For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 703.050 — Auxiliary support equipment development standards

Salem Revised Code, City of Salem, Oregon (Supp. No. 26: codified through Ordinance No. 10-26, adopted August 10, 2026) · Salem Revised Code § 703.050

Corpus is an independent public-information project, not the official City of Salem website. Stable reference: corpuslaw.us/code/efd793c6-f2f0-467d-8280-495842c2e9f3

Sec. 703.050. - Auxiliary support equipment development standards.

(a) Screening. (1) Equipment associated with support towers. Above ground auxiliary support equipment associated with a support tower shall be located inside the six-foot-high sight-obscuring fence or wall that complies with SRC 703.070(c). (2) Equipment associated with antennas on existing buildings. Auxiliary support equipment shall be located within or on top of the building or screened from the right-of-way and adjacent properties to the greatest extent practicable. Examples: within an underground vault, behind landscaping or a sight-obscuring fence, within an architectural element, or concealed to resemble a natural object such as a boulder. (3) Equipment associated with antennas on support structures other than existing buildings. Any auxiliary support equipment on support structures other than existing buildings must be screened from the right-of-way and adjacent properties and located within the support structure's footprint to the greatest extent practicable. Examples: placing the equipment within the interior of an adjacent building or structure, within an underground vault, behind landscaping or a sight-obscuring fence, or within an architectural element, or concealed to resemble a natural object such as a boulder. (4) Equipment associated with antennas on utility structures. (A) Equipment installed in right-of-way. Any auxiliary support equipment associated with one or more antennas on a utility structure and not installed on the utility structure shall be installed within an underground vault or in not more than one above ground cabinet with a combined height plus width plus depth no greater than 120 linear inches. (B) Equipment installed outside right-of-way. Any auxiliary support equipment installed outside the right-of-way shall be screened from the right-of-way and adjacent properties. Examples: placing the equipment within the interior of an adjacent building or structure, within an underground vault, behind landscaping or a sight-obscuring fence, or within an architectural element, or concealed to resemble a natural object such as a boulder. (C) Equipment attached to a utility structure. Equipment, other than optical fibers, wires or cables, attached to a utility structure shall: (i) Project no more than 18 inches from the surface of the utility structure; (ii) Be less than or equal to 24 inches in height; (iii) Be mounted a minimum of 15 feet above ground level on a utility structure located in the right-of-way between the sidewalk and the street improvement or a minimum of ten feet above ground level on a utility structure located in the right-of-way between the sidewalk and the property line abutting the right-of-way or a minimum of ten feet above ground level on a utility structure located outside the right-of-way. (b) Setbacks. Auxiliary support equipment installed above ground and outside the right-of-way shall be set back from all property lines according to the applicable standards in the underlying zone. (c) Vision clearance. Auxiliary support equipment installed above ground shall meet the vision clearance area requirements of SRC 76.170. (d) External cables and wires. All external cables and wires for auxiliary support equipment shall be placed in conduit or painted to match the tower, building, support structure, or utility structure, as applicable. (e) Coloration. (1) Equipment associated with support towers and support structures. All auxiliary support equipment shall be non-reflective and shall be painted natural earth or leaf tones or otherwise colored or surfaced so as to blend with the surrounding environment. (2) Equipment associated with utility structures. Equipment installed on a utility structure shall be non-reflective and painted, coated or given a surface application that is identical to the color and surface texture of the utility structure. Other equipment shall be non-reflective and painted natural earth or leaf tones or otherwise colored or surfaced so as to blend with the surrounding environment. (f) Lighting. Motion detecting security lighting is allowed for auxiliary support equipment, but shall be the minimum necessary to secure the auxiliary support equipment, shall not illuminate adjacent properties in excess of 0.4 footcandles measured directly beneath the security lighting, at ground level, and shall be shielded to prevent direct light from falling on adjacent properties. (g) Undergrounding required. Auxiliary support equipment installed in the right-of-way in a historic district or in the right-of-way adjacent to a historic district or historic resource or in the right-of-way where all other utilities are required to be placed underground shall be placed underground.

(Prior Code, § 703.050; Ord. No. 24-13)

Ask a question about Salem law

Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.