 15.18.030 — Undergrounding utility facilities required; exceptions
Henderson Municipal Code (Supp. No. 59: codified through Ordinance No. 4163, adopted June 16, 2026) · Henderson Municipal Code § 15.18.030
Corpus is an independent public-information project, not the official City of Henderson website. Stable reference: corpuslaw.us/code/ef9e0757-5e4b-43c4-b1b0-31f13488fcab
15.18.030 - Undergrounding utility facilities required; exceptions.
A. New or relocated utility facilities in the corporate boundaries of the city shall be located underground except as provided in subsection B. B. The following exceptions apply to the undergrounding requirements in subsection A.: 1. City equipment installed to the satisfaction of the director-PWPR or the director-PWPR's designee, including but not limited to traffic control devices, streetlight systems, public safety equipment, and SCADA systems. 2. Utility facilities transmitting electricity over 34,500 volts (a) after the utility obtains a conditional use permit in accordance with title 19, which permit, at a minimum, identifies the route, pole locations, and system design; or (b) that are located in a city-approved aboveground utility corridor and the route, pole locations, and system design are approved by the city in accordance with title 19. 3. The addition of new circuits, or oversizing of existing wires or cables, on an existing serviceable pole line to provide electrical service that serves additional customers, provided a replacement pole is no more than five percent or five feet taller and/or no more than ten percent larger in circumference in relation to the pole being replaced to accommodate that addition of new circuits, or oversizing of existing wires or cables, on that existing serviceable pole line. 4. Relocating a one-half mile section, or more, of an existing aboveground system of utility facilities if the utility obtains a permit from the city to perform the foregoing and installs approved poles; provided, however, that where the continuity of alignment is broken by the intersection with a major thoroughfare, freeway or expressway, by a street or railroad overpass or underpass, by a railroad crossing, by a change in alignment of a street or a pole line, or the end of a pole line, or by city-owned property, the PWPR department may require the replacement of a quarter-mile section with approved poles. 5. Radio antennae and wireless equipment for furnishing telecommunication service. 6. House service switch boxes, exposed conduit at buildings and electric meters. Telecommunications enclosed terminal blocks may be pedestal mounted or placed underground and shall be located as close to electric transformers as is practical. 7. Temporary aboveground utility facilities used or to be used in conjunction with (a) a construction project for a period of up to one year from the date the city approves the project plans or (b) a special event or temporary use for a period coterminous with the period identified in the permit issued by the city for such event or use provided that such period does not exceed six months. 8. Temporary aboveground utility facilities that are required for utility service after the director-PWPR approves in writing an application for installation of such temporary utility facilities. An application may be made to the director-PWPR for any of the following reasons: temporary unavailability of materials; emergency repairs to or replacement of the existing utility facilities as a result of malfunction or damage that will take more than 14 consecutive calendar days; or, accommodation of a city project. The applicant must obtain the director-PWPR's written approval prior to construction. If the director-PWPR does not approve an application and the applicant wishes to appeal that decision, then the applicant may appeal that decision to the city manager. The determination of the city manager to approve or disapprove the application shall be final. Any approval of the installation of temporary utility facilities shall be for a definite period of time and that time period may be extended in writing by the director-PWPR or city manager upon acceptable grounds. 9. Emergency service required because of malfunction or damage to any existing aboveground utility facilities. The utility may make such emergency connections as are required to maintain utility service or make the utility facilities safe and shall, within 72 hours after such construction, report the same to the director-PWPR if the emergency service is still in use. If the emergency service is to be used longer than 14 consecutive calendar days, then the utility shall make application for a temporary service as described in the immediately preceding subsection above. 10. Aboveground utility facilities that must be rebuilt, re-erected, replaced, and/or reconstructed because those utility facilities were damaged by a third party, were damaged by weather, or have deteriorated over time, provided the utility uses approved poles and/or utility facilities substantially similar to those being rebuilt, re-erected, replaced, and/or reconstructed. 11. Equipment appurtenant to underground utility facilities, such as surface-mounted transformers, surface-mounted switches, pedestal-mounted terminal boxes and meter cabinets, and concealed ducts. 12. Aboveground utility facilities that will be installed in areas approved from time to time by action of the city council upon recommendation of the planning commission or of the city manager.
(Ord. No. 3429, § 2, 8-15-2017)
Ask a question about Henderson law
Corpus searches the Henderson sections it holds and shows the ones that match, with their citations. Free, no sign-in.